Содержание RLM series

Страница 1: ...RLM series User Guide RS232 commands R5976884 02 04 04 2006 ...

Страница 2: ...Barco nv Events Noordlaan 5 B 8520 Kuurne Phone 32 56 36 89 70 Fax 32 56 36 88 24 E mail sales events barco com Visit us at the web www barco com Printed in Belgium ...

Страница 3: ...nimum Contrast Read 24 2 7 6 Maximum Contrast Read 24 2 7 7 Brightness increment 25 2 7 8 Brightness decrement 26 2 7 9 Brightness Write 26 2 7 10 Brightness Read 27 2 7 11 Minimum Brightness Read 27 2 7 12 Maximum Brightness Read 28 2 7 13 Saturation increment 29 2 7 14 Saturation decrement 29 2 7 15 Write Saturation 30 2 7 16 Saturation Read 30 2 7 17 Minimum Saturation Read 31 2 7 18 Maximum Sa...

Страница 4: ...witching mode Write 74 2 36 Switching mode Read 75 2 37 Filmmode detection Increment Decrement 76 2 38 Filmmode detection Write 77 2 39 Filmmode detection Read 77 2 40 Autoimage execute 78 2 41 Blanking 79 2 41 1 Blanking Reset 80 2 41 2 Blanking enable Write 80 2 41 3 Blanking enable Read 80 2 41 4 Blanking Write 81 2 41 5 Blanking Read 82 2 41 6 Blanking Increment 83 2 41 7 Blanking Decrement 84...

Страница 5: ...2 3 12 12 Window Y position Increment 122 3 12 13 Window size Decrement 123 3 12 14 Window X position Decrement 123 3 12 15 Window Y position Decrement 123 3 13 Automatic startup Write 123 3 14 Automatic startup Read 124 3 15 Startup screen Write 125 3 16 Startup screen Read 126 3 17 Input balance 127 3 17 1 Input black balance Increment 127 3 17 2 Input black balance Decrement 128 3 17 3 Input bl...

Страница 6: ...filter Write 154 3 31 26 Comb filter Read 155 3 31 27 Minimum Maximum comb filter Read 156 3 31 28 Horizontal sync polarity Increment Decrement 156 3 31 29 Minimum Maximum Horizontal sync polarity Read 156 3 31 30 Horizontal sync polarity Read 157 3 31 31 Horizontal sync polarity Write 157 3 31 32 Sync locking Increment Decrement 157 3 31 33 Minimum Maximum Horizontal Sync locking Read 158 3 31 34...

Страница 7: ...data transfer will take place Projector address The projector address defines the address of the computer the projector wants to talk to in case of transmission or the address of the projector that answers in case of reception The maximum number of projectors that can be addressed by one computer is 256 Command byte s There is at least one command byte to define the action to be performed Commands...

Страница 8: ...s for more information about this see the EOP command Note Any command byte data byte or checksum byte that equals x80 xfe xff has to be converted 1 Transmission instead of x80 send x80 followed by x00 instead of xfe send x80 followed by x7e instead of xff send x80 followed by x7f 2 Reception replace x80 followed by x00 with x80 replace x80 followed by x7e with xfe replace x80 followed by x7f with...

Страница 9: ...here is no parity bit used to perform error checking Stop Bits One stop bit is used to define the end of a character 1 4 Hardware Overview Female D9 pin connector labelled RS232 IN used to connect the projector with the computer Pin out of the D9 connector Pin Name Full Name 1 CD Carrier Detect 2 RxD Received Data 3 TxD Transmitted Data 4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set ...

Страница 10: ...9 male Image 1 1 connection IBM PC or compatible projector 1 HSKo 2 HSKi 3 TxD 4 GND 5 RXD 6 TXD 7 n c 8 RXD 4 DTR 8 CTS 3 TxD 5 GND 2 RxD DIN mini 8 D9 male Image 1 2 connection MAC projector Signal levels Following table gives the signal levels corresponding to the different states State Voltage Off 1 9V On 0 9V 8 R5976884 RLM SERIES 04 04 2006 ...

Страница 11: ...l language string A Pascal language string consists of one or more characters The first character of the string contains the length of the string Therefore a Pascal language string is limited to 255 characters Pascal string Hello world length x0b h x68 e x65 l x6c l x6c o x6f x20 w x77 o x6f r x72 l x6c d x64 C language string A C language string consists of one or more characters The last charact...

Страница 12: ... the file none c00 file which is loaded when no signal is applied 5 yzz is a unique combination In other words no two files can exist with the same extension yzz To specify more than one file you can use the question mark and wildcard character for x y and z or any other character This wildcard character can represent any possible character on a particular location This wildcard character can repr...

Страница 13: ...anual is divided in two parts the first part contains the basic elementary commands while the second part gives an overview of the available advanced commands Some commands are illustrated with an example R5976884 RLM SERIES 04 04 2006 11 ...

Страница 14: ...1 Serial communications Basics 12 R5976884 RLM SERIES 04 04 2006 ...

Страница 15: ...ON OFF Write Show Native resolution ON OFF Read Full screen representation ON OFF Write Full screen representation ON OFF Read Keystone Write Keystone Read Lamp commands Image files Color temperature Standby Timer Write Standby Timer Read Switching mode Write Switching mode Read Filmmode detection Increment Decrement Filmmode detection Write Filmmode detection Read Autoimage execute Blanking 2 1 E...

Страница 16: ...ector type the returned string is a Pascal language string Command Command 0 x6b Returned Data Data 0 byLength 1 byte describing the length of the string Data 1 strDeviceType pascal language string describing the device type An example of device type is RLM 2 2 2 Projector s Software type Read Description Reads the Projector s Software type the returned string is a Pascal language string Command C...

Страница 17: ...l number the returned string is a Pascal language string Command Command 0 x61 Returned Data Data 0 x07 length of the serial number 7 characters Data 1 string of length 7 2 2 5 Projector s runtime Read Description Reads the Projector s runtime in seconds Command Command 0 x62 Returned Data unsigned double word 4 bytes Data 0 msb Data 1 Data 2 Data 3 lsb 2 2 6 Projector address Write Description Wr...

Страница 18: ...07 Stop xff 2 2 7 Projector language Read Description Reads the active language for the projector Command Command 0 x71 Returned Data Data 0 unsigned byte byte value language 0 English 1 Français 2 Deutsch 3 Español 4 Japanese 5 Chinese Example reads the active language being Français Transmit Start xfe Projector address x01 Command 0 x71 Checksum x72 Stop xff 16 R5976884 RLM SERIES 04 04 2006 ...

Страница 19: ...Data 0 x01 Checksum x73 Stop xff 2 2 8 Projector language Write Description Sets a new language for the projector Command Command 0 x70 Data Data 0 unsigned byte byte value language 0 English 1 Français 2 Deutsch 3 Español 4 Japanese 5 Chinese Example Sets the language to Français Transmit Start xfe Projector address x01 Command 0 x70 Data 0 x01 R5976884 RLM SERIES 04 04 2006 17 ...

Страница 20: ... 0 x75 Data string C language string possible string values 9600 19200 38400 57600 115200 2 3 RCU commands Description Simulation of the RCU codes sent by the RCU remote control For all commands see RCU commands page 165 Command Command 0 x30 Data Data 0 byIRcode 1 byte representing the RC5 code of the function to be executed Wrepeat optional word 2 bytes representing the duration 18 R5976884 RLM ...

Страница 21: ...mmand 0 x65 Checksum x66 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 2 5 Projector s Status Read Description Reads the Projector s Status Command Command 0 x67 Returned Data Data 0 unsigned byte bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 Not used Not used Cool down cycle active 0 inactive 1 Not used Not used Not used Textbox ON 1 OFF ...

Страница 22: ...box is on cool down cycle is inactive Transmit Start xfe Projector address x01 Command 0 x67 Checksum x68 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Awnser Start xfe Projector address x01 Command 0 x67 Data 0 x23 Checksum x8b Stop xff 2 6 Lens commands 2 6 1 Lens shift Description Shifts the lens down or up depending on th...

Страница 23: ...ives the Zoom direction in out 0 out 1 in 2 6 3 Lens Focus Description To Focus the image Command Command 0 xf4 Command 1 x83 Data Data 0 byDirection 1 byte 0 1 2 7 Picture setting 2 7 1 Contrast Increment Description Increments the contrast by one Command Command 0 x22 Command 1 x01 Example Increment contrast of a projector with address x01 by one Transmit Start xfe Projector address x01 Command ...

Страница 24: ... new contrast value to the projector Command Command 0 x20 Command 1 x01 Data Data 0 contrast value Data 0 unsigned byte Example Writes a new contrast value of x20 to the projector Transmit Start xfe Projector address x01 Command 0 x20 Command 1 x01 Data x20 Checksum x42 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 22 R5976884 RLM SERIES 04 04 2006 ...

Страница 25: ... Example Reads the actual contrast value of the projector the awnser being x20 Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x01 Checksum x23 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x21 Command 1 x01 Data 0 x20 Checksum x43 Stop xff R5976884 RLM SERIES ...

Страница 26: ... the awnser being x00 Transmit Start xfe Projector address x01 Command 0 x26 Command 1 x01 Checksum x28 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x26 Command 1 x01 Data 0 x00 Checksum x28 Stop xff 2 7 6 Maximum Contrast Read Description Reads the Maximum range contrast valu...

Страница 27: ...ress x01 Command 0 x27 Command 1 x01 Checksum x29 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x27 Command 1 x01 Data 0 x64 Checksum x8d Stop xff 2 7 7 Brightness increment Description Increments the Brightness by one Command Command 0 x22 Command 1 x02 R5976884 RLM SERIES 04 ...

Страница 28: ...the projector Command Command 0 x20 Command 1 x02 Data Data 0 contrast value value unsigned byte Example Writes a new Brightness value of x20 to the projector Transmit Start xfe Projector address x01 Command 0 x20 Command 1 x02 Data x20 Checksum x43 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 26 R5976884 RLM SERIES 04 04 2006 ...

Страница 29: ...r being x20 Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x02 Checksum x24 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x21 Command 1 x02 Data 0 x20 Checksum x44 Stop xff 2 7 11 Minimum Brightness Read Description Reads the minimum range Brightness value of ...

Страница 30: ...and 0 x26 Command 1 x02 Checksum x29 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x26 Command 1 x02 Data 0 x00 Checksum x29 Stop xff 2 7 12 Maximum Brightness Read Description Reads the Maximum range Brightness value of the projector Command Command 0 x27 Command 1 x02 28 R597...

Страница 31: ...p xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x27 Command 1 x02 Data 0 x64 Checksum x8e Stop xff 2 7 13 Saturation increment Description Increments the saturation by one Command Command 0 x22 Command 1 x03 2 7 14 Saturation decrement Description Decrements the Saturation by one R5...

Страница 32: ...value unsigned byte Example Writes a new Brightness value of x20 to the projector Transmit Start xfe Projector address x01 Command 0 x20 Command 1 x03 Data x20 Checksum x44 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 2 7 16 Saturation Read Description Reads the actual Saturation value of the projector 30 R5976884 RLM SERIES 04 04 2...

Страница 33: ...0 x21 Command 1 x03 Checksum x25 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x21 Command 1 x03 Data 0 x20 Checksum x45 Stop xff 2 7 17 Minimum Saturation Read Description Reads the minimum range Saturation value of the projector Command Command 0 x26 Command 1 x03 R5976884 RL...

Страница 34: ...ctor address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x26 Command 1 x03 Data 0 x00 Checksum x30 Stop xff 2 7 18 Maximum Saturation Read Description Reads the Maximum range Saturation value of the projector Command Command 0 x27 Command 1 x03 Returned Data Data 0 Maximum Saturation value Example Reads the Maximum Saturation value...

Страница 35: ...0 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x27 Command 1 x03 Data 0 x7f Checksum xaa Stop xff 2 7 19 Tint increment Description Increments the Tint by one Command Command 0 x22 Command 1 x04 2 7 20 Tint decrement Description Decrements the Tint by one Command Command 0 x23 Command 1 x04 R5976884 RLM SERIES 04 04 2006 33 ...

Страница 36: ...int value of x20 to the projector Transmit Start xfe Projector address x01 Command 0 x20 Command 1 x04 Data 0 x00 Data 1 x20 Checksum x45 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 2 7 22 Tint Read Description Reads the actual Tint value of the projector Command Command 0 x21 Command 1 x04 34 R5976884 RLM SERIES 04 04 2006 ...

Страница 37: ...m x26 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x21 Command 1 x04 Data 0 x00 Data 1 x20 Checksum x46 Stop xff 2 7 23 Minimum Tint Read Description Reads the minimum range Tint value of the projector Command Command 0 x26 Command 1 x04 Returned Data signed word R5976884 RLM ...

Страница 38: ...acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x26 Command 1 x04 Data 0 xff Data 1 x4c Checksum x76 Stop xff 2 7 24 Maximum Tint Read Description Reads the Maximum range Tint value of the projector Command Command 0 x27 Command 1 x04 Returned Data signed word Data 0 msb Data 1 lsb 36 R5976884 RL...

Страница 39: ...ledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x27 Command 1 x04 Data 0 x00 Data 1 xb4 Checksum xe0 Stop xff 2 7 25 Gamma increment Description Increments the Gamma by one Command Command 0 x22 Command 1 x70 2 7 26 Gamma decrement Description Decrements the Gamma by one R5976884 RLM SERIES 04 04 2006 ...

Страница 40: ...ata 0 unsigned byte Example Writes a new Gamma value of x11 to the projector Transmit Start xfe Projector address x01 Command 0 x20 Command 1 x70 Data x11 Checksum xa2 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 2 7 28 Gamma Read Description Reads the actual Gamma value of the projector 38 R5976884 RLM SERIES 04 04 2006 ...

Страница 41: ...0 x21 Command 1 x70 Checksum x92 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x21 Command 1 x70 Data 0 x11 Checksum xa3 Stop xff 2 7 29 Minimum Gamma Read Description Reads the minimum range Gamma value of the projector Command Command 0 x26 Command 1 x70 R5976884 RLM SERIES 0...

Страница 42: ...Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x26 Command 1 x70 Data 0 x10 Checksum xa7 Stop xff 2 7 30 Maximum Gamma Read Description Reads the Maximum range Gamma value of the projector Command Command 0 x27 Command 1 x70 Returned Data Data 0 Maximum Gamma value Example Reads the Maximum Gamma value of the project...

Страница 43: ...Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x27 Command 1 x70 Data 0 x1c Checksum xb4 Stop xff 2 7 31 Phase increment Description Increments the Phase by one Command Command 0 x22 Command 1 x06 2 7 32 Phase decrement Description Decrements the Phase by one Command Command 0 x23 Command 1 x06 R5976884 RLM SERIES 04 04 2006 41 ...

Страница 44: ...of x1a to the projector Transmit Start xfe Projector address x01 Command 0 x20 Command 1 x06 Data x1a Checksum x41 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 2 7 34 Phase Read Description Reads the actual Phase value of the projector Command Command 0 x21 Command 1 x06 Returned Data Data 0 Phase value 42 R5976884 RLM SERIES 04 04 ...

Страница 45: ... Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Answer Start xfe Projector address x01 Command 0 x21 Command 1 x06 Data 0 x1a Checksum x42 Stop xff 2 7 35 Minimum Phase Read Description Reads the minimum range Phase value of the projector Command Command 0 x26 Command 1 x06 Returned Data Data 0 minimum Phase value Example Reads the minimum Phase value of the projector the awnser being x...

Страница 46: ... Start xfe Projector address x01 Command 0 x26 Command 1 x06 Data 0 x00 Checksum x33 Stop xff 2 7 36 Maximum Phase Read Description Reads the Maximum range Phase value of the projector Command Command 0 x27 Command 1 x06 Returned Data Data 0 Maximum Phase value Example Reads the Maximum Phase value of the projector the awnser being x1f Transmit Start xfe Projector address x01 Command 0 x27 44 R597...

Страница 47: ...xfe Projector address x01 Command 0 x27 Command 1 x06 Data 0 x1f Checksum x4d Stop xff 2 8 Menu Exit Description Exits all the menus goes back to the operational mode Command Command 0 x42 Command 1 x01 Example Exits all the menu of a projector with address x01 Transmit Start xfe Projector address x01 Command 0 x42 Command 1 x01 Checksum x44 Stop xff R5976884 RLM SERIES 04 04 2006 45 ...

Страница 48: ... BNC s 2 D15 3 Composite video 4 SVideo 5 DVI 6 Firewire 7 SDI 8 IQ PC For more info about the input configurations see the projector s Owner s manual Data 1 byMode for BNC s and D15 the data byte gives the type of signal present on the BNC s D15 Byte value Mode 0 RGBHV 1 RGBCS analog4 2 RGBCS digital 3 RGsB 100 x 64 PrYPb 101 x 65 RGB video 102 x 66 RGSB video 4 the signal present on the Cs signa...

Страница 49: ...ted the mode is automaticaly detected 2 10 Scanned inputs read Description read the scanned inputs and returns the type of source signal present Command Command 0 x39 Command 1 x01 Returned Data 10 unsigned words see chapter 1 Serial communications Basics Data words page 6 Data word scanned input possible sources Wvalue wValue1 BNC RED 0 none 1 RED 2 Pr 3 S VID chr 4 VideoR wValue2 BNC GREEN 0 non...

Страница 50: ...11 Scan inputs Description Scans the inputs the results sources can be read using the scanned inputs read command Command Command 0 x39 Command 1 x02 Command 2 x00 2 12 File Load Description Loads a specific file Command Command 0 xbd Command 1 x82 Data File name no wild cards allowed Example Load a file named test c05 on projector with address 01 Transmit Start xfe Projector Address x01 Command 0...

Страница 51: ...hecksum x07 Stop xff 2 13 Orientation Write Description Writes the orientation to the projector Command Command 0 x20 Command 1 x24 Data Data 0 unsigned byte byte value x00 rear table x40 front table x80 front ceiling xc0 rear ceiling Example Set the orientation to front table Transmit Start xfe Projector address x01 Command 0 x20 Command 1 x24 Data 0 x40 R5976884 RLM SERIES 04 04 2006 49 ...

Страница 52: ... projector Command Command 0 x21 Command 1 x24 Returned Data Data 0 unsigned byte byte value x00 rear table x40 front table x80 front ceiling xc0 rear ceiling Example Read the orientation being x40 front table Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x24 Checksum x46 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 50 R5976884 RLM SER...

Страница 53: ... xff 2 15 Shutter Write Description Activates the shutter Command Command 0 x20 Command 1 x42 Data Data 0 unsigned byte byte value x00 CLOSE x01 OPEN Example opens the shutter Transmit Start xfe Projector address x01 Command 0 x20 Command 1 x42 Data 0 x01 Checksum x64 Stop xff Receive acknowledge Start xfe Projector address x01 R5976884 RLM SERIES 04 04 2006 51 ...

Страница 54: ...42 Returned Data Data 0 unsigned byte byte value x00 CLOSE x01 OPEN Example Read the shutter being x01 open Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x42 Checksum x64 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive awnser Start xfe Projector address x01 52 R5976884 RLM SERIES 04 04 2006 ...

Страница 55: ...nd Command 0 x20 Command 1 x23 Data Data 0 unsigned byte byte value x00 OFF x01 ON Example activate the Freeze function Transmit Start xfe Projector address x01 Command 0 x20 Command 1 x23 Data 0 x00 Checksum x44 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff R5976884 RLM SERIES 04 04 2006 53 ...

Страница 56: ...x01 ON Example Reads the Freeze function being x00 OFF Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x23 Checksum x45 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive awnser Start xfe Projector address x01 Command 0 x21 Command 1 x23 Data 0 x00 Checksum x45 Stop xff 54 R5976884 RLM SERIES 04 04 2006 ...

Страница 57: ...o ON Example Enables the logo Transmit Start xfe Projector address x01 Command 0 xf1 Command 1 x81 Data 0 x01 Checksum x74 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 2 20 Background Write Description Sets a particular background Command Command 0 x20 Command 1 x7B R5976884 RLM SERIES 04 04 2006 55 ...

Страница 58: ... x7b Checksum x9c Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 2 21 Background Read Description Reads the actual background Command Command 0 x21 Command 1 x7b Returned Data Data 0 unsigned byte byte value x00 Logo x01 Blue x02 Black Example Reads the actual background being x00 Logo 56 R5976884 RLM SERIES 04 04 2006 ...

Страница 59: ...mmand 1 x06 Checksum x07 Stop xff Receive awnser Start xfe Projector address x01 Command 0 x21 Command 1 x7b Data 0 x00 Checksum x9d Stop xff 2 22 Aspect ratio Write Description Sets the Aspect ratio Command Command 0 x20 Command 1 x0b Data Data 0 unsigned byte byte value x00 Auto x01 4 3 x02 5 4 x03 16 9 Example Sets the aspect ratio to 4x3 R5976884 RLM SERIES 04 04 2006 57 ...

Страница 60: ...nd 1 x06 Checksum x07 Stop xff 2 23 Aspect Ratio Read Description Reads the actual Aspect Ratio Command Command 0 x21 Command 1 x0b Returned Data Data 0 unsigned byte byte value 0 Auto 1 4 3 2 5 4 3 16 9 Example Read the PiP window which has the focus result x01 4 3 Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x0b Checksum x2d Stop xff 58 R5976884 RLM SERIES 04 04 2006 ...

Страница 61: ...m x2e Stop xff 2 24 Show Native resolution ON OFF Write Description Enable disables the native resolution function Command Command 0 x20 Command 1 xaf Sent Data Data 0 one byte 0 OFF 1 ON 2 25 Show Native resolution ON OFF Read Description Reads whether the native resolution function is enabled or not Command Command 0 x21 Command 1 xaf Reaturned Data Data 0 one byte 0 OFF 1 ON R5976884 RLM SERIES...

Страница 62: ...on Reads whether the Full screen representation is enabled or not Command Command 0 x21 Command 1 xae Reaturned Data Data 0 one byte 0 OFF 1 ON 2 28 Keystone Write Description Adjusts the keystone Command Command 0 x20 Command 1 x50 Data Signed word representing the keystone value Data 0 msb Data 1 lsb Example Sets the keystone to 0 Transmit Start xfe Projector address x01 Command 0 x20 Command 1 ...

Страница 63: ...Description Reads the actual Keystone value Command Command 0 x21 Command 1 x50 Returned Data signed word Data 0 MSB Data 1 LSB Example Reads the actual keystone value being x00 Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x50 Checksum x72 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 R5976884 RLM SERIES 04 04 2006 61 ...

Страница 64: ... Mode Write Lamp Mode Read Lamp Status Read Lamp Warning Read Lamp runtime Read Lamps Serial number Read 2 30 1 Lamp Mode Write Description Writes the Lamp mode to the projector Command Command 0 x20 Command 1 x0c Data Data 0 unsigned byte data byte value 0 Single mode 1 Dual mode Example Write the mode x00 single mode to the projector Transmit Start xfe Projector address x01 62 R5976884 RLM SERIE...

Страница 65: ...on Reads the actual Lamp mode of the projector Command Command 0 x21 Command 1 x0c Returned Data Data 0 unsigned byte data byte value 0 Single mode 1 Dual mode Example Reads the actual Lamp mode of the projector the awnser being x00 single mode Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x0c Checksum x44 Stop xff Receive acknowledge Start xfe Projector address x01 R5976884 RLM...

Страница 66: ...d Command 0 x21 Command 1 x0d Returned Data Data 0 Lamp Mode unsigned byte see Lamp Mode Read page 63 Data 1 Active lamp s unsigned byte see following table Lamp byte Hex Lamp1 0001 x01 Lamp2 0010 x02 Lamp1 Lamp2 0011 x03 Table 2 209 Lamp status active lamps table Example Reads the actual Lamp Status of the projector the awnser being x01 Lamp1 in single mode Transmit Start xfe Projector address x0...

Страница 67: ...iption Reads the actual Lamp Warning setting of the projector Command Command 0 x21 Command 1 x0e Returned Data Unsigned word composed of 2 bytes see chapter 1 Serial communications Basics Data words page 6 Data 0 first byte msb Data 1 second byte lsb Example Reads the actual Lamp warning setting of the projector the awnser being x1E 30 hours Transmit Start xfe Projector address x01 Command 0 x21 ...

Страница 68: ... lamp1 or lamp2 runtime to be read is given in the data field Command Command 0 x64 Data Data 0 unsigned byte data value 1 lamp1 2 lamp2 Returned Data Data 0 unsigned byte 1 lamp1 2 lamp2 unsigned double word 4 bytes representing the runitme see chapter 1 Serial communications Basics Data words page 6 Data 1 msb Data 2 Data 3 Data 4 lsb 2 30 6 Lamps Serial number Read Description Reads the Lamps S...

Страница 69: ...ctory If the necessary file is a standard file then strFile name should be Standard HD_1080 60 xml FileData data ASCII coded in XML format representing the file Example of FileData for the HD_1080P 60 xml file xml version 1 0 encoding UTF 8 ImageFile FileSelection InputLayer SourceType LineDuration Discrepancy 220 Unit ns 14840 LineDuration TotalLines Discrepancy 1 1118 TotalLines Interlaced no In...

Страница 70: ... used to specify the filenames Command Command 0 xc0 Send Data strFilemask1 strFilemaskN Returned Data strFilename1 string of the C string type representing the 1st filename strFilenameN string of the C string type representing the Nth filename 2 31 4 Active files list read Description This command reads a list of the active image files from the projector Command Command 0 xc5 Returned Data strFil...

Страница 71: ... one Command 0 x22 Command 1 x43 Increments the Blue color temperature by one Command 0 x22 Command 1 x44 Example Increment Red color temperature of a projector with address x01 by one Transmit Start xfe Projector address x01 Command 0 x22 Command 1 x43 Checksum x66 Stop xff 2 32 2 Color temperature Red Blue Decrement Description Decrements the Red Blue Color temperature by one Command Decrement t...

Страница 72: ...1 x43 Blue color temperature Command 0 x20 Command 1 x44 Data Unsigned word 2byte msb lsb see chapter 1 Serial communications Basics Data words page 6 Data 0 unsigned byte msb Data 1 unsigned byte lsb 2 32 4 Color temperature Red Bleu Read Description Reads the color temperature setting for the different colortemperatures from the projector Commands reads Red color temperature Command 0 x21 Comman...

Страница 73: ...re Read Description Reads the actual preset color temperature value from the projector Commands Command 0 x21 Command 1 x45 Returned Data Data 0 unsigned byte data values x00 projector white x20 broadcast x36 Film x41 Video x5D Computer xff custom Example Reads the actual preset color temperature of the projector the awnser being x00 projector white Transmit Start xfe Projector address x01 Command...

Страница 74: ...ription Adjusts the Standby Timer in a range from 180 to 3600 Command Command 0 x20 Command 1 x98 Data Unsigned word representing the standby time value Data 0 msb Data 1 lsb range 180 to 3600 seconds 0 seconds Standby timer OFF Example Sets the standby time to 400 Transmit Start xfe Projector address x01 Command 0 x20 Command 1 x98 Data 0 x01 Data 1 x90 Checksum x4a Stop xff 72 R5976884 RLM SERIE...

Страница 75: ...eturned Data Unsigned word representing the standby time value Data 0 msb Data 1 lsb range 180 to 3600 seconds 0 seconds Standby timer OFF Example Reads the actual standby timer value being x00 Timer OFF Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x98 Checksum xba Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff R59...

Страница 76: ...mand 0 x20 Command 1 x9a Data Data 0 unsigned byte Byte value Switching mode x01 Seamless x02 Box in x03 Box out x04 shift in left x05 shift in right x06 shift in top x07 shift in bottom x08 vertical curtain open x09 vertical curtain close x0a Horizontal curtain open x0b Horizontal curtain close x0c Fade in out Example Set the switching mode to seamless Transmit Start xfe Projector address x01 74 ...

Страница 77: ...scription Reads the Switching Mode of the projector Command Command 0 x21 Command 1 x9a Returned Data Data 0 unsigned byte Byte value Switching mode x01 Seamless x02 Box in x03 Box out x04 shift in left x05 shift in right x06 shift in top x07 shift in bottom x08 vertical curtain open x09 vertical curtain close x0a Horizontal curtain open x0b Horizontal curtain close x0c Fade in out R5976884 RLM SE...

Страница 78: ...dress x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Awnser Start xfe Projector address x01 Command 0 x21 Command 1 x9a Data 0 x01 Checksum xbd Stop xff 2 37 Filmmode detection Increment Decrement Description Increments decrements the Filmmode detection setting on off Commands increment Command 0 x22 Command 1 xa1 decrement command 0 x23 command 1 xa1 76 R5976884 RLM SERIES 04 04 20...

Страница 79: ...s the Filmmode detection Transmit Start xfe Projector address x01 Command 0 x20 Command 1 xa1 Data 0 x01 Checksum xc3 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 2 39 Filmmode detection Read Description Reads whether the Filmmode detection is enabled or not Command Command 0 x21 Command 1 xa1 R5976884 RLM SERIES 04 04 2006 77 ...

Страница 80: ...Command 1 x06 Checksum x07 Stop xff Receive awnser Start xfe Projector address x01 Command 0 x21 Command 1 xa1 Data 0 x00 Checksum xc3 Stop xff 2 40 Autoimage execute Description Executes the Autoimage function on the window defined by the first data byte the second byte sets the Autoimage settings If the data bytes are ommited the Autoimage function will be executed on the active window window wh...

Страница 81: ...iption Example executes Autoimage on the window which has the focus the data bytes are ommited Transmit Start xfe Projector address x01 Command 0 xf5 Checksum xf6 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 2 41 Blanking Overview Blanking Reset Blanking enable Write Blanking enable Read Blanking Write Blanking Read Blanking Increme...

Страница 82: ...es the blanking Command Command 0 x20 Command 1 x56 Data Data 0 byTypeBlanking Data 0 0 blanking on image file Data 0 1 blanking on display Data 1 unsigned byte Data 1 0 disable Data 1 1 enable 2 41 3 Blanking enable Read Description Reads whether the blanking is enabled Command Command 0 x21 Command 1 x56 Sent Data byTypeBlanking one byte describing the type of blanking Data 0 0 blanking on image...

Страница 83: ...nd 0 x20 Command 1 x4d Left blanking Command 0 x20 Command 1 x4e Right blanking Command 0 x20 Command 1 x4f Data byTypeBlanking one byte describing the type of blanking Data 0 0 blanking on image file saved in image file Data 0 1 blanking on display Wvalue Unsigned word 2 bytes representing the number of pixels to be blanked Data 1 msb Data 2 lsb The maximum number of pixels which can be blanked d...

Страница 84: ...mand 1 x4c Reads bottom blanking Command 0 x21 Command 1 x4d Reads left blanking Command 0 x21 Command 1 x4e Reads right blanking Command 0 x21 Command 1 x4f Sent Data byTypeBlanking one byte describing the type of blanking Data 0 0 blanking on image file saved in image file Data 0 1 blanking on display 82 R5976884 RLM SERIES 04 04 2006 ...

Страница 85: ...umber of pixels blanked Data 1 msb Data 2 lsb The maximum number of pixels blanked depends on the native resolution of the panels Image 2 2 2 41 6 Blanking Increment Description Increments the blanking value by one Command Increments Top blanking Command 0 x22 Command 1 x4c Increments Bottom blanking Command 0 x22 Command 1 x4d Increments Left blanking Command 0 x22 Command 1 x4e R5976884 RLM SERI...

Страница 86: ...ments Top blanking Command 0 x23 Command 1 x4c Decrements Bottom blanking Command 0 x23 Command 1 x4d Decrements Left blanking Command 0 x23 Command 1 x4e Decrements Right blanking Command 0 x23 Command 1 x4f Data byTypeBlanking one byte describing the type of blanking Data 0 0 blanking on image file saved in image file Data 0 1 blanking on display WStep unsigned word representing the amount of de...

Страница 87: ...rned Data byTypeBlanking one byte describing the type of blanking Data 0 0 blanking on image file saved in image file Data 0 1 blanking on display Unsigned word 2 bytes representing the minimum value to be used for blanking Data 0 msb Data 1 lsb 2 41 9 Maximum Blanking Read Description Reads the Maximum values for the blanking Command Reads minimal top blanking Command 0 x27 Command 1 x4c Reads mi...

Страница 88: ...isplay Returned Data byTypeBlanking one byte describing the type of blanking Data 0 0 blanking on image file saved in image file Data 0 1 blanking on display Unsigned word 2 bytes representing the maximum value to be used for blanking Data 0 msb Data 1 lsb The maximum number of pixels which can be blanked depends on the native resolution of the panels 86 R5976884 RLM SERIES 04 04 2006 ...

Страница 89: ...ol Read Manual Gain Control value Write Manual Gain Control value Read Gain Control Increment Decrement Minimum Maximum AGC value Read Automatic Gain Control interval Write Automatic Gain Control Interval Read Data input format Increment Decrement Data input format write Data input format Read Image files I2C diagnosis Read Panel size Read Logo status Read Take screenshot Logo Save screenshot Logo...

Страница 90: ...nd 1 x0f Returned Data Array containing maximum 20 elements each element containing a C language strings and 5bytes 1 byte for the lamp 1 lamp1 2 lamp2 1 C language string made of 6 bytes for the serial number and 1 STOP byte 4 bytes for the Runtime Data11 Data10 Data9 Data8 Data7 Data6 Data5 Data4 Data3 Data2 Data1 Data0 1st el LAMP SN SN SN SN SN SN STOP RT RT RT RT 20th el LAMP SN SN SN SN SN S...

Страница 91: ...ad PiP Window free size Read Min Max Window horizontal position Write Window horizontal position Read Window vertical position Write Window vertical position Read Window horizontal position Increment decrement PiP Window horizontal position Read Min Max PiP Window vertical position Read Min Max PiP Priority Write Priority Read PiP List active sources Read PiP last added window type Read 3 2 1 PiP ...

Страница 92: ...alue 0 Data A 1 Video A 2 Data B 3 Video B Example Read the PiP window which has the focus result x01 Data A Transmit Start xfe Projector address x01 Command 0 x12 Command 1 x02 Checksum x15 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Awnser Start xfe Projector address x01 Command 0 x12 Command 1 x02 Data 0 x01 90 R5976884 ...

Страница 93: ...deo A 2 Data B 3 Video B Example Gives the focus to a particular PiP window here x01 Data A Transmit Start xfe Projector address x01 Command 0 x12 Command 1 x03 Checksum x16 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 3 2 4 PiP layout Read Description Returns the configuration of a particular layout Command Command 0 x12 Command 1 ...

Страница 94: ...Serial communications Basics Syntax page 9 PiPData binary data describing the PiP layout The data used to write a layout using the write layout command should be of the same form of the data read using the read PIP layout command see PiP layout Read page 91 The data to be send is the data previously read by the PiP layout read command 3 2 6 PiP layout List Read Description Returns the PiP layout l...

Страница 95: ...returns all the layouts Result Full screen 2by2 layout Transmit Start xfe Projector address x01 Command 0 x12 Command 1 x04 Data 0 x2a Data 1 x00 Checksum x41 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Awnser Start xfe Projector address x01 Command 0 x12 Command 1 x04 Data 0 x46 Data 1 x75 Data 2 x6c Data 3 x6c Data 4 x2d ...

Страница 96: ...5 Data 10 x72 Data 11 x00 Checksum x44 Stop xff 3 2 7 PiP current layout Read Description Returns the current PiP layout Command Command 0 x12 Command 1 x05 Returned Data strPipname string The string is of the C language type see chapter 1 Serial communications Basics Syntax page 9 Example Reads the actual PiP layout result Full screen Transmit Start xfe Projector address x01 94 R5976884 RLM SERIE...

Страница 97: ... 1 x06 Checksum x07 Stop xff Receive Awnser Start xfe Projector address x01 Command 0 x12 Command 1 x05 Data 0 x46 Data 1 x75 Data 2 x6c Data 3 x6c Data 4 x2d Data 5 x73 Data 6 x63 Data 7 x72 Data 8 x65 Data 9 x65 Data 10 x6e Data 11 x00 Checksum x58 Stop xff 3 2 8 PiP select layout Write Description Sets a PiP layout R5976884 RLM SERIES 04 04 2006 95 ...

Страница 98: ...the PiP layout Full screen Transmit Start xfe Projector address x01 Command 0 x12 Command 1 x06 Data 0 x46 Data 1 x75 Data 2 x6c Data 3 x6c Data 4 x2d Data 5 x73 Data 6 x63 Data 7 x72 Data 8 x65 Data 9 x65 Data 10 x6e Data 11 x00 Checksum x59 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 96 R5976884 RLM SERIES 04 04 2006 ...

Страница 99: ...ximum 12 characters including the x00 byte The string is of the C language type see chapter 1 Serial communications Basics Syntax page 9 Example Saves the active PiP layout as test Transmit Start xfe Projector address x01 Command 0 x12 Command 1 x08 Data 0 x74 Data 1 x65 Data 2 x73 Data 3 x74 Data 4 x00 Checksum xdb Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command...

Страница 100: ...ng of max 12 characters new layout name The string is of the C language type see chapter 1 Serial communications Basics Syntax page 9 Example Renames the PiP layout test to test2 Transmit Start xfe Projector address x01 Command 0 x12 Command 1 x09 Data 0 x74 Data 1 x65 Data 2 x73 Data 3 x74 Data 4 x00 Data 5 x74 Data 6 x65 Data 7 x73 Data 8 x74 Data 9 x32 Data 10 x00 Checksum xce Stop xff 98 R5976...

Страница 101: ...ameN The strPipnameN string is of the C language type see chapter 1 Serial communications Basics Syntax page 9 Wildcards can be used to specify strPipnameN see Syntax page 9 Example Removes the PiP layout test Transmit Start xfe Projector address x01 Command 0 x12 Command 1 x0a Data 0 x74 Data 1 x65 Data 2 x73 Data 3 x74 Data 4 x00 Checksum xdd Stop xff Receive acknowledge Start xfe Projector addr...

Страница 102: ...eo A 2 Data B 3 Video B Example Removes a particular PiP window here x01 Data A Transmit Start xfe Projector address x01 Command 0 x12 Command 1 x0b Data 0 x01 Checksum x1f Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 3 2 14 Addable sources List read Description This command reads a list of the sources which can be added to the PiP ...

Страница 103: ...indow front background Command Command 0 x12 Command 1 x0c Data Data 0 bySource byte describing the source to be linked to the window Byte value source 1 BNC s 2 D15 3 Composite video 4 SVideo 5 DVI 6 Firewire 7 SDI 8 PC Data 1 byMode byte describing the signals connected to the input section For more info about the input configurations see the projector s Owner s manual for BNC s and D15 Byte val...

Страница 104: ... 1 1024 y 1 768 Note that the panel size projector version can be read using the Panel size command Panel size Read page 159 Xsize and Ysize determine the size of the window since the aspect ratio is fixed one of the values may be sufficient to determine the size of the window If the 2 values do not match the aspect ratio then Xsize is taken as reference and Ysize is calculated to match the aspect...

Страница 105: ...fixed one of the values may be sufficient to determine the size of the window If the 2 values do not match the aspect ratio then Xsize is taken as reference and Ysize is calculated to match the aspect ratio 3 2 17 PiP window size Read Description Returns the size of the active window works in PiP and in Full Screen mode Command Command 0 x21 Command 1 x91 Returned Data Data 0 Data 3 double word Xs...

Страница 106: ...0 x22 Command 1 x91 decrement Command 0 x23 Command 1 x91 Data Data 0 byRepeat optional Note that the panel size projector version can be read using the Panel size command 3 2 19 PiP Window size Read Min Max Description Reads the minimum maximum value for the window size adjustments in PiP Commands read minimum Command 0 x26 Command 1 x91 read maximum Command 0 x27 Command 1 x91 Returned Data Data...

Страница 107: ...it3 is set to 1 the aspect ratio will not be locked free resizing Data 1 Data 4 signed double word XPosition describes the start position of the window x axis Data 5 Data 8 signed double word YPosition describes the start position of the window y axis Data 9 Data 12 signed double word Xsize describes the width of the window x axis Data 13 Data 16 signed double word Ysize describes the height of th...

Страница 108: ...w free size adjustments in PiP Commands read minimum Command 0 x26 Command 1 x92 read maximum Command 0 x27 Command 1 x92 Returned Data Data 1 Data 4 signed double word XPosition describes the min max start position of the window x axis Data 5 Data 8 signed double word YPosition describes the min max start position of the window y axis Data 9 Data 12 signed double word Xsize describes the min max ...

Страница 109: ... 24 Window horizontal position Read Description This command returns the horizontal position of the active window Command Command 0 x21 Command 1 x94 Returned Data Data 0 Data 3 signed double word 3 2 25 Window vertical position Write Description This command sets the vertical position of the active window R5976884 RLM SERIES 04 04 2006 107 ...

Страница 110: ...d Description This command returns the vertical position of the active window Command Command 0 x21 Command 1 x95 Returned Data Data 0 Data 3 signed double word 3 2 27 Window horizontal position Increment decrement Description This command increments decrements the horizontal position of the active window 108 R5976884 RLM SERIES 04 04 2006 ...

Страница 111: ... 2 28 PiP Window horizontal position Read Min Max Description Reads the minimum maximum value for the window horizontal position adjustments in PiP Commands read minimum Command 0 x26 Command 1 x94 read maximum Command 0 x27 Command 1 x94 Returned Data Data 0 Data 3 signed double word Xposition describes the min max width of the window x axis R5976884 RLM SERIES 04 04 2006 109 ...

Страница 112: ...ta 3 signed double word Yposition describes the min max heigth of the window y axis Note that the panel size projector version can be read using the Panel size command 3 2 30 PiP Priority Write Description Sets the priority order of a particular window Command Command 0 x12 Command 1 x0e Command 2 1 2 3 Command 2 1 Top 2 bring to front 3 send to back Data Data 0 Window type byte Window type byte v...

Страница 113: ...tion Reads the priority order of a particular window Command Command 0 x12 Command 1 xoe Command 2 x00 Data Data 0 Window type byte Window type byte value 0 Data A 1 Video A 2 Data B 3 Video B Returned Data Data 0 unsigned byte 0 Top 3 bottom 3 2 32 PiP List active sources Read Description Returns the PiP active sources for each window The returned data is composed of 4 times a determined sequence...

Страница 114: ...r3 4 SDI 0xff None for data windows 0 data 1 SBC oxff None Data 4 source selection word for video windows word value Source 0 video 1 VS 2 R 3 G 4 B 5 Lum 6 Chr 7 Video2 20 PrYPb on RGB 21 RGB video on RGB 22 RGsB video on RGB 100 S video 101 S Video2 102 S Video3 103 S Video4 300 SDI 0xff none for data windows word value source 0 RGBHV 1 RGBCS digital 2 RGBCS analog 6 3 RGSB 100 DssPryPb 6 the si...

Страница 115: ...2 Command 1 x12 Returned Data Data 0 Window type byte 0 Data A 1 Video A 2 Data B 3 Video B 3 3 Viewport Active Write Description Activates or disactivates the viewport function which allow to select an area of the image window in PiP or full screen mode to be visible Image 3 6 Command Command 0 x20 Command 1 xB4 Data Data 0 one byte 0 not active 1 active R5976884 RLM SERIES 04 04 2006 113 ...

Страница 116: ...ort function which allow to select an area of the image window in PiP or full screen mode to be visible Command increment Command 0 x22 Command 1 xB4 decrement Command 0 x23 Command 1 xB4 3 6 Viewport Active Min Max Read Description Returns the Min Max value of the viewport function which allow to select an area of the image window in PiP or full screen mode to be visible Command Minimum Command 0...

Страница 117: ...port relative to the desktop image The value is a percentage of the desktop s width x 10000 Data 3 4 wY word 2 bytes representing the Y start position from the Top of the viewport relative to the desktop image The value is a percentage of the desktop s height x 10000 Data 5 6 wCX word 2 bytes representing the width of the viewport relative to the desktop image The value is a percentage of the desk...

Страница 118: ...of the viewport relative to the desktop image The value is a percentage of the desktop s height x 10000 3 9 Viewport Area Min Max Read Description Returns the minimum maximum values for the viewport area Command minimum Command 0 x26 Command 1 xB5 maximum Command 0 x27 Command 1 xB5 Data Data 0 1 wX word 2 bytes representing the X start position from the Left of the viewport relative to the deskto...

Страница 119: ...yed by each projectors Image 3 9 Desktop setting The positioning of the image is done with the Window position command Command Command 0 xEF Command 1 x81 Data Data 1 Data 4 double word Top describes the Top of the desktop example 1 Data 5 Data 8 double word Left describes the Left of the desktop example 1 Data 9 Data 12 double word Bottom describes the Bottom of the desktop example 768 Data 13 Da...

Страница 120: ...ple 1024 3 12 Digital Zoom Overview Minimum Maximum window size Read Minimum Maximum window X position Read Minimum Maximum window Yposition Read Window size Write Window X position panning Write Window Y position panning Write Window size Read Window X position panning read Window Y position panning read Window size Increment Window X position Increment Window Y position Increment Window size Dec...

Страница 121: ...ription Reads the minimum maximum range zoom window X position Commands read minimum Command 0 x26 Command 1 x82 read maximum Command 0 x27 Command 1 x82 Returned Data Data 0 Data 3 double word 4 bytes min max value Data 4 byte describing the decimal part 2 digits 3 12 3 Minimum Maximum window Yposition Read Description Reads the minimum maximum range zoom window Y position Commands read minimum C...

Страница 122: ...one by sending a percentage 100 corresponds to a zoom window at the right border of the window 0 corresponds to a zoom window at the left border of the window 50 corresponds to a zoom window in the middle of the window Command Command 0 x20 Command 1 x82 Data Data 0 Data 3 double word 4 bytes see chapter 1 Serial communications Basics Data words page 6 corresponding to the desired percentage 100 r...

Страница 123: ...byte represents the decimal part 3 12 8 Window X position panning read Description This command reads the X position of the active window window which has the focus 100 corresponds to a zoom window at the right border of the window 0 corresponds to a zoom window at the left border of the window 50 corresponds to a zoom window in the middle of the window Command Command 0 x21 Command 1 x82 Returned...

Страница 124: ...cified Command Command 0 x22 Command 1 x81 Data Data 0 byRepeat 1 byte to define the rate of increment 3 12 11 Window X position Increment Description This command increments the X position of the zoom window This is done by incrementing the X position percentage the rate of increment can also be specified Command Command 0 x22 Command 1 x82 Data Data 0 byRepeat 1 byte to define the rate of increm...

Страница 125: ... the X position percentage the rate of decrement can also be specified Command Command 0 x23 Command 1 x82 Data Data 0 byRepeat 1 byte to define the rate of decrement 3 12 15 Window Y position Decrement Description This command decrement the Y position of the zoom window This is done by decrementing the Y position percentage the rate of decrement can also be specified Command Command 0 x23 Command...

Страница 126: ...ff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 3 14 Automatic startup Read Description Reads whether the Automatic startup is enabled or not Command Command 0 x21 Command 1 x96 Returned Data Data 0 unsigned byte byte value x00 OFF x01 ON Example Reads the Automatic startup being x00 OFF 124 R5976884 RLM SERIES 04 04 2006 ...

Страница 127: ...0 x00 Command 1 x06 Checksum x07 Stop xff Receive awnser Start xfe Projector address x01 Command 0 x21 Command 1 x96 Data 0 x00 Checksum xb8 Stop xff 3 15 Startup screen Write Description Enables disables the Startup screen Command Command 0 x20 Command 1 x99 Data Data 0 byte type byte value 0 OFF 1 ON Example Enables the Startup screen R5976884 RLM SERIES 04 04 2006 125 ...

Страница 128: ...mand 1 x06 Checksum x07 Stop xff 3 16 Startup screen Read Description Reads whether the Startup screen is enabled or not Command Command 0 x21 Command 1 x99 Returned Data Data 0 unsigned byte byte value x00 OFF x01 ON Example Reads the Automatic startup being x00 OFF Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x99 Checksum xbb Stop xff 126 R5976884 RLM SERIES 04 04 2006 ...

Страница 129: ...nt Input black balance Decrement Input black balance Write Input black balance Read Input white balance Increment Input white balance Decrement Input white balance Write Input white balance Read 3 17 1 Input black balance Increment Description Increments the black input balance for the different color channels Commands Black input balance Red Command 0 x22 Command 1 x84 Black input balance Green C...

Страница 130: ...ommand 0 x23 Command 1 x86 3 17 3 Input black balance Write Description Writes the black input balance for the different color channels to the projector Commands Black input balance Red Command 0 x20 Command 1 x84 Black input balance Green Command 0 x20 Command 1 x85 Black input balance Blue Command 0 x20 Command 1 x86 Data Data 0 lsb Data 1 msb 3 17 4 Input black balance Read Description Reads th...

Страница 131: ...ata 0 lsb Data 1 msb Example Reads the black input balance for Red being x10 Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x84 Checksum xa6 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive Awnser Start xfe Projector address x01 Command 0 x21 Command 1 x84 Data 0 x10 Data 1 x00 R5976884 RLM SERIES 04 04 2006 12...

Страница 132: ...Blue Command 0 x22 Command 1 x89 3 17 6 Input white balance Decrement Description Decrements the white input balance for the different color channels Commands White input balance Red Command 0 x23 Command 1 x87 White input balance Green Command 0 x23 Command 1 x88 White input balance Blue Command 0 x23 Command 1 x89 3 17 7 Input white balance Write Description Writes the white input balance for th...

Страница 133: ...t balance for the different color channels from the projector Commands White input balance Red Command 0 x21 Command 1 x87 White input balance Green Command 0 x21 Command 1 x88 White input balance Blue Command 0 x21 Command 1 x89 Returned Data Data 0 lsb Data 1 msb Example Reads the White input balance for Red being x10 Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x86 Checksum ...

Страница 134: ...ts up the AutoImage i e selects the AutoImage parameters Command Command 0 x20 Command 1 x90 Data Unsigned word see chapter 1 Serial communications Basics Data words page 6 Data 0 unsigned byte msb Data 1 unsigned byte lsb Parameter Data 0 Data 1 Hex Value Total Pixels 0000 0001 x01 Contrast Brightness 0000 0010 x02 Phase 0000 0100 x04 Start pixel line 0000 1000 x08 Total pixels cont bright 0000 0...

Страница 135: ...ads the AutoImage set up Command Command 0 x21 Command 1 x90 Returned Data Unsigned word see chapter 1 Serial communications Basics Data words page 6 Data 0 unsigned byte msb Data 1 unsigned byte lsb Parameter Data 0 Data 1 Hex Value Total Pixels 0000 0001 x01 Contrast Brightness 0000 0010 x02 Phase 0000 0100 x04 Start pixel line 0000 1000 x08 Total pixels cont bright 0000 0011 x03 Example reads t...

Страница 136: ...and 0 x00 Command 1 x06 Checksum x07 Stop xff Receive awnser Start xfe Projector address x01 Command 0 x21 Command 1 x90 Data 0 x00 Data 1 x01 Checksum xb3 Stop xff 3 20 Automatic Gain Control write Description Enables disables the Automatic Gain Control Command Command 0 x20 Command 1 x9b Data Data 0 byte type byte value 0 OFF 1 ON 134 R5976884 RLM SERIES 04 04 2006 ...

Страница 137: ...dress x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 3 21 Automatic Gain Control Read Description Reads whether the AGC is enabled or not Command Command 0 x21 Command 1 x9b Returned Data Data 0 unsigned byte byte value x00 OFF x01 ON Example Reads the AGC setting being x00 OFF Transmit Start xfe Projector address x01 Command 0 x21 Command 1 x9b R5976884 RLM SERIES 04 04 2006 135 ...

Страница 138: ...xfe Projector address x01 Command 0 x21 Command 1 x9b Data 0 x00 Checksum xbd Stop xff 3 22 Manual Gain Control value Write Description Sets the manual gain control value Command Command 0 x20 Command 1 xa2 Data Data 0 lsb Data 1 msb Example Sets the AGC to 10 Transmit Start xfe Projector address x01 Command 0 x20 Command 1 xa2 Data 0 x0a 136 R5976884 RLM SERIES 04 04 2006 ...

Страница 139: ...ontrol value Read Description Reads the actual gain control value Command Command 0 x21 Command 1 xa2 Returned Data Data 0 lsb Data 1 msb Example Reads the AGC value being x0A 10 Transmit Start xfe Projector address x01 Command 0 x21 Command 1 xa2 Checksum xc4 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 R5976884 RLM SERIES 04 04 2006 137 ...

Страница 140: ...Increment Decrement Description Increments decrements the Gain Control value by one Commands increment Command 0 x22 Command 1 xa2 decrement command 0 x23 command 1 xa2 3 25 Minimum Maximum AGC value Read Description Reads the minimum maximum AGC Automatic Gain Control value Commands read minimum Command 0 x26 Command 1 xa2 read maximum Command 0 x27 Command 1 xa2 138 R5976884 RLM SERIES 04 04 200...

Страница 141: ...pe byte value 0 short 1 long Example Sets the AGC interval to short Transmit Start xfe Projector address x01 Command 0 x20 Command 1 x9c Data 0 x00 Checksum xbd Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff 3 27 Automatic Gain Control Interval Read Description Reads the AGC interval short or long R5976884 RLM SERIES 04 04 2006 139 ...

Страница 142: ...ss x01 Command 0 x21 Command 1 x9c Checksum xbe Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff Receive awnser Start xfe Projector address x01 Command 0 x21 Command 1 x9c Data 0 x00 Checksum xbe Stop xff 3 28 Data input format Increment Decrement Description Increments decrements the Data input format setting 140 R5976884 RLM SERIES 04...

Страница 143: ...ta input format Command Command 0 x20 Command 1 xa4 Data Data 0 byte type Data format byte value RGB 0 CrYCb 1 HDTV CrYCb 2 3 30 Data input format Read Description Reads the actual data input format setting Command Command 0 x21 Command 1 xa4 Returned Data Data 0 byte type Data format byte value RGB 0 CrYCb 1 HDTV CrYCb 2 R5976884 RLM SERIES 04 04 2006 141 ...

Страница 144: ...te Clamp position Read Minimum Maximum clamp position Read Comb filter Increment Decrement comb filter Write Comb filter Read Minimum Maximum comb filter Read Horizontal sync polarity Increment Decrement Minimum Maximum Horizontal sync polarity Read Horizontal sync polarity Read Horizontal sync polarity Write Sync locking Increment Decrement Minimum Maximum Horizontal Sync locking Read Sync lockin...

Страница 145: ... another file destination file The source file and the destination file must always be custom files see Syntax page 9 Command Command 0 xc3 Send Data strFilenameFrom strFilenameTo strFilenameFrom and strFilenameTo are strings of the C string type see Syntax page 9 3 31 4 Move File Description This command moves an image file source file to another file destination file When moving a file from a lo...

Страница 146: ...haracterisitics Commands write total lines Command 0 x20 Command 1 x58 write active lines Command 0 x20 Command 1 x59 write line start Command 0 x20 Command 1 x5a write period Command 0 x20 Command 1 x5b write total pixels Command 0 x20 Command 1 x5c write active pixels Command 0 x20 Command 1 x5d write pixel start Command 0 x20 Command 1 x5e write clamp width Command 0 x20 Command 1 x68 144 R5976...

Страница 147: ...clamp width unsigned byte 3 31 6 Image files settings read Description These commands reads the image files characterisitics Commands Read total lines Command 0 x21 Command 1 x58 Read active lines Command 0 x21 Command 1 x59 Read line start Command 0 x21 Command 1 x5a Read period Command 0 x21 Command 1 x5b Read total pixels Command 0 x21 Command 1 x5c Read active pixels Command 0 x21 Command 1 x5...

Страница 148: ...ixel start unsigned word 2 bytes clamp width unsigned byte 3 31 7 Image files settings Increment Description These commands set the image files characterisitics Commands Increment total lines Command 0 x22 Command 1 x58 Increment active lines Command 0 x22 Command 1 x59 Increment line start Command 0 x22 Command 1 x5a Increment period Command 0 x22 Command 1 x5b Increment total pixels Command 0 x2...

Страница 149: ...decrement total lines Command 0 x23 Command 1 x58 decrement active lines Command 0 x23 Command 1 x59 decrement line start Command 0 x23 Command 1 x5a decrement period Command 0 x23 Command 1 x5b decrement total pixels Command 0 x23 Command 1 x5c decrement active pixels Command 0 x23 Command 1 x5d decrement pixel start Command 0 x23 Command 1 x5e decrement clamp width Command 0 x23 Command 1 x68 R5...

Страница 150: ...mand 1 x58 minimum active lines Command 0 x26 Command 1 x59 maximum active lines Command 0 x27 Command 1 x59 minimum line start Command 0 x26 Command 1 x5a maximum line start Command 0 x27 Command 1 x5a Minimum period Command 0 x26 Command 1 x5b maximum period Command 0 x27 Command 1 x5b minimum total pixels Command 0 x26 Command 1 x5c maximum total pixels Command 0 x27 Command 1 x5c minimum activ...

Страница 151: ... x68 3 31 10 VCO Increment VCO The Voltage Controlled Oscillator is used in a Phase Locked Loop which allows to synchronise the data pocessing with the incoming source data Description Increments the VCO by one Command Command 0 x22 Command 1 xa8 3 31 11 VCO decrement VCO The Voltage Controlled Oscillator is used in a Phase Locked Loop which allows to synchronise the data pocessing with the incomi...

Страница 152: ...read max min commands range min Minimum VCO Read page 151 range max Maximum VCO Read page 151 3 31 13 VCO Read Description Reads the actual VCO value of the projector Command Command 0 x21 Command 1 xa8 Returned Data Data 0 VCO value data type unsigned byte Example Reads the actual VCO value the awnser being x00 Transmit Start xfe Projector address x01 Command 0 x21 Command 1 xa8 Checksum xca Stop...

Страница 153: ...iption Reads the minimum range VCO value of the projector Command Command 0 x26 Command 1 xa8 Returned Data Data 0 minimum VCO value 3 31 15 Maximum VCO Read Description Reads the Maximum range VCO value of the projector Command Command 0 x27 Command 1 xa8 Returned Data Data 0 Maximum VCO value 3 31 16 Charge pump current Increment Decrement Description Increments decrements the charge pump curren...

Страница 154: ...ype 3 31 18 charge pump current Read Description Reads the charge pump current Command Command 0 x21 Command 1 x9d Returned Data Data 0 unsigned byte 3 31 19 Minimum Maximum charge pump current Read Description Reads the minimum max charge pump current for the VCO Commands read minimum Command 0 x26 Command 1 x9d read maximum Command 0 x27 Command 1 x9d Returned Data Data 0 minimum VCO value 152 R...

Страница 155: ...on Write Description Sets the clamp position Command Command 0 x20 Command 1 x9e Data Data 0 byte type 3 31 22 Clamp position Read Description Reads the clamp position Command Command 0 x21 Command 1 x9e Returned Data Data 0 unsigned byte 3 31 23 Minimum Maximum clamp position Read Description Reads the minimum max clamp position Commands read minimum Command 0 x26 Command 1 x9e read maximum R5976...

Страница 156: ...ands increment Command 0 x22 Command 1 xa0 decrement command 0 x23 command 1 xa0 3 31 25 comb filter Write Description Enables disables the comb filter Command Command 0 x20 Command 1 xa0 Data Data 0 byte type byte value 0 OFF 1 ON Example Enables the comb filter Transmit Start xfe Projector address x01 Command 0 x20 Command 1 xa0 Data 0 x00 Checksum xc1 Stop xff 154 R5976884 RLM SERIES 04 04 2006...

Страница 157: ...r is enabled or not Command Command 0 x21 Command 1 xa0 Returned Data Data 0 unsigned byte byte value x00 OFF x01 ON Example Reads the comb filter being x00 OFF Transmit Start xfe Projector address x01 Command 0 x21 Command 1 xa0 Checksum xc2 Stop xff Receive acknowledge Start xfe Projector address x01 Command 0 x00 Command 1 x06 Checksum x07 Stop xff R5976884 RLM SERIES 04 04 2006 155 ...

Страница 158: ... 1 xa0 read maximum Command 0 x27 Command 1 xa0 Returned Data Data 0 min max value 3 31 28 Horizontal sync polarity Increment Decrement Description Increments decrements the horizontal sync polarity by one Commands increment Command 0 x22 Command 1 xa9 decrement command 0 x23 command 1 xa9 3 31 29 Minimum Maximum Horizontal sync polarity Read Description Reads the minimum max Horizontal sync polar...

Страница 159: ...e low 1 active high 2 auto determined by ADC 3 31 31 Horizontal sync polarity Write Description Sets the Horizontal sync polarity setting in the image file Command Command 0 x20 Command 1 xa9 Data Data 0 byte 0 active low 1 active high 2 auto determined by ADC 3 31 32 Sync locking Increment Decrement Description Increments decrements the Sync locking setting by one Commands increment Command 0 x22...

Страница 160: ...yte 0 slow 1 fast 3 31 34 Sync locking Read Description Reads the Sync locking setting Command Command 0 x21 Command 1 xab Returned Data Data 0 byte 0 slow 1 fast 3 31 35 Sync locking Write Description Sets the Sync locking fast or slow Command Command 0 x20 Command 1 xab Data Data 0 byte 0 slow 1 fast 3 32 I2C diagnosis Read Description Reads the I2C diagnosis Command Command 0 x81 Command 1 x01 ...

Страница 161: ...ADC 9887 layer2 x9a DVI indicators layer1 x7e DVI indicators layer2 x7a Video decoder x42 Video indicators x7c Table 3 286 address overview Returned Data Data 0 strDiagnosis1 Data 1 strDiagnosis2 Data N 1 strDiagnosisN 3 33 Panel size Read Description Reads the size of the LCD panels Command Command 0 xf0 Command 1 x01 Returned Data Data 0 Data 3 wpixels unsigned word see chapter 1 Serial communic...

Страница 162: ...bit0 saving valid fullscreen active Table 3 289 byStatus byte description 3 35 Take screenshot Logo Description Takes a screenshot of the projected image for the logo the logo image information is stored in an SDRAM Command Command 0 xf1 Command 1 x86 Example Takes a screenshot Transmit Start xfe Projector address x01 Command 0 xf1 Command 1 x86 Checksum x78 Stop xff Receive acknowledge Start xfe ...

Страница 163: ...e take screenshot command Take screenshot Logo page 160 from the SDRAM to a flash memory load logo save logo take screenshot F l a s h m e m o r y S D R A M abort save logo Image 3 11 Command Command 0 xf1 Command 1 x87 3 37 Abort saving screenshot Logo Description Aborts saving the previously taken screenshot R5976884 RLM SERIES 04 04 2006 161 ...

Страница 164: ...e logo take screenshot F l a s h m e m o r y S D R A M abort save logo Image 3 12 Command Command 0 xf1 Command 1 x88 3 38 Load logo Description Loads the logo present in the flash memory in the SDRAM 162 R5976884 RLM SERIES 04 04 2006 ...

Страница 165: ...3 Advanced Commands load logo save logo take screenshot F l a s h m e m o r y S D R A M abort save logo Image 3 13 Command Command 0 xf1 Command 1 x88 R5976884 RLM SERIES 04 04 2006 163 ...

Страница 166: ...3 Advanced Commands 164 R5976884 RLM SERIES 04 04 2006 ...

Страница 167: ...des Key simulation will only work if the function is supported by the firmware RCU Button Command 0 x19 1 x10 2 x11 3 x12 4 x13 5 x14 6 x15 7 x16 8 x17 9 x18 Standby x0e Mute x1f Text x0d Volume x38 Volume x39 Brightness x27 Brightness x2a Brightness x2b Contrast x25 Contrast x28 Contrast x29 Color x30 Color x2c Color x2d Bass x3a Bass x3b R5976884 RLM SERIES 04 04 2006 165 ...

Страница 168: ... x34 Phase x35 Sharpness x36 Sharpness x37 x04 x05 Menu x09 Exit x08 Address x20 x07 x06 Enter x0a Freeze x1b F1 x6b F2 x6c F3 x6d F4 x6e F5 x6f Help x1e Pause x0f Back x08 Auto image x69 PiP select x58 Lens focus up x41 Lens focus down x42 Lens zoom up x43 Lens zoom down x44 Lens shift up x70 166 R5976884 RLM SERIES 04 04 2006 ...

Страница 169: ...4 RCU commands Button Command Lens shift down x71 Digital zoom up x7d Digital zoom down x7e Logo x78 PiP adj x68 Lens adj x77 R5976884 RLM SERIES 04 04 2006 167 ...

Страница 170: ...4 RCU commands 168 R5976884 RLM SERIES 04 04 2006 ...

Страница 171: ... 5 B 8520 Kuurne Phone 32 56 36 89 70 Fax 32 56 36 88 24 E mail service media_and_entertainment emea barco com Web www barco com From Date Please correct the following points in this documentation R5976884 02 page wrong correct R5976884 RLM SERIES 04 04 2006 ...

Отзывы: