Document number: TS RHDM-1701 - K5960056
Issue: 00
Release date: 3 aug 2010
Technical specifications
Page 45 of 52
www.barco.com
8.3.4
EMI/EMC
8.3.4.1
EMI/EMC notice
The unit meets the following specifications when mounted in test console (to
reflect the real application). Internally in the console, a sealed power supply
cable is used to connect the unit to the console connector. Also internally in
the console, the signal cables will be unshielded.
Externally, the power cable will be unshielded and the signal cables shielded.
Network cables (ethernet, tally) should be shielded to meet the specifications.
8.3.4.2
EN norms
•
The unit is targeted to meet following EN specifications:
Reference
Test Description
Performance Level
Compliant
EN 55022
Conducted Emission
A
YES
EN 55022
Radiated Emission
A
YES
EN 61000-3-2
Conducted Emission
Harmonic Currents
According to Class D
YES
EN 61000-3-3
Voltage Changes
Fluctuation
Not applicable
YES
•
EN55024 – Susceptibility specifications
Reference
Test Description
Performance Level
Compliant
EN 61000-4-2 ESD
ESD
4kV contact
8 kV air
Level 3
YES
EN 61000-4-3
Electro Magnetic Field
3 V/m
Level 2
YES
EN 61000-4-4
Burst
0.5 kV Signal ports if
cable > 3m
1 kV on lines & earth
Level 3
YES
EN 61000-4-5
Surges
1.5 kV Signal ports if
outdoor
1 kV line to line
2 kV line to earth
Level 3
YES
EN 61000-4-6
Conducted Common
Mode
3 V
level 2
YES
EN 61000-4-8
Power Frequency
Magnetic Field
Not Applicable
YES
EN 61000-4-11
Voltage Dips
Dip 95% for 0,5 period
YES