background image

7. Additional operations

7. ADDITIONAL OPERATIONS

7.1 Reset Lamp Run time

Resetting the lamp run time

Reset lamp run time is only allowed when a new lamp is installed.

How to reset the lamp run time ?

1. Start up the projector.

2. Enter the adjustment mode by pushing

ENTER

.

3. Push the cursor key

or

to highlight

Service

. (menu 7-1)

4. Press

ENTER

to select

5. Push the cursor key

or

to highlight

Reset Lamp Runtime

. (menu 7-2)

6. Press

ENTER

.

The following warning will be displayed :

Risk of electrical shock. Reset lamp run time is reserved to qualified service personnel. If you are not qualified, press

EXIT

to

cancel the reset operation. (menu 7-3)

7. Enter the serial number of the new lamp with the digit keys on the RCU. Start with 0 and continue with the number previously

written down. see Partslist of the Kit, page 3 (menu 7-4)

8. Press ENTER to continue.

ADJUSTMENT MODE

Select a path from below :

AUTO IMAGE

RANDOM ACCESS

INSTALLATION

SERVICE

Source 01

Select with

or

then <ENTER>

<EXIT> to return

Menu 7-1

SERVICE

IDENTIFICATION

CHANGE PASSWORD
CHANGE LANGUAGE

CHANGE PROJ. ADDRESS

CHANGE BAUDRATE PC

RESET LAMP RUNTIME

LAMP RUNTIME HISTORY

LAMP DIMMING

MORE...

Select with

or

then <ENTER>

<EXIT> to return

Menu 7-2

WARNING

---------------------

RISK OF

ELECTRICAL SHOCK

---------------------

RESET LAMP RUN TIME

is reserved to

qualified

service personnel

<ENTER> to accept

<EXIT> to return

Menu 7-3

RESET LAMP RUNTIME

Enter the serial number

of the new lamp:

xxxxxxx

<ENTER> to accept

<EXIT> to return

Menu 7-4

7.2 Cleaning the dust filters

Necessary tools

a flat screwdriver 5 mm.

How to clean the dust filters ?

1. Turn the projector upside down.

2. Turn out the 2 fixation screws of both dust filters. (image 7-1, image 7-2)

3. Clean the dust filter with a dry cloth.

4. Re-insert the dust filter.

5. Secure their position by insertion and tightening 2 fixation screws.

R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002

15

Содержание R9841550

Страница 1: ...BARCO PROJECTION UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS R9841550 INSTALLATION MANUAL 15032002 R5976452 01...

Страница 2: ...Barco nv Intelligent Displays Noordlaan 5 8520 Kuurne Phone 32 56 36 82 11 Fax 32 56 35 86 51 E mail presentations bid barco com Visit us at the web www barco com Printed in Belgium...

Страница 3: ...t names mentioned in this manual serve as comments or examples and are not to be understood as advertising for the products or their manufactures Copyright All rights reserved No part of this document...

Страница 4: ......

Страница 5: ...uurne Phone 32 56 36 82 11 Fax 32 56 35 86 51 E mail presentations bid barco com Web www barco com From Date Please correct the following points in this documentation R5976452 01 page wrong correct R5...

Страница 6: ......

Страница 7: ...igh pressure which may explode suddenly There is a risk of personal injury and property damage from hot quartz arc tube particles if handled incorrectly Power down the projector and unplug the power c...

Страница 8: ...1 Safety 2 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Страница 9: ...t is designed for the 6500 R G 6400i and SIM6 HB projectors 2 2 Partslist of the Kit Partslist overview Depending on the Kit ordered R9841550 single lamp R98415501 12 pack R98415502 60 pack following...

Страница 10: ...2 Kit content 2 3 Illustration of the Lamp Universal lamp Image 2 1 4 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Страница 11: ...sure that the projector is turned off Never open the lamp house when the projector is on Necessary tools flat screwdriver of 5 mm How to remove the lamp door 1 Turn with a screwdriver the door lock s...

Страница 12: ...image 3 3 2 Pivote the plate a little downwards image 3 4 3 Take out the protection cover Image 3 3 Image 3 4 Hot surface Do not touch the fan blades High pressure lamp may explode if improperly hand...

Страница 13: ...between thumb and finger 4 Unlock the connector by pushing at the same time on both lock parts and separate the connectors image 4 3 Image 4 1 Image 4 2 Image 4 3 The length of the lamp power cables m...

Страница 14: ...4 Removing the old lamp unit 8 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Страница 15: ...ry tools flat screwdriver 5mm Phillips screwdriver 3mm Adjusting the lamp 1 Place the metallic plate as shown on the figures depending on the mounting configuration image 5 1 image 5 2 To place the la...

Страница 16: ...n the housing as shown on the image 2 Connect the connector at the lamp side into the connector at the power side image 5 6 3 Slide the lamp unit in the lamp house until the ref holes in the bottom pa...

Страница 17: ...5 Installing the lamp unit Image 5 7 A reference holes R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002 11...

Страница 18: ...5 Installing the lamp unit 12 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Страница 19: ...he lamp power cable Do not stick this cable between the protection cover and the lamp house 2 Secure the position of the cover with the 3 indicated bolts image 6 2 Image 6 1 Image 6 2 Closing the lamp...

Страница 20: ...6 Closing the lamp house Image 6 3 Image 6 4 14 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Страница 21: ...to continue ADJUSTMENT MODE Select a path from below AUTO IMAGE RANDOM ACCESS INSTALLATION SERVICE Source 01 Select with or then ENTER EXIT to return Menu 7 1 SERVICE IDENTIFICATION CHANGE PASSWORD C...

Страница 22: ...7 Additional operations Image 7 1 Image 7 2 16 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Страница 23: ...ing the dust filters 15 I Installing 9 lamp 9 K Kit 3 4 content 3 Illustration 4 partslist 3 purpose 3 L Lamp 5 9 access 5 installing 9 Lamp run time 15 reset 15 Lamp unit 7 13 closing 13 extracting 7...

Отзывы: