5. Getting Started
ERROR
DMD out of operating
temperature
range
Automatic shutdown is
activated
Menu 5-1
5.4 Quick Set Up Adjustments
Overview
•
•
•
5.4.1
Quick Language Change
What can be done?
Only if different on screen languages are available, these can be changed in quick way by following the next procedure.
How to change
1. Press
ENTER
to start up the adjustment mode.
2. Press the cursor key
↑
or
↓
to highlight
Service
. (menu 5-2)
When password protected, your password will be asked. (more explanation about access by password can be found in Chapter
’Start up the Adjustment mode’.
3. Press
ENTER
to display the Service mode menu.
4. Push the cursor key
↑
or
↓
to highlight
Change Language
. If not visible in the menu, highlight first
More
and press
ENTER
to
display a second service menu. Select then
Change Language
. (menu 5-3)
5. Press
ENTER
to display the
language selection
menu.
6. Push the cursor key
↑
or
↓
to highlight the desired language. (menu 5-4)
Note:
For the moment, only English is available.
ADJUSTMENT MODE
Select a path from below :
RANDOM ACCESS
INSTALLATION
SERVICE
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 5-2
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION
NETWORK
LAMP
DIMMING
MORE...
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 5-3
CHANGE LANGUAGE
ENGLISH
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 5-4
5.4.2
Quick Lens Adjustment
Quick zoom/focus adjustment
1. Press the Selection key
*
, Barco key.
The zoom/focus menu will be displayed. (image 5-3)
2. Push the cursor key
↑
or
↓
to zoom and
←
or
→
to focus the image.
3. When finished, press
EXIT
key to return or
ENTER
to continue to the shift adjustment.
48
R5976801 SLM R9+ 20/10/2004
Содержание R9010310
Страница 1: ...SLM R9 Owner s manual R9010310 R5976801 01 20 10 2004...
Страница 4: ......
Страница 8: ...Table of contents 4 R5976801 SLM R9 20 10 2004...
Страница 14: ...2 Packaging and Dimensions 10 R5976801 SLM R9 20 10 2004...
Страница 20: ...3 Installation Guidelines Air OUT Image 3 6 Safety area around the projector 16 R5976801 SLM R9 20 10 2004...
Страница 33: ...3 Installation Guidelines A B Image 3 27 Opening the rigging sockets R5976801 SLM R9 20 10 2004 29...
Страница 34: ...3 Installation Guidelines 30 R5976801 SLM R9 20 10 2004...
Страница 92: ...7 Random Access Adjustment Mode 88 R5976801 SLM R9 20 10 2004...
Страница 124: ...10 Programmable Function Keys 120 R5976801 SLM R9 20 10 2004...
Страница 128: ...A Standard Source set up Files 124 R5976801 SLM R9 20 10 2004...
Страница 132: ...B Dust filter Replacement 128 R5976801 SLM R9 20 10 2004...