R5906897 /02
Prometheus III
160
Max
Min
1
2
Image 13-8: Cooling liquid check
1
Max level
2
Min level
If the current liquid cooling level is somewhere between
Min
and
Max
, then no action should be taken.
If the current liquid cooling level is approaching the
Min
level point, than check for leakage in the cooling
system prior starting the refill procedure.
If you cannot see the level, open the filler cap and shine a torch into the reservoir
13.9 Cooling liquid refill
WARNING:
This procedure may only be performed by qualified technical service personnel.
Order info cooling liquid
B1909086K : bottle of 1 liter cooling liquid.
Required parts
Cooling liquid
How to refill
1.
Remove the side cover,
“
2.
Open the filler cap by turning it anti clockwise.
Содержание Prometheus III
Страница 1: ...ENABLING BRIGHT OUTCOMES Installation manual Prometheus III...
Страница 8: ...R5906897 02 Prometheus III 8...
Страница 32: ...R5906897 02 Prometheus III 32 Installation process...
Страница 62: ...R5906897 02 Prometheus III 62 Physical installation stand alone cooler...
Страница 80: ...R5906897 02 Prometheus III 80 Lenses lens holder...
Страница 98: ...R5906897 02 Prometheus III 98 Input communication...
Страница 100: ...R5906897 02 Prometheus III 100 Installing a HDD into the ICMP ICMP...
Страница 132: ...R5906897 02 Prometheus III 132 Communicator Touch Panel...
Страница 148: ...R5906897 02 Prometheus III 148 Removal and installation of the projector covers...
Страница 152: ...R5906897 02 Prometheus III 152 Preventative maintenance actions...
Страница 170: ...R5906897 02 Prometheus III 170 Convergence...
Страница 176: ...R5906897 02 Prometheus III 176 Color calibration...
Страница 199: ...R5906897 02 Prometheus III 199 Environmental Information...