manualshive.com logo in svg
background image

Hardware & Software

Installation & User Manual

MGP 15 Dicom Theater

Содержание MGP 15 Dicom Theater

Страница 1: ...Hardware Software Installation User Manual MGP 15 Dicom Theater...

Страница 2: ...y are distributed under copyright by Barco N V or BarcoView LLC for use only under the specific terms of a software license agreement between Barco N V or BarcoView LLC and the licensee No other use d...

Страница 3: ...ial area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Disposal Information The lamps inside the display contain mercur...

Страница 4: ...4 MGP 15 Dicom Theater This page intentionally left blank...

Страница 5: ...ual head with two displays and two projectors 19 e Dual head with two displays and one projector picture in picture 21 Display Controller Installation 23 BarcoMed 2MP2CP Overview 25 Minimum system req...

Страница 6: ...BarcoMFD library 47 Display Properties 48 BarcoMed Driver Tab 51 Introduction 51 Languages supported 51 Using the BarcoMed Driver Tab 51 Status 52 Graphics Board 52 Driver Version 52 Resolution 53 Mon...

Страница 7: ...Saver 68 Using the Barco DPMS Screen Saver 69 Installing or Reinstalling Barco DPMS 72 Uninstalling Barco DPMS 73 MediCal Pro and Dicom Theater software 75 MediCal Pro installation 77 Using MediCal P...

Страница 8: ...ng projector properties 89 Troubleshooting the stabilization process 91 Troubleshooting 93 Windows 2000 display resolution 95 Setting the resolution of your Dicom Theater display 95 Driver re installa...

Страница 9: ...9 Introduction...

Страница 10: ...Introduction 10 This page intentionally left blank...

Страница 11: ...system combines ClearBase and BlueBase modes has a user friendly remote control and features versatile connectivity to add a multitude of both color and grayscale application sources including PACS X...

Страница 12: ...id of the external optical sensor this piece of software ensures the stabilization of the projector In addition you can use the Dicom Theater software to control some of the projector s functions Othe...

Страница 13: ...Introduction 13 Minimum system requirements Windows 2000 SP4 or Windows XP SP1 Pentium IV microprocessor At least 1 free USB and COM port per projector A free PCI slot per installed BarcoMed board...

Страница 14: ...he MediCal Pro and DICOM Theater software For more information please refer to the section about the MediCal and Dicom Theater software installation and usage 5 Start and use MediCal Pro For more info...

Страница 15: ...ollows 1 Connect one PC video output to the projector BNC input by means of the DVI to 5 BNC cable 15 m 50 ft 2 Connect the other PC video output to the display DVI video input by means of the DVI cab...

Страница 16: ...usage b Single head with two projectors Figure 2 Proceed as follows 1 Connect one PC video output to the first projector BNC input by means of the DVI to 5 BNC cable 15 m 50 ft 2 Connect the other vid...

Страница 17: ...onnector If the cable is not long enough you have to use a USB booster extender Installation of the sensor is described more in detail in the section MediCal and Dicom Theater software installation an...

Страница 18: ...to D Sub9 cable 15 m 50 ft 4 Connect the I Guard optical sensor to a free PC USB downstream connector If the cable is not long enough you have to use a USB booster extender Installation of the sensor...

Страница 19: ...tion 19 d Dual head with two displays and two projectors Figure 4 BARCO RS 232 USB VIDEO2 RS 232 BARCO VIDEO1 RS 232 VIDEO3 VIDEO4 RS 232 USB Video1 USB Video2 RS 232 Video3 Video4 Video1 Video2 Video...

Страница 20: ...DVI video input of the second display by means of the DVI cable Video 4 in the illustration above 5 Connect a free PC COM port to the RS 232 connector of the first projector by means of the D Sub9 to...

Страница 21: ...picture in picture Figure 5 Proceed as follows 1 Connect one PC video output of the first display controller to the DVI video input of the first display by means of the DVI cable Video 1 in the illus...

Страница 22: ...means of the DVI to VGA cable 15 m 50 ft Video 4 in the illustration above 5 Connect a free PC COM port to the RS 232 connector of the projector by means of the D Sub9 to D Sub9 cable 15 m 50 ft 6 Con...

Страница 23: ...23 Display Controller Installation...

Страница 24: ...Display Controller Installation 24 This page intentionally left blank...

Страница 25: ...quirements 32 bit PCI slot with no obstructions Windows 2000 Service Pack 4 or Windows XP Service Pack 1 Features of the BarcoMed 2MP2CP display controller 32 bit 33MHz Single Slot PCI card 64MB Video...

Страница 26: ...the operating system is booted in VGA mode 640x480 Default Refresh Rate 16 colors The following resolutions are available on each head of the BarcoMed 2MP2CP display controller Native projector resol...

Страница 27: ...BarcoMed 2MP2CP Overview 27 1920x1200 24 bit true color...

Страница 28: ...P display controller s in your PC please take a few minutes to familiarize yourself with both the display controller s and the PCI slots in your computer Figure 6 The BarcoMed 2MP2CP display controlle...

Страница 29: ...MP2CP are enabled Caution To use multiple BarcoMed 2MP2CP controllers in a single host with VGA enabled you should enable VGA on only ONE of the BarcoMed 2MP2CP display controllers and disable VGA on...

Страница 30: ...If you have decided to use the on board VGA capabilities of the BarcoMed 2MP2CP controller see Using the VGA capabilities of the BarcoMed 2MP2CP display controller on page 28 you must now remove any...

Страница 31: ...econnect the power cord turn on the power and boot the system as usual Running multiple BarcoMed 2MP2CP Display Controllers in a single host The physical order of the displays may vary when you are ru...

Страница 32: ...Display controller installation 32 This page intentionally left blank...

Страница 33: ...33 Display Controller Software Installation...

Страница 34: ...Display Controller Software Installation 34 This page intentionally left blank...

Страница 35: ...ure 4 Decide if you are going to install the BarcoMed 2MP2CP driver with Cloned Heads active mode enabled or disabled DualView When Cloned Heads is selected the second head is identical to the first h...

Страница 36: ...ert your Dicom Theater Software CD into your computer s CD drive If the BarcoMed Product Installation Wizard doesn t start within one minute browse the contents of your Dicom Theater Software CD and d...

Страница 37: ...New Hardware Wizard for each BarcoMed 2MP2CP it finds in your system Click Cancel Continue to click Cancel until Windows stops launching the Found New Hardware Wizard Video Controller Again please be...

Страница 38: ...river on your BarcoMed Software CD Select the device you want to install and then click Next Note If there are no BarcoMed devices installed or if Windows does not recognize the installed devices or i...

Страница 39: ...puter you will need to rerun the installer to install the drivers for the other devices If you select a device with an installed driver the wizard will warn you if the installed driver is newer than t...

Страница 40: ...cannot cancel the driver installation Prior to beginning the installation the BarcoMed Driver Install Wizard will warn you that while the driver is being installed your display may flicker Click OK t...

Страница 41: ...driver to install with Cloned Heads mode enabled or disabled then click Next Figure 17 When the Driver Install Wizard tells you that it has successfully installed the selected driver click Finish The...

Страница 42: ...to the BarcoMed Product Install Wizard The wizard will now begin installing the next selected piece of BarcoMed Software Click Cancel then click Yes then click Finish Now Back and try reinstalling the...

Страница 43: ...arning Figure 19 Windows XP Windows Logo Testing Warning The Barco Monitor Plug and Play software should automatically set the resolution for the Barco LCD displays of your Dicom Theater System Howeve...

Страница 44: ...sktop to these displays using the Windows Display Control Panel If for some reason Windows failed to correctly set the resolution of your MGP 15 or displays please turn to the section Setting the reso...

Страница 45: ...45 Display Controller Tools...

Страница 46: ...Display Controller Tools 46 This page intentionally left blank...

Страница 47: ...y those ports with a display attached to them are active If an icon is grayed out that indicates a port with no head attached to it When running DualView under Windows 2000 and Windows XP the desktop...

Страница 48: ...of for 17000 hours after which time it will become slowly dimmer For displays calibrated at an estimate of how long it will be before a backlight replacement is needed 17000 hours backlight age Firmwa...

Страница 49: ...Barco Display Tab 49 Figure 20...

Страница 50: ...Barco Display Tab CORONIS 3MP This page intentionally left blank 50...

Страница 51: ...erman Korean Japanese Simplified Chinese Traditional Chinese To change between the languages select the correct region via the Regional Settings Control Panel in your machine s Start Settings Control...

Страница 52: ...XP Status The Status section displays information about the current BarcoMed display controller driver and the currently selected display resolution Graphics Board This displays the current BarcoMed...

Страница 53: ...which you are working For the BarcoMed 2MP2CP the Monitor Configuration pull down menu allows you to select DualView operation or Cloned Heads operation When DualView is selected each head is complete...

Страница 54: ...BarcoMed Driver Tab CORONIS 3MP This page intentionally left blank 54...

Страница 55: ...he Firmware installed on the board Table 1 AURA Controllers Non AURA Controllers BarcoMed Hardware Tab Support BarcoMed Nio PCI and Firmware Information BarcoMed Coronis PCI and Firmware Information B...

Страница 56: ...you are working with to bring up its properties page Click on the BarcoMed Hardware Tab see figure 22 on page 57 BarcoMed 3MP2FH PCI and Firmware Information BarcoMed 5MP1H PCI Information Only BarcoM...

Страница 57: ...ndows 2000 or Windows XP Device Displays the current BarcoMed display controller driver and the currently selected display resolution Information Device ID Displays the device s PCI Device ID number V...

Страница 58: ...controller installed in the selected PCI slot Hardware Version Displays the Hardware Version for the BarcoMed display controller installed in the selected PCI slot Advanced Button By clicking on this...

Страница 59: ...must be filled in This screen asks the user for contact information that will help the Barco support team contact the customer The user will not be allowed to move forward to the next screen unless a...

Страница 60: ...nly after all of the information is gathered Once the information is gathered the user may not go back in the wizard screens Completion Screen The BarcoMed Self Exam has collected all of the informati...

Страница 61: ...for your country and click on the email link 5 Enter a subject and a brief message describing the problem about which you are requesting help 6 Attach the BarcoMed Self Exam report s to the email mess...

Страница 62: ...BarcoMed Hardware Tab 62...

Страница 63: ...63 Display Tools...

Страница 64: ...Display Tools 64 This page intentionally left blank...

Страница 65: ...y the user can specify that the display first go through two other DPMS Screen Saver states before going into Off state These two other states for the Screen Saver are Stand By and Suspend The user ca...

Страница 66: ...rk Day times as the same time Begin Work Day The Begin Work Day time is the time after which the system is expected to start being used During the work day the screen saver selected by the user in the...

Страница 67: ...y or Suspend states If the user wishes to go into the Stand By or Suspend states before going into the Off state select the required amount of time for each state If requested the display will first g...

Страница 68: ...users of the system However they can be modified only by users with administrator privileges If a user who does not have administrator privileges tries to save a scheme using an existing default sche...

Страница 69: ...n Saver so that Windows will store the selection in the user s profile If a user does not select the Barco DPMS Screen Saver as his screen saver the next time he logs on to the system the screen saver...

Страница 70: ...MS Screen Saver 70 Figure 24 Windows XP Screen Saver Tab 2 Click on the Settings button The Barco DPMS Screen Saver Control Panel will open see figure 25 on page 70 Figure 25 Barco DPMS Settings Contr...

Страница 71: ...es the program will ask you if you wish to save the scheme as a DEFAULT scheme figure 26 on page 71 Click Yes to save the settings scheme as a DEFAULT scheme click No to save the scheme as a PRIVATE s...

Страница 72: ...arco display select the amount of time it takes your display to warm up via the Monitor Setting section Contact your display vendor for this warm up time On Barco CORONIS displays the I GUARD will sta...

Страница 73: ...Saver from your system insert the Dicom Theater Software CD in the appropriate device on your computer run the BarcoMed Product Install Wizard and follow these steps 1 Select only the DPMS Screen Sav...

Страница 74: ...Barco DPMS Screen Saver 74 This page intentionally left blank...

Страница 75: ...75 MediCal Pro and Dicom Theater software...

Страница 76: ...MediCal Pro and Dicom Theater software 76 This page intentionally left blank...

Страница 77: ...structions from the MediCal Pro User Guide Important Do not forget you have to have Administrator privileges to install or uninstall MediCal During installation you will have to indicate you are using...

Страница 78: ...he configuration by using the Configuration Setup wizard 4 For each projector added to the configuration MediCal Pro displays a dialog with which you can adjust the position and size of the patch for...

Страница 79: ...all the devices in the configuration define if necessary and select a Preset 9 After selecting the Preset MediCal Pro starts consistency calibration automatically Please refer to the MediCal Pro User...

Страница 80: ...sor 1 Before attaching the sensor be sure to set the sensor patch to the desired location see above You can always change the position of the patch by means of MediCal Pro 2 Peel off the protective sh...

Страница 81: ...connection 81 Sensor position and screen resolution a Selected resolution of 1280 x 1024 1024 x 1280 Figure 29 b Selected resolution of 1600 x 1200 1200 x 1600 Figure 30 active image 1280x1024 active...

Страница 82: ...atus The icons The application is a sys tray application which means an icon appears in the system bar of Windows indicating the presence of this application Figure 31 The icon in the sys tray indicat...

Страница 83: ...ctivate the preset of her or his choice This will re activate the stabilization process E g in case the user switches inputs or presets by means of the projector s remote control unit stabilization wi...

Страница 84: ...To restart the projector stabilization proceed as follows 1 Position the cursor over the Dicom Theater sys tray icon and click the right mouse button right click The Dicom Theater menu appears Figure...

Страница 85: ...different projectors in the configuration Each projector is represented by a tab So whenever a command is executed the projector that is represented by the current tab is addressed The last tab in the...

Страница 86: ...ure in picture layout in the Picture in Picture section For more information about picture in picture layouts please refer to the MGP 15 Owner s Manual Projector on off status selection To switch the...

Страница 87: ...ctors according to his her best understanding To modify the projector control configuration proceed as follows 1 Position the cursor over the Dicom Theater sys tray icon and click the right mouse butt...

Страница 88: ...ector 88 4 Change the names of the items appearing in the Projector Control view according to your own preferences The changed names are used in the Dicom Theater application only not in the projector...

Страница 89: ...r the Dicom Theater sys tray icon and click the right mouse button right click The Dicom Theater menu appears 2 Click Properties The projector Properties view appears Each projector is represented by...

Страница 90: ...address Lamp Runtime The number of hours the projector lamp has been operating Projector Runtime The number of hours the projector has been operating Input Source The currently selected input source V...

Страница 91: ...sensor is not or no longer positioned on the sensor patch The user has selected another signal input or another preset for the projector In all of these cases you must restore any problems in the con...

Страница 92: ...Troubleshooting the stabilization process 92 This page intentionally left blank...

Страница 93: ...93 Troubleshooting...

Страница 94: ...Troubleshooting 94 This page intentionally left blank...

Страница 95: ...he first display may be set to a VGA resolution of 640 x 480 pixels with 16 colors and a default refresh rate If your BarcoMed 2MP2CP controller is not running VGA the display may not be enabled yet T...

Страница 96: ...of the Display Properties Control Panel Attach the display by right clicking on the rectangle that represents it and selecting Attached Now repeat steps above for this display Figure 36 The Windows Di...

Страница 97: ...stall or update only the BarcoMed 2MP2CP driver follow the steps described in the section Using the BarcoMed Product Installation Wizard with the following changes 1 Boot your system and log in using...

Страница 98: ...to finish reinstalling or updating your BarcoMed 2MP2CP driver When the driver has finished installing click Finish Then click Finish again Reboot the system when prompted and then reset the resolutio...

Страница 99: ...ur Dicom Theater Software CD and double click on the file Setup exe to start the wizard 2 The BarcoMed Product Installation Wizard will display its welcome screen 3 Make certain that the checkbox next...

Страница 100: ...rocess Click Finish again to exit the wizard Click Yes if Windows tells you that you must restart your computer before the new setting will take effect 8 If you have installed your driver in DualView...

Страница 101: ...nish uninstalling the driver by clicking Next three times Then click Reboot Finish and Yes If the BarcoMed Product Installation Wizard doesn t automatically restart finish uninstalling the driver by r...

Страница 102: ...www barco com B4100441 03 August 2004...