4. Facility and system requirements
4. FACILITY AND SYSTEM REQUIREMENTS
About this chapter
This chapter provides information about the installation requirements such as temperature, humidity, power net, safety area around
the device. Also the air intake and air outlet area guidelines are listed.
Overview
•
•
4.1
Environmental requirements
Ambient temperature conditions
Max. ambient temperature : +40°C or 104°F
Min. ambient temperature : +10°C or 50°F
Storage temperature: -35°C to +65°C (–31°F to 149°F)
Humidity Conditions
Storage: 0 to 98% relative humidity, non-condensing
Operation: 0 to 95% relative humidity, non-condensing
Environment
Do not install the device in a site near heat sources such as radiators or air ducts, or in a place subject to direct sunlight, excessive
dust or humidity. Be aware that room heat rises to the ceiling; check that temperature near the installation site is not excessive.
Environment condition check
The device must always be mounted in a manner which ensures the free
fl
ow of clean air into the air intake and out of the air outlet.
4.2
Installation requirements
Rack mount
The device is 19” rack mount, 5U.
In this case the rack mount plate, which delivered with the device, must be installed.
Air
fl
ow guidelines
The air intake is at the front side of the device and the air exhaust is at the back side. It is necessary to keep these areas unblocked.
A free area of at least 40 cm should be available at the front side of the device. A free area of at least 5 cm should be available at
the back of the device.
R5909057 MCM-50 17/05/2016
17
Содержание MCM-50
Страница 1: ...MCM 50 User Guide Optimized for F50 R5909057 02 17 05 2016...
Страница 8: ...Table of contents 4 R5909057 MCM 50 17 05 2016...
Страница 14: ...1 Safety instructions 10 R5909057 MCM 50 17 05 2016...
Страница 20: ...3 Packaging 16 R5909057 MCM 50 17 05 2016...
Страница 22: ...4 Facility and system requirements Image 4 1 18 R5909057 MCM 50 17 05 2016...
Страница 28: ...5 Physical installation and connections 24 R5909057 MCM 50 17 05 2016...
Страница 40: ...6 Setup and configuration Image 6 17 36 R5909057 MCM 50 17 05 2016...
Страница 58: ...8 OSD Preferences 54 R5909057 MCM 50 17 05 2016...
Страница 103: ...11 Expert operation Image 11 45 Image 11 46 Image 11 47 Image 11 48 R5909057 MCM 50 17 05 2016 99...
Страница 118: ...11 Expert operation 114 R5909057 MCM 50 17 05 2016...
Страница 136: ...13 MCM 50 Tools 132 R5909057 MCM 50 17 05 2016...
Страница 144: ...15 RCU Control 140 R5909057 MCM 50 17 05 2016...