6. Control Unit
Command
Parameters
Return Value
Description
sample-
player/get_max_num_chan-
nels
<integer>
Returns maximum al- lowed
number of simulta- neous
playing channels
sampleplayer/load_sample
<integer> slot id
0, <string> path to
sample file
Loads a sample from a
fi
le
into the given slot. The path
is relative to the base path
con
fi
gured in the sampleplayer
plugin. An existing sample in
the slot will be removed
sampleplayer/play_slot
<integer> slot id
0..
Starts playing back a given slot
sampleplayer/stop_slot
<integer> slot id
0..
Stops playing back a given slot
sampleplayer/set_loop
<integer> slot id
0..
Sets the loop state for a given
slot. 0 means off, any other
value means on
sample-
player/get_slot_states
<string> list
, comma
seperated
Returns list of numbers,
representing current slot state.
0-stopped, 1- playing
sampleplayer/get_num_chan-
nels
<integer> slot id
0..
<integer>
Returns list of numbers,
representing current slot state.
0-stopped, 1- playing
6.3.2.2
Command Parameter
About
All available command parameter are described below. Please replace the command parameter wildcards by values described.
<parameter>
Description
<string>
ASCII code that is a name
<string-list>
List of names, each name on a separate line
<integer>
ASCII code that is an integer
<float>
ASCII code that is a
fl
oating-point number
6.3.2.3
Command Execution Status Return
About
All remote control commands lead to an acknowledge status message, indicating the acceptance of the remote control command.
Refer to the description below.
Execution status
Description
:OK:
Command executed succesfully
:EXECUTION_ERROR:
Error during execution of command
:MALFORMED_COMMAND:
Invalid command
:MALFORMED_PARAMETER:
Invalid parameter
6.3.2.4
System Status Messages
About
The following messages are returned after sending remote command "controlunit/get_state".
Status
Description
:STATE_ERROR:
System Error
:STATE_WARNING:
Warning
:STATE_OK:
Status OK
30
R5906746 IOSONO CORE 08/05/2017
Содержание Iosono Core R9801500
Страница 1: ...IOSONO CORE Installation And User Manual R9801500 R9801502 R9801503 R9801504 R5906746 00 08 05 2017 ...
Страница 4: ......
Страница 6: ...1 Introduction 2 R5906746 IOSONO CORE 08 05 2017 ...
Страница 14: ...4 System Startup 10 R5906746 IOSONO CORE 08 05 2017 ...
Страница 24: ...5 Initial System Configuration 20 R5906746 IOSONO CORE 08 05 2017 ...
Страница 52: ...7 Step By Step Configuration 48 R5906746 IOSONO CORE 08 05 2017 ...
Страница 60: ...8 Advanced System Tuning With The System Tuning Extension 56 R5906746 IOSONO CORE 08 05 2017 ...