background image

26-0904001-00 Rev 00.00                                                      

     15

 

 

STMGR 

Description: Logo Management Settings 

 

Parameters:   

--deleteall      : Delete logo 
--eraseall       : Erase logo (destructive) 
--captureall 

 : Capture logo 

--infoall 

 : Logo H/V information        

 

Query Format: n/a 

 
 
 

OCON 

Description: Output Connector Settings 

 

Required parameters:         

--ocon (output connector)      , for output connectors         

    

Parameters:          

--ocon (output connector)    : 0-6, see below for connector numbers. 
--ch (channel select)           : 0-1 
--syncpol (sync polarity)      : 0=+H+V, 1=+H-V, 2=-H+V, 3=-H-V 
--bitdepth (color bit depth)  : 0-6bit, 1-8bit, 2-10bit, 3-12bit 
--csp (color space)              : 0-RGB, 1-SMPTE 

 

Query Format: OCON --ocon (connector) [--qall|--qsettings|--qstatus] 

 

Query Response: 

Output Connector Settings in XML format 

 

Output Connectors:    

0=DVI    
1=HD15 
2=HDMI 
3=DP 
4=SDI1 
5=SDI2 (available when Dual option mezzanine installed) 
6=BNC Composite 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание ImagePRO-II

Страница 1: ...ImagePRO II Dual Output User s Guide Addendum Manual 26 0904001 00 Revision 00...

Страница 2: ...ble for correcting any interference Guarantee and Compensation Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee On receipt the purchase...

Страница 3: ...ks registered trademarks or copyrights of their respective holders All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for th...

Страница 4: ...e ground connection by way of grounding conductor in the power cord is essential for safe operation Grounding the Product This product is grounded through the grounding conductor of the power cord To...

Страница 5: ...26 0904001 00 Rev 00 00 5 Change History The table below lists the changes to the User s Guide Addendum Rev Date ECP Description Approved By 00 6 22 12 597847 Initial Release R Pellicano...

Страница 6: ...tput Connector Map 8 3 Output Configuration 9 Output Resolution 9 Area of Interest 9 Output Timing Adjustment 9 Output Effects 10 Genlock 10 Save and Reset Output Configs 11 Pan Zoom 11 Logo Backup an...

Страница 7: ...erest Effects or even Pan Zoom settings giving the operator maximum flexibility for a given show configuration 1 Getting Started To get started make sure you have an ImagePRO II Dual Output unit R9004...

Страница 8: ...menu scroll to and select the OUTPUT CONNECTOR MAP submenu 2 By default all seven outputs of the ImagePRO II will be mapped to Output A 3 Scroll to the various connectors as required and change the fi...

Страница 9: ...ms to change the output resolution frame rate to the desired choice Area of Interest 1 Select the AREA OF INTEREST submenu under OUTPUT 2 The first field labelled CHANNEL allows the selection of A or...

Страница 10: ...N 3 The second field in the menu CHB SOURCE will default to LOCK TO A With this option Channel B will stay locked to Channel A at all times regardless of the Genlock source selected for Channel A If d...

Страница 11: ...ZOOM button on the front panel of the ImagePRO II 2 The first field labelled CHANNEL allows the selection of A or B to allow independent Pan and Zoom adjustments for each output channel 3 The same ope...

Страница 12: ...g Dual2K mode b All output connectors are assigned to Channel A c A Logo saved in Single mode will be available for both Channel A and Channel B d Channel B Genlock will default to Lock to A 4 When in...

Страница 13: ...Size pixels mask option to set the mask window left Mask Left in percentage right Mask Right in percentage top Mask Top in percentage bottom Mask Bottom in percentage at aspect ratio type 0 6 see bel...

Страница 14: ...when Dual option mezzanine installed Aspect Ratio type 0 1 1 1 3 2 2 4 3 3 5 4 4 16 10 5 16 9 6 Custom Use ar to specify actual aspect ratio IMGR Description Input Manager Settings Parameters acq acqu...

Страница 15: ...nnector for output connectors Parameters ocon output connector 0 6 see below for connector numbers ch channel select 0 1 syncpol sync polarity 0 H V 1 H V 2 H V 3 H V bitdepth color bit depth 0 6bit 1...

Страница 16: ...de Operation Mode conmode Encore Connect Mode unitid Encore Unit ID encoreip Encore IP Address UINPUT Description Input Settings Required parameters con connector itype input type for commands to DVI...

Страница 17: ...ng based from format table name format name This command option simply renames the current format hsync horizontal sync hact horizontal active hfp horizontal front porch hpos horizontal position htot...

Страница 18: ...following format VIDCOL brt ovr bright cbrt R bright G bright b bright cnt ovr contr ccnt R contr G contr B contr sat saturation hue hue cinv invert csp colorspace gamma gamma mono monochrome Query F...

Страница 19: ...values VIEW con connector ch channel pixel Query Response 1 View Settings in the following format VIEW hpos h pos vpos v pos hsize h size vsize v size Connectors 0 DVI 1 D15 2 HDMI 3 DP 4 SDI1 5 SDI2...