6. Optical spares and servicing procedures
Reverse this procedure to mount a lamp.
C
AUTION
:
Do not touch the glass part of the lamp.
6.3
The UV/IR filter
Introduction
The UV/IR filter consists of a glass plate with a UV coating on one side and a IR coating on the other side. The side with UV coating
is marked with a black dot in the corner.
How to remove the UV/IR filter?
1. Remove the lamp — See "The UHP lamp", page 67
2. Loosen (not remove) the two screws
Image 6-9
Two screws holding the UV/IR filter
3. Gently remove the filter
Caution:
Do not touch the glass surface as this will damage the filter.
How to mount the UV/IR filter?
1. Put in the new filter with the UV coating facing the lamp
R59770097 ID H250 / H500 15/05/2007
69
Содержание iD H250
Страница 1: ...iD H250 H500 Service manual R9010570 R9010520 R59770097 00 15 05 2007...
Страница 10: ...1 Safety 6 R59770097 ID H250 H500 15 05 2007...
Страница 22: ...2 General information 18 R59770097 ID H250 H500 15 05 2007...
Страница 24: ...3 Software 20 R59770097 ID H250 H500 15 05 2007...
Страница 68: ...5 Electronic spares and servicing procedures 64 R59770097 ID H250 H500 15 05 2007...
Страница 84: ...6 Optical spares and servicing procedures 80 R59770097 ID H250 H500 15 05 2007...