6. Optical spares and servicing procedures
8
3
5
6
4
Image 6-3
6.2
The UHP lamp
W
ARNING
:
Risk of burns: wait for the projector and lamp to cool down before changing a lamp!
W
ARNING
:
Risk of explosion: changing a lamp can only be done by a Barco authorized technician.
W
ARNING
:
Risk of electrical shock: unplug the mains power cord before removing the covers.
Necessary tools
No tools.
Resetlamp runtime
Only for Barco authorized technicians!
The lamp runtime may only be reset when placing a new lamp.
1. Press
MENU
to activate the tool bar.
2. Press
→
to select the
Lamp
menu
3. Use
↓
to pull down the
Lamp
menu
4. Use
↑
or
↓
to select
Reset runtime
5. Press
→
to pull down the menu
6.
Use
↑
or
↓
to select the lamp to be reset
Image 6-4
7. Press
ENTER
: a dialog box is displayed
Image 6-5
R59770097 ID H250 / H500 15/05/2007