5. Input and Communication
5.6
ICMP reset
This procedure requires that ICMP version 1.2.4 or later is installed.
ICMP reset possibilities
•
The Star button on the local keypad (Not for C- and B-series)
•
The ICMP reset button in the GUI of the Communicator.
•
The ICMP reset button in the GUI of the Commander.
•
The ICMP reset button in the GUI of the Web Commander.
•
The ICMP hardware reset button located on the front panel of the ICMP (Not recommended, use only when all other reset
possibilities are exhausted!)
How to reset the ICMP?
1. Click on the ICMP
reset button
in the GUI of the
Web Commander
Or,
Click on the ICMP
reset button
in the GUI of the
Commander
Note:
It can be that the Commander or WEB-Commander is not able to send the reset command.
Or,
click on the ICMP
reset button
in the GUI of the
Communicator
(recommended)
Or,
press the
Star button
on the
local keypad
for a few seconds (Not for C- and B-series)
As a result the projector is safely prepared for the ICMP reboot. All ongoing events on the ICMP (e.g. ingest) are requested to
end. After a few seconds the ICMP is requested to restart. The READY LED on the front panel of the ICMP starts to blink orange.
In case the ICMP is installed in DP4K-L series projector the lasers are switched off and the projector remains in the same mode
(e.g. Conditioned). The Star button on the local keypad starts blinking green. After the reset of the ICMP the lasers are switched
on again.
Once the READY LED lit continuous green the ICMP is up and running.
2. Did the reset of the ICMP fail?
If yes, perform a hardware reset as follows:
a) switch off the lasers of the projector or switch of the projector lamp.
b) press the ICMP
hardware reset button
a few seconds (reference 3 image 5-6) .
Warning:
Resetting the ICMP with the hardware reset button may cause damage to the content on the HDDs. A re-con
fi
gu-
ration of the whole system may be required!
As a result the projector is safely prepared for the ICMP reboot. All ongoing events on the ICMP (e.g. ingest) are stopped
immediately and the ICMP restarts.
3
Image 5-6
W
ARNING
:
Resetting the ICMP with the hardware reset button may cause damage to the content on the HDDs.
A re-con
fi
guration of the whole system may be required!
64
R5905823 HDQ 4K35 30/11/2015
Содержание HDQ 4K35
Страница 1: ...HDQ 4K35 User and Installation manual R5905823 04 30 11 2015 ...
Страница 4: ......
Страница 43: ...4 Lenses Lens Holder Image 4 7 R9856294 Image 4 8 R9856297 Image 4 9 R9856300 R5905823 HDQ 4K35 30 11 2015 39 ...
Страница 58: ...4 Lenses Lens Holder 54 R5905823 HDQ 4K35 30 11 2015 ...
Страница 69: ...6 Starting up 6 STARTING UP R5905823 HDQ 4K35 30 11 2015 65 ...
Страница 70: ...6 Starting up 66 R5905823 HDQ 4K35 30 11 2015 ...
Страница 84: ...7 Maintenance 80 R5905823 HDQ 4K35 30 11 2015 ...
Страница 96: ...8 Removal and installation of the projector covers 92 R5905823 HDQ 4K35 30 11 2015 ...
Страница 97: ...A Dimensions and specifications A DIMENSIONS AND SPECIFICATIONS R5905823 HDQ 4K35 30 11 2015 93 ...
Страница 98: ...A Dimensions and specifications 94 R5905823 HDQ 4K35 30 11 2015 ...
Страница 101: ...A Dimensions and specifications Warranty 3 years standard extendable up to 5 years 10 R5905823 HDQ 4K35 30 11 2015 97 ...
Страница 108: ...B Environmental information 104 R5905823 HDQ 4K35 30 11 2015 ...
Страница 110: ...Glossary 106 R5905823 HDQ 4K35 30 11 2015 ...