background image

HIGH DEFINITION MONITOR

HDM 5049 PLUS

USER’S MANUAL

Serial Number:

Edition: May 27

th

, 1999

Part Number: V598958/01

BARCO N.V.

Communication Systems

Th. Sevenslaan 106

B-8500 Kortrijk (Belgium)

Tel.: +32.56.233.211

Fax: + 32.56.233.461

E-mail: [email protected]

Web site: http://www.barco.com

Содержание HDM 5049 PLUS

Страница 1: ...SER S MANUAL Serial Number Edition May 27 th 1999 Part Number V598958 01 BARCO N V Communication Systems Th Sevenslaan 106 B 8500 Kortrijk Belgium Tel 32 56 233 211 Fax 32 56 233 461 E mail support bc...

Страница 2: ......

Страница 3: ...Conditions 3 3 4 OPERATION AND ADJUSTMENT 4 1 4 1 USING THE KEYBOARD 4 1 4 2 MAIN MENU 4 2 4 3 STATUS MENU 4 2 4 4 SETTINGS MENU 4 2 4 4 1 Modename 4 3 4 4 2 AKB 4 3 4 4 3 Orbiter 4 3 4 4 4 Degauss ra...

Страница 4: ......

Страница 5: ...communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 1 2 Powe...

Страница 6: ......

Страница 7: ...dard features are 16 9 aspect ratio 19 picture tube 17 visible Occupies only 8 RU space in a 19 rack Superfine dot pitch of 0 26 mm Small spot size over the entire screen Automatically adjusts to diff...

Страница 8: ......

Страница 9: ...d be mounted in a 19 rack Four retaining screws in the handles keep the monitor in place Do not cover or block the ventilation openings in the cover 3 3 Signal Connection SERVICE 75E R G B HS CS VS PO...

Страница 10: ...Lines Frame Lines 525 750 1125 1125 Active Lines Field Lines 517 5 540 Active Field Time ms 15 33 16 Blanking Lines Field Lines 45 22 5 Blanking Time Field ms 1 33 0 67 Total Lines Field Lines 562 5 5...

Страница 11: ...ition 9 9 OK 10 Clamping problem Remove HS condition 7 11 No vertical sync due to addition of two opposite pulses Clamping problem Remove VS to solve Vert Sync problem and Remove HS because no vertica...

Страница 12: ......

Страница 13: ...Use to reveal remove the Contrast setting Adjust with or Press both keys simultaneously to return to the calibrated value Brightness Use to reveal remove the Brightness setting Adjust with or Press bo...

Страница 14: ...nu Depending on the resolution of the input signal the middle part of this menu is split into two parts that are displayed alternately Press to leave the Status menu The menu disappears automatically...

Страница 15: ...AKB On Off or Auto The AKB system guarantees color stability by changing the DC levels of the RGB cathode drive signals in order to keep the light output of the AKB measuring lines constant Note that...

Страница 16: ...te level Press or to change the light output from 60 to 120 cd m nit in steps of 1 cd m This setting is also used during automatic color temperature alignment Leave the menu with 4 4 7 Change password...

Страница 17: ...ait 10 seconds or press the password entrance menu reappears Select a submenu with or and press to enter Press to leave the Adjustments menu 4 5 1 Color Select manual or automatic color alignment with...

Страница 18: ...PM 5639 01 kit or the combined PM 5639 02 and PM 5639 62 kits To align the HDM 5049 PLUS proceed as follows With Thoma Color Analyzer 1 Connect the Thoma TMF3 or TMF6 Color Analyzer to the Service co...

Страница 19: ...ys following message Press to return to the Color menu If alignment failed the HDM 5049 PLUS displays following message Press to return to the Color menu The old alignment values are restored An align...

Страница 20: ...ss to leave the Geometry menu If changes have been made you will be asked to save or to discard these changes Press to select yes or no then press Horizontal Size Horizontal Position Vertical Size Ver...

Страница 21: ...of the earth s magnetic field The vertical component causes a horizontal deviation of the electron beam The compensation is a DC current through the degauss coils in the top and bottom of the monitor...

Страница 22: ...In the Information Menu you can find the serial number the part number the software number and version and the time the monitor has been running since it left the factory Press to leave the menu The...

Страница 23: ...rlaced SMPTE 296M 480L x 704P 60 Hz Non interlaced SMPTE 293M VIVALDI 525 lines 60Hz 4 Pictures Mode VIVALDI 525 lines 60Hz 1 Picture Full Screen Mode VISUAL PERFORMANCE Picture tube Dot In Line diago...

Отзывы: