5. Troubleshooting
Code 8521: “Tilt rotation not allowed” (Error)
This error code is probably preceded by the warning code 8520: “Tilt rotation not allowed”. The same troubleshooting table can be
applied to.
Code 8550: “Lamp runtime message exceeded” (Warning)
Situation
Solution
The lamp inside the lamp house is
about to exceed its maximum run
time.
Replace the lamp as soon as possible. See "Removing the xenon lamp from the lamp
house", page 123.
Code 8551: “Lamp runtime warning exceeded” (Warning)
Situation
Solution
The lamp inside the lamp house is
about to exceed its maximum run
time. This is a second warning.
Replace the lamp as soon as possible. See "Removing the xenon lamp from the lamp
house", page 123.
Code 8552: “Lamp runtime maximum exceeded” (Warning)
Situation
Solution
The lamp inside the lamp house has
exceeded its maximum run time.
Replace the lamp immediately. See "Removing the xenon lamp from the lamp house",
page 123.
Code 8553: “Lamp runtime shutdown exceeded” (Warning)
Situation
Solution
The lamp inside the lamp house has
exceeded its maximum run time.
Shutdown the projector immediately. Replace the lamp prior to restart the projector. See
"Removing the xenon lamp from the lamp house", page 123.
Code 8600: “Check cooling liquid level” (Warning)
Situation
Solution
One of more DMDs have a high
temperature.
1.
Check the level of the liquid cooling. Add cooling liquid if appropriate. See "Liquid
cooling circuit", page 239.
2.
Check dust
fi
lters. Ensure that the projector air inlets are not blocked.
3.
Make sure that the ambient temperature is within specs: lower then 40°C (104°F).
Code 8601: “Check dust
fi
lters” (Warning)
Situation
Solution
Filthy dust
fi
lter causes a too high
DMD temperature.
Replace a
fi
lthy dust
fi
lter with a new one.
Code 8602: “Check air
fl
ow” (Warning)
Situation
Solution
A blocked air inlet causes a too high
Lamp House temperature.
Ensure that the air inlet at the left lower front of the projector is not blocked.
Code 8603: “Overtemperature dimming” (Warning)
Situation
Solution
The projector has automatically
reduced the lamp power due to too
high internal temperatures.
Check for error/warning messages in the projector noti
fi
cations to
fi
nd the precise cause
of the over temperature.
Code 8604: “Check cooling liquid level every 6 months” (Warning)
Situation
Solution
Six months between last servicing.
•
Check the level of the liquid cooling. Add cooling liquid if appropriate. See "Liquid
cooling circuit", page 239
•
Ensure that all preventative maintenance actions are done. See service manual
chapter "Preventative maintenance actions", page 19.
88
R5905312 HDF W SERIES 24/01/2013
Содержание HDF W series
Страница 1: ...HDF W series Service manual R5905312 01 24 01 2013 ...
Страница 4: ......
Страница 8: ...Table of contents 4 R5905312 HDF W SERIES 24 01 2013 ...
Страница 12: ...1 Safety 8 R5905312 HDF W SERIES 24 01 2013 ...
Страница 30: ...3 Preventative maintenance actions 26 R5905312 HDF W SERIES 24 01 2013 ...
Страница 35: ...5 Troubleshooting 5 TROUBLESHOOTING R5905312 HDF W SERIES 24 01 2013 31 ...
Страница 36: ...5 Troubleshooting 32 R5905312 HDF W SERIES 24 01 2013 ...
Страница 110: ...6 Removal and installation of the projector covers 106 R5905312 HDF W SERIES 24 01 2013 ...
Страница 111: ...7 Power Input 7 POWER INPUT R5905312 HDF W SERIES 24 01 2013 107 ...
Страница 112: ...7 Power Input 108 R5905312 HDF W SERIES 24 01 2013 ...
Страница 120: ...7 Power Input 116 R5905312 HDF W SERIES 24 01 2013 ...
Страница 172: ...10 Card Cage 168 R5905312 HDF W SERIES 24 01 2013 ...
Страница 182: ...11 Lamp Power Supply 178 R5905312 HDF W SERIES 24 01 2013 ...
Страница 183: ...12 Start Pulse Generator 12 START PULSE GENERATOR R5905312 HDF W SERIES 24 01 2013 179 ...
Страница 184: ...12 Start Pulse Generator 180 R5905312 HDF W SERIES 24 01 2013 ...
Страница 192: ...12 Start Pulse Generator 188 R5905312 HDF W SERIES 24 01 2013 ...
Страница 242: ...14 Lenses and Lens Holder 238 R5905312 HDF W SERIES 24 01 2013 ...
Страница 266: ...15 Liquid cooling circuit Image 15 39 Electrical connection 262 R5905312 HDF W SERIES 24 01 2013 ...
Страница 269: ...15 Liquid cooling circuit Image 15 45 Electrical connection R5905312 HDF W SERIES 24 01 2013 265 ...
Страница 270: ...15 Liquid cooling circuit 266 R5905312 HDF W SERIES 24 01 2013 ...
Страница 274: ...16 Heat exchanger Image 16 5 Remove assembly 270 R5905312 HDF W SERIES 24 01 2013 ...
Страница 280: ...16 Heat exchanger Image 16 13 276 R5905312 HDF W SERIES 24 01 2013 ...
Страница 309: ...19 Board Diagnostic LED s 19 BOARD DIAGNOSTIC LED S R5905312 HDF W SERIES 24 01 2013 305 ...
Страница 310: ...19 Board Diagnostic LED s 306 R5905312 HDF W SERIES 24 01 2013 ...
Страница 328: ...19 Board Diagnostic LED s 324 R5905312 HDF W SERIES 24 01 2013 ...