8. Lamp and lamp house
8.7
Realignment of the lamp in its re
fl
ector
Each xenon lamp installation requires a realignment of the lamp in its re
fl
ector for optimal performance of the
xenon lamp in the projector. Furthermore, it is recommended to realign the Z-axis of the lamp after the
fi
rst
run time of 100 and 200 hours.
This procedure assumes that the lamp house with xenon lamp is already installed in the projector and that the
lamp house is equipped with thumbscrews for XYZ-aligment. Use a 2 mm Allen key in case no thumbscrews
are installed.
W
ARNING
:
This procedure may only be performed by quali
fi
ed technical service personnel.
Necessary tools
Light meter
How to align
1. Remove the cover of the lamp compartment to gain access to the X-, Y-, and Z-axis adjustment screws of the lamp.
2. Place a light meter in the center of the projection screen.
3. Loosen the locking screws x, y and z.
4. Switch on the projector and start up the lamp.
5. Adjust the X-axis, the Y-axis and the Z-axis for maximum light output. Carefully turn the thumbscrew for maximum light output.
Once over the maximum, turn slightly in opposite direction to reach the maximum light output again.
Do this for each direction and repeat this adjustment cycle twice.
X
Y
Z
y
x
z
Image 8-31
Lamp alignment
6. Turn the lock nuts against the plate to secure the current position.
7. Switch off the projector and reinstall the cover of the lamp compartment.
R5905312 HDF W SERIES 24/01/2013
135
Содержание HDF W series
Страница 1: ...HDF W series Service manual R5905312 01 24 01 2013 ...
Страница 4: ......
Страница 8: ...Table of contents 4 R5905312 HDF W SERIES 24 01 2013 ...
Страница 12: ...1 Safety 8 R5905312 HDF W SERIES 24 01 2013 ...
Страница 30: ...3 Preventative maintenance actions 26 R5905312 HDF W SERIES 24 01 2013 ...
Страница 35: ...5 Troubleshooting 5 TROUBLESHOOTING R5905312 HDF W SERIES 24 01 2013 31 ...
Страница 36: ...5 Troubleshooting 32 R5905312 HDF W SERIES 24 01 2013 ...
Страница 110: ...6 Removal and installation of the projector covers 106 R5905312 HDF W SERIES 24 01 2013 ...
Страница 111: ...7 Power Input 7 POWER INPUT R5905312 HDF W SERIES 24 01 2013 107 ...
Страница 112: ...7 Power Input 108 R5905312 HDF W SERIES 24 01 2013 ...
Страница 120: ...7 Power Input 116 R5905312 HDF W SERIES 24 01 2013 ...
Страница 172: ...10 Card Cage 168 R5905312 HDF W SERIES 24 01 2013 ...
Страница 182: ...11 Lamp Power Supply 178 R5905312 HDF W SERIES 24 01 2013 ...
Страница 183: ...12 Start Pulse Generator 12 START PULSE GENERATOR R5905312 HDF W SERIES 24 01 2013 179 ...
Страница 184: ...12 Start Pulse Generator 180 R5905312 HDF W SERIES 24 01 2013 ...
Страница 192: ...12 Start Pulse Generator 188 R5905312 HDF W SERIES 24 01 2013 ...
Страница 242: ...14 Lenses and Lens Holder 238 R5905312 HDF W SERIES 24 01 2013 ...
Страница 266: ...15 Liquid cooling circuit Image 15 39 Electrical connection 262 R5905312 HDF W SERIES 24 01 2013 ...
Страница 269: ...15 Liquid cooling circuit Image 15 45 Electrical connection R5905312 HDF W SERIES 24 01 2013 265 ...
Страница 270: ...15 Liquid cooling circuit 266 R5905312 HDF W SERIES 24 01 2013 ...
Страница 274: ...16 Heat exchanger Image 16 5 Remove assembly 270 R5905312 HDF W SERIES 24 01 2013 ...
Страница 280: ...16 Heat exchanger Image 16 13 276 R5905312 HDF W SERIES 24 01 2013 ...
Страница 309: ...19 Board Diagnostic LED s 19 BOARD DIAGNOSTIC LED S R5905312 HDF W SERIES 24 01 2013 305 ...
Страница 310: ...19 Board Diagnostic LED s 306 R5905312 HDF W SERIES 24 01 2013 ...
Страница 328: ...19 Board Diagnostic LED s 324 R5905312 HDF W SERIES 24 01 2013 ...