background image

Command Description

Platforms

Operations 

supported

Level

Value

Target

Comments

POWR

Power                          

GP3, GP4

Get, Set

End User

0 - power off, 1 - power on

POST

Power state

GP3, GP4

Get

End User

See value table POST

IABS

Set source abs values

GP3, GP4

Get, Set

End User

See value table IABS

IDVI

Select DVI

GP3, GP4

Get, Set

End User

1 - DVI 1, 2 - DVI 2

IHDM

Select HDMI

GP3, GP4

Get, Set

End User

1 - HDMI 1, 2  - HDMI 2

IVGA

Select VGA

GP3, GP4

Get, Set

End User

1 - VGA 1, 2 - VGA 2

IDHD

Select dual head DVI

GP3, GP4

Get, Set

End User

IDHH

Select dual head HDMI

GP3, GP4

Get, Set

End User

IDHX

Select dual head XP2

GP3, GP4

Get, Set

End User

IXP2

Select XP2

GP3, GP4

Get, Set

End User

IYPP

Select component

GP3, GP4

Get, Set

End User

ISTS

Signal Status

GP3, GP4

Get

End User

0 - searching 1 - locked to 
source

BRIG

Brightness                     

GP3, GP4

Get, Set

End User

CNTR

Contrast

GP3, GP4

Get, Set

End User

CSAT

Saturation

GP3, GP4

Get, Set

End User

PRST

Picture Reset                  

GP3, GP4

Get, Set

End User

PMUT

Picture Mute

GP3, GP4

Get, Set

End User

0 - disable, 1 - enable

SABS

Set Scaling abs value 

GP3, GP4

Get, Set

End User

See value table SABS

S1T1

Select Scaling 1:1

GP3, GP4

Get, Set

End User

S169

Select Scaling 16:9

GP3, GP4

Get, Set

End User

SS43

Select Scaling 4:3

GP3, GP4

Get, Set

End User

SFLA

Select Scaling Fill All

GP3, GP4

Get, Set

End User

SFAR

Select Scaling Fill Aspect Ratio

GP3, GP4

Get, Set

End User

S235

Select Scaling Fill 2.35:1

GP3, GP4

Get, Set

End User

SANL

Select Scaling Anamorphic Lens

GP3, GP4

Get, Set

End User

AUTO

Auto adjust current source

GP3, GP4

Set

End User

FRZE

Freeze Image

GP3, GP4

Get, Set

End User

0 - disable, 1 - enable

GAFI

Select Gamma Film 

GP3, GP4

Get, Set

End User

1 - Film 1, 2 - Film 2

GAVI

Select Gamma Video

GP3, GP4

Get, Set

End User

1 - Video 1, 2 - Video2

GACO

Select Gamma Computer

GP3, GP4

Get, Set

End User

1 - Computer 1, 2 - Computer 
2

GABS

Set Gamma abs value

GP3, GP4

Get, Set

End User

See value table GABS

CTWP

Color Management Processed 
Test Patterns

GP3, GP4

Get, Set

End User

RCMN

Color management Reset to 
Native

GP3, GP4

Set

End User

RWHN

Color Management reset white to 
native

GP3, GP4

Set

End User

ACAL

AD calibration                 

GP3, GP4

Set

End User

Picture->Calibration

Picture

Picture->RealColor

Source selection

Power

3. ASCII Command Sets

601-0381-00_GP3/GP4 

Sicilium_1_24

6

All manuals and user guides at all-guides.com

Содержание F35

Страница 1: ...F L 35 FS35 IR F85 ASCII Commands Protocol Reference Manual 601 0381 00 00 21 10 2015 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...tad AS Habornveien 53 N 1630 Gamle Fredrikstad Norway Phone 47 6930 4550 Fax 47 6930 4580 Support Support fre barco com Visit us at the web www barco com Printed in NO All manuals and user guides at a...

Страница 3: ...his publication The latest edition of Barco manuals can be downloaded from the Barco web site www barco com or from the secured Barco web site https www barco com en signin Copyright All rights reserv...

Страница 4: ...All manuals and user guides at all guides com...

Страница 5: ...for the projector to receive IP settings from the DHCP server The IP address will be updated and shown in the OSD If there is no DHCP server in the network the projector will be assigned a zero confi...

Страница 6: ...1 Communication settings Maximum length of the RS 232 cable is 15 25m 50ft 2 601 0381 00 F L 35 FS35 IR F85 21 10 2015 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 7: ...seconds delay required 2 2 Serial Communications Protocol Definitions Like every communication method the serial communication uses a particular protocol ANSI which must be respected in order to allo...

Страница 8: ...s sent back The ACK command uses the following protocol Ack Address Separator Command Separator Value Terminator Limitations 1 byte 1 3 bytes 1 byte 4 bytes 1 byte 6 bytes 1 byte Definition ASCII Proj...

Страница 9: ...ption CNTR R1 CR Increase contrast 001 CNTR 000061 CR Acknowledge increase contrast Command Description CNTR R 2 CR Decrease contrast 001 CNTR 000059 CR Acknowledge decrease contrast SET commands with...

Страница 10: ...Set End User See value table SABS S1T1 Select Scaling 1 1 GP3 GP4 Get Set End User S169 Select Scaling 16 9 GP3 GP4 Get Set End User SS43 Select Scaling 4 3 GP3 GP4 Get Set End User SFLA Select Scalin...

Страница 11: ...inate CMXV Color Management X Coordinate GP3 GP4 Get Set End User CMYV Color Management Y Coordinate GP3 GP4 Get Set End User CMTV Color Management Temperature GP3 GP4 Get Set End User 3200 9300 RD65...

Страница 12: ...Factory Desired White Gain GP3 GP4 Get Set Manufacturing MSRX Measured Red X GP3 GP4 Get Set End User MSRY Measured Red Y GP3 GP4 Get Set End User MSRL Measured Red Luminance GP3 GP4 Get Set End User...

Страница 13: ...GP4 Get Set End User DESK Select orientation Desktop Front GP3 GP4 Get Set End User CEIL Select orientation Ceiling Front GP3 GP4 Get Set End User RDES Select orientation Desktop Rear GP3 GP4 Get Set...

Страница 14: ...Frame lock 2 Pass through FLST Frame lock Status GP3 GP4 Get End User Print current frame lock status TSLR 3D source L R sync GP3 GP4 Get Set End User 0 None 1 BNC sync in TDLR 3D display L R sync GP3...

Страница 15: ...End User 0 disable 1 enable DISL RGB LEDs enable GP3 LED IR Get Set End User 0 disable 1 enable LDMM LED Dim Mode GP3 LED IR Get Set End User 0 standard 1 custom LPW1 LED Power GP3 Get Set End User LD...

Страница 16: ...IRCL Iris Close GP3 GP4 Set End User 1 Slow 2 Medium 3 Fast LSDW Lens Shift Down GP3 GP4 Set End User 1 Slow 2 Medium 3 Fast LSUP Lens Shift Up GP3 GP4 Set End User 1 Slow 2 Medium 3 Fast LSLF Lens Sh...

Страница 17: ...VCA LED voltage calibration start GP3 LED Set Service Partner LVCS LED voltage calibration status GP3 LED Get Service Partner 0 done 1 in progress 2 failed LVCE LED voltage calibration error code GP3...

Страница 18: ...4 Get Power User Extended Protocol SERI Serial Number String GP3 GP4 Get Power User Extended Protocol MODL Model Name String GP3 GP4 Get Power User Extended Protocol PART Part Number String GP3 GP4 Ge...

Страница 19: ...BP Lamp data mailbox position GP3 Get Set Manufacturing Data 0 Lamp 1 1 Lamp 2 LMBC Lamp data mailbox checksum GP3 Get Set Manufacturing Data 0 Lamp 1 1 Lamp 2 Lamp data 3 ASCII Command Sets 601 0381...

Страница 20: ...p is not present GABS Set Gamma abs value Value Description 0 Film 2 2 1 Film 2 8 2 Video 1 3 Video 2 4 Film 2 4 5 Film 2 6 7 Computer 1 8 Computer 2 9 Linear when available 10 AD calibration when ava...

Страница 21: ...lue Description 0 Off 0 Off 0 VizSim 1 Computer balanced 1 Video 1 High Brightness 2 Video balanced 2 SRP Full when available 2 SRP 8ms 3 Computer native 3 Computer 3 Graphics 4 Video native 4 SRP Hal...

Страница 22: ...e 0 4 3 1 5 4 on 0 2 16 9 off 1 3 16 10 no change 2 4 2 35 1 5 no source 6 standby EDIR Edid resolution Target Description Value Auto 0 Custom not implemented 1 VGA 2 SVGA 3 XGA 4 720 50Hz 5 720 60Hz...

Страница 23: ...ck signal status Value Description 0 free running 3 locked TDSS 3D LR Signal status Value Description 0 free running 1 drifting free running 2 drifting locked 3 locked TDSM 3D stereo mode Value Descri...

Страница 24: ...d blue drop out voltage failed 23 Desired blue input voltage out of range 24 Blue loop count exceed max value INCE bit wise error code for LED sensor calibration Bit Description 0 Write red sensor dur...

Отзывы: