R5906848 /04
DP2K SLP Series
362
Code 20379:
“
LDM 1-2
–
heatsink rectifier temperature sensor open
”
Situation
Solution
Malfunction LDM board
Replace the LDM board. See service procedure
”
, page 48.
Code 20383:
“
LDM 1-2
–
Heatsink drain temperature too high
”
For this error the same troubleshooting table can be applied to as for code
20377
:
“
LDM 1-2
–
Heatsink
rectifier temperature too high
”
.
Code 20384:
“
LDM 1-2
–
Heatsink drain temperature sensor shorted
”
For this error the same troubleshooting table can be applied to as for code
20378
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor shorted
”
.
Code 20385:
“
LDM 1-2
–
Heatsink drain temperature sensor open
”
For this error the same troubleshooting table can be applied to as for code
20379
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor open
”
.
Code 20386:
“
LDM 1-2
–
Bad Communication
”
Situation
Solution
Difference in software
packages.
Upgrade the software. See procedure
“
Software update via Communicator
”
There are other
communication errors,
including LDM 1
communication errors.
Solve LDM 1 communication errors first.
There are several LDM 1
–
x
communication errors
•
Make sure that all LDM boards are properly seated in the LDM case.
•
If problem persists, replace the LDM. See service procedure
, page 56.
Code 20387:
“
LDM 1-2
–
No Communication
”
Situation
Solution
First install of Laser Driver
Module
Upgrade the software. See procedure
“
Software update via Communicator
”
There are other
communication errors,
including LDM 1
communication errors.
Solve LDM 1 communication errors first.
There are several LDM 1
–
x
communication errors
•
Make sure that all LDM boards are properly seated in the LDM case.
•
If problem persists, replace the LDM. See service procedure
, page 56.
Code 20391:
“
LDM 1-2
–
Bad Communication
”
For this error the same troubleshooting table can be applied to as for code
20386
:
“
LDM 1
–
Bad
Communication
”
.
Code 20392:
“
LDM 1-2
–
No Communication
”
For this error the same troubleshooting table can be applied to as for code
20387
:
“
LDM 1
–
No
Communication
”
.
Содержание DP2K SLP Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Страница 4: ......
Страница 10: ...R5906848 04 DP2K SLP Series 10 ...
Страница 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Страница 24: ...R5906848 04 DP2K SLP Series 24 General ...
Страница 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Страница 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Страница 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Страница 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Страница 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Страница 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Страница 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Страница 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Страница 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Страница 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Страница 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Страница 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Страница 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Страница 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Страница 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Страница 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Страница 409: ...R5906848 04 DP2K SLP Series 409 ...