Code 5305:
“
DMD green - Temperature sensor short
”
Situation
Solution
Damaged wire insulation of the
temperature sensor which
measures the heat sink
temperature of the green
channel. When disconnecting
the wire of the temperature
sensor from the Signal
Backplane (reference 7
Image 25-58) the error code is
changed to
“
dmd green -
temperature sensor open
”
.
1.
Repair the insulation of the of the temperature sensor which measures
the heat sink temperature of the green channel (reference 17
Image 25-59) .
2.
If not repairable, replace the temperature sensor and wiring.
Defect temperature sensor
(reference 17 Image 25-59)
which measures the heat sink
temperature of the green
channel. When disconnecting
the wire unit of the
temperature sensor from the
Signal Backplane (reference 7
Image 25-58 the error code is
changed to
“
dmd green -
temperature sensor open
”
.
Replace the temperature sensor (reference 17 Image 25-59) which
measures the heat sink temperature of the green channel.
Code 5310:
“
LLS ambient - temperature too high
”
(Error)
This error code is probably preceded by the warning code 5311 :
“
lls ambient- temperature high
”
. The same
troubleshooting table can be applied.
Code 5311:
“
LLS ambient - temperature high
”
(Warning)
Situation
Solution
Ambient temperature too high.
Check the ambient temperature at the air inlets of the projector. Make sure
that the ambient temperature does not exceed 35°C (95°F).
Blocked filters.
Check the projector filters. Clean filthy filters or replace with new ones.
Содержание DP2K SLP Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Страница 4: ......
Страница 10: ...R5906848 04 DP2K SLP Series 10 ...
Страница 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Страница 24: ...R5906848 04 DP2K SLP Series 24 General ...
Страница 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Страница 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Страница 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Страница 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Страница 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Страница 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Страница 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Страница 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Страница 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Страница 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Страница 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Страница 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Страница 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Страница 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Страница 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Страница 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Страница 409: ...R5906848 04 DP2K SLP Series 409 ...