17. Pin configurations
RJ-45 Pin Number
(Left >Right copper
side)
568A
568B
AES -1-8
2
Green
Orange
AES 1&2 +minus
3
White/Orange
White/Green
AES 3&4 +plus
4
Blue
Blue
AES 5&6 +minus
5
White/Blue
White/Blue
AES 5&6 +plus
6
Orange
Green
AES 3&4 +minus
7
White/Brown
White/Brown
AES 7&8 +plus
8
Brown
Brown
AES 7&8 +minus
568A and 568B may be used interchangeably in a system SO LONG AS both ends of a given cable are terminated the same way.
568A + 568B wiring is a crossover cable.
568A + 568A wiring is a straight cable.
568B + 568B wiring is a straight cable.
The mapping of the channels is done according to the Ethernet wiring scheme and gives us 100 Ohm per pair.
17.4 Pin con
fi
gurations of the inputs
DVI-D
DVI IN A & B
1
RX2-
7
DDC Data
13
nc
19
RX0 Shield
2
RX2+
8
nc
14
+5V
20
nc
3
RX2 Shield
9
RX1-
15
GND
21
nc
4
nc
10
RX1+
16
Hot Plug Detect
22
TMDS Clock Shield
5
nc
11
RX1 Shield
17
RX0-
23
TMDS RXC+
6
DDC Clock
12
nc
18
RX0+
24
TMDS RXC-
164
R5906753 DPXK BLP SERIES 20/11/2017
Содержание DP2K-17BLP
Страница 4: ......
Страница 8: ...Table of contents 4 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 30: ...3 Installation process 26 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 40: ...4 Physical installation projector 36 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 120: ...10 Communicator Touch Panel Image 10 7 Connections 116 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 152: ...14 Maintenance 148 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 158: ...15 Convergence Green 1 5 4 6 5 Image 15 8 Green on blue convergence 154 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 162: ...16 Color calibration 158 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 176: ...18 Specifications 172 R5906753 DPXK BLP SERIES 20 11 2017 ...