9. ICMP
9.10 ICMP HDD status LEDs
ICMP HDD status LEDs
5
4
Image 9-10
Status overview PWR/ERROR and READY LEDs:
4
5
HDD I/O
RAID
ICMP HDD Status
Off
Off
HDD idle / Disk in RAID OK.
Blinking Green
Off
HDD I/O activity / Disk in RAID OK.
Blinking Green
Blinking Red
HDD I/O activity / RAID rebuilding.
Off
Red
HDD idle / Disk error. See troubleshooting table below for curative actions.
Troubleshooting
Situation
Solution
One disk failed (red LED) +
RAID degraded
.
The ongoing event is not interrupted.
Note:
The disk status (RAID degraded) can be retrieved via the
(Web) Commander. See user guide of the (Web) Commander.
1.
Switch off the power.
2.
Replace the defect HDD with approved model of the
same storage capacity. See procedure "Removing a HDD
from the ICMP", page 110, and "Installing a HDD into the
ICMP", page 111. Ensure to insert the HDD
fi
rmly.
3.
Switch on the power.
Result:
As soon the new HDD is detected by the ICMP the
rebuild of the RAID is started (Blinking red LED).
One disk failed (red LED) + Error 10580 “
local storage not
available
”.
Note:
The disk status (Error code) can be retrieved via the
(Web) Commander. See user guide of the (Web) Commander.
1.
Switch off the power.
2.
Replace the defect HDD with approved model of the
same storage capacity. See procedure "Removing a HDD
from the ICMP", page 110, and "Installing a HDD into the
ICMP", page 111. Ensure to insert the HDD
fi
rmly.
3.
Switch on the power.
Result:
As soon the new HDD is detected by the ICMP the
rebuild of the RAID is started (Blinking red LED).
Multiple disks failed (multiple red LEDs) +
RAID broken
.
Note:
The disk status (RAID broken) can be retrieved via the
(Web) Commander. See user guide of the (Web) Commander.
1.
Switch off the power.
2.
Replace all defect HDDs with approved models of the
same storage capacity. See procedure "Removing a HDD
from the ICMP", page 110, and "Installing a HDD into the
ICMP", page 111. Ensure to insert the HDDs
fi
rmly.
3.
Switch on the power.
4.
Start “RAID Initialize”. See user guide of the
Communicator.
Result:
a new empty RAID is created.
All HDD LEDs remain off + Error 10580 “
local storage not
available
”.
Note:
The disk status (Error code) can be retrieved via the
(Web) Commander. See user guide of the (Web) Commander.
1.
Switch off the power.
2.
Reseat all HDDs. See procedure "Removing a HDD
from the ICMP", page 110, and "Installing a HDD into the
ICMP", page 111. Ensure to insert the HDDs
fi
rmly.
3.
If problem remains try “RAID Initialize”. See user guide of
the Communicator. Note that all content will be lost!
4.
If problem remains contact Service for further instructions.
108
R5906753 DPXK BLP SERIES 20/11/2017
Содержание DP2K-17BLP
Страница 4: ......
Страница 8: ...Table of contents 4 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 30: ...3 Installation process 26 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 40: ...4 Physical installation projector 36 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 120: ...10 Communicator Touch Panel Image 10 7 Connections 116 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 152: ...14 Maintenance 148 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 158: ...15 Convergence Green 1 5 4 6 5 Image 15 8 Green on blue convergence 154 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 162: ...16 Color calibration 158 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 176: ...18 Specifications 172 R5906753 DPXK BLP SERIES 20 11 2017 ...