![Barco BARCOREALITY 6500 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/barco/barcoreality-6500/barcoreality-6500_owners-manual_473901050.webp)
7. Random Access
Do not adjust these settings on an active file, they are used to identify the input source file.
How to find the correct values for the item in the Edit file menu?
Horizontal Total Pixels
If the value for "Horizontal Total Pixels" is wrong, sampling mistakes (small vertical bars in the
projected image) will be seen in the image.
Select "Total" and adjust the pixel quantity. Adjust for zero bars.
hint: if the number of bars increase, adjust in the other direction.
Active Pixels
The "Active Pixels" : determine the width of the window on the screen. This value is normally given in
the source specifications. If not, adjust until full image is displayed (no missing pixels).
Horizontal Start
number of pixels between the beginning of the input signal and the start of the video information in
the signal.
Horizontal Period
already filled in with the correct value when active file.
Vertical Total Lines
already filled when an active file is selected to be edited
Active Lines
number of horizontal lines determining the height of the projected image. This value is normally given
in the specification of the source. If not, adjust until full image height is displayed (no missing lines)
Vertical Start
number of lines between the start of the input signal and start of the image on the screen.
Interlaced [On] or [Off]
this selection is automatically filled when active file has to be edited. If the image is wrong due to
mismeasurement, use the ENTER key to toggle between [On] and [Off]. (for interlaced images,
1 frame contains 2 fields).
Read AMDS
AMDS = automatic mode detection & synchronization
During the installation of a file with LOAD, the system automatically measured the horizontal period,
the total vertical lines and the interlaced mode. When selecting Read AMDS, the system remeasures
the above indicated items.
How to install the correct settings for the options in the Edit file menu.
EDIT FILE OPTIONS
Source number
1
Clamo position
[leading]
Clamp delay
0
Clamp width
10
Field polarity
[pos]
Field select
[both]
Vertical refresh
[sync]
Vertical sync polarity
[leading]
Select with
↑
or
↓
<ENTER> to toggle
↑
or
↓
to change value
<EXIT> to return.
Menu 7-10
Source number
The source number of a non-active source can be changed to any other source number. This makes
it possible to create a file for future source numbers.
Clamp position
Clamping determines the black level of the signal. The clamp pulse can be related to the leading or
the trailing edge of the sync pulse. Use the
ENTER
key to toggle between [leading] and [trailing].
Clamp delay
The time between the leading edge of the clamp pulse and the locked edge of the sync pulse. Can be
any value between 0 and 255. Change the value by pushing the cursor key
↑
or
↓
.
Clamp width
The width of the clamp pulse can be any value between 0 and 255. Change the value by pushing
the cursor key
↑
or
↓
.
46
R5976182 BARCOREALITY 6500 30012001
Содержание BARCOREALITY 6500
Страница 1: ...INTELLIGENT DISPLAYS BARCOREALITY 6500 R9001960 R9001969 OWNER S MANUAL 30012001 R5976182 01 ...
Страница 4: ......
Страница 8: ...Table of contents 4 R5976182 BARCOREALITY 6500 30012001 ...
Страница 12: ...1 Packaging and Dimensions 8 R5976182 BARCOREALITY 6500 30012001 ...
Страница 20: ...2 Installation Guidelines 16 R5976182 BARCOREALITY 6500 30012001 ...
Страница 42: ...5 Start Up mode 38 R5976182 BARCOREALITY 6500 30012001 ...
Страница 68: ...7 Random Access 64 R5976182 BARCOREALITY 6500 30012001 ...
Страница 90: ...9 Service mode 86 R5976182 BARCOREALITY 6500 30012001 ...
Страница 94: ...A Standard Source Set Up Files 90 R5976182 BARCOREALITY 6500 30012001 ...
Страница 118: ...D Cleaning the Dustfilter 114 R5976182 BARCOREALITY 6500 30012001 ...
Страница 120: ...Glossary 116 R5976182 BARCOREALITY 6500 30012001 ...
Страница 124: ...Index 120 R5976182 BARCOREALITY 6500 30012001 ...
Страница 125: ...List of tables LIST OF TABLES B 2 Overview of possible adjustments 95 R5976182 BARCOREALITY 6500 30012001 121 ...
Страница 126: ...List of tables 122 R5976182 BARCOREALITY 6500 30012001 ...