601
–
0443 /03
Balder
34
3.1 Projector source and control connections
Overview
•
•
•
3.1.1 Making connections
The source switching time is variable and could take few seconds..
Source signal connectivity
The connector panel at the back of the projector is used for all source connections.
Source signal connectivity on the projector is:
•
2x Dual Link DVI-I (DVI-D functionality)
•
2x DisplayPort 1.2
•
1x HDMI 2.0
•
1x HDBaseT
•
1x SDI input (initially designed for 3G-SDI input signals, 12G-SDI signals are now supported)
3.1.2 Connector specifications
Overview
•
•
•
•
•
3.1.2.1 DVI-I
Specifications
Parameter
Value
Connector
DVI-I female digital RGB
Signal characteristics
DVI 1.0, Digital, TMDS
Max. cable length
25 m (24 AWG)
Max. pixel rate
330 MHz (dual link), 165 Mhz (single link)
Scan format
Progressive
Max. input data resolution
1920x1200 60Hz (Single link), 2560x1600 60Hz
(Dual Link).1920x2400 @60Hz
Bit depth
8 bit
EDID
Supported
HDCP
Supported