7.1 Safety information
General recommendations
•
Read the operating manual thoroughly and be familiar with the content, prior to using this equipment.
•
Do not place the monitor, or any other heavy object, on the power cord to prevent fire or electrical shock
from damage to the power cord.
•
Do not expose the monitor to dust to avoid fire or shock hazard.
•
Avoid placing the monitor against a bright background or where sunlight or other light sources may reflect
on the area of the monitor. Place the monitor just below eye level.
•
Handle the monitor with care.
•
Refrain from giving a shock to the monitor.
•
Do not scratch the screen, as the screen is fragile.
Electrical Shock or Fire Hazard
To prevent electric shock or fire hazard, do not remove cover.
No serviceable parts inside. Refer servicing to qualified personnel.
Do not expose this apparatus to rain or moisture.
Modifications to the unit
Do not modify this equipment without authorization of the manufacturer.
Preventive maintenance
Periodic maintenance inspections are essential to keep the monitor in optimum condition and ensure safe
operation.
With the monitor disconnected from the mains, perform the following periodic check:
•
Check the integrity of the power cord and inspect its routing, so that it is not under the risk of being
punched or cut.
•
Check the integrity of the protective earth connection.
•
Clean the area around the power plug. Dust and liquids may result in fire.
•
Clean the ventilation slot of the monitor. Dust can obstruct the air flow and cause temperature increase of
the electronics.
General recommendations:
•
Keep the monitor clean to prolong its operational lifetime.
•
LCD panel performance may deteriorate in the long term. Periodically check that it is correctly operating.
•
Periodically check the tightness of the VESA mount screws. If not sufficiently tight, the monitor may detach
from the arm, which may result in injury or equipment damage.
Type of protection (Electrical)
Equipment with external power supply: Class I equipment
Degree of safety (flammable anesthetic mixture):
•
Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or
nitrous oxide.
•
The equipment shall not be operable when the air oxygen content is above 25%.
Equipment
•
Monitor with power supply is suitable for use in patient environment.
•
This equipment has been tested and found to comply with the limits for medical devices in IEC 60601-1-
2:2014.
•
Equipment with SIP/SOP connectors should either comply with IEC 60601-1 harmonized national standard
or the combination should be evaluated. Do not touch the patient with signal input or output connectors.
Содержание AMM215WTD
Страница 1: ...ENABLING BRIGHT OUTCOMES User Guide LCD color display AMM215WTD...
Страница 4: ...R5912860 13 AMM215WTD 4 7 10 Connectors 45...
Страница 10: ...R5912860 13 AMM215WTD 10 Welcome...
Страница 15: ...15 R5912860 13 AMM215WTD Daily operation 3...
Страница 18: ...R5912860 13 AMM215WTD 18 Daily operation...
Страница 19: ...19 R5912860 13 AMM215WTD Advanced operation 4...
Страница 26: ...R5912860 13 AMM215WTD 26 Advanced operation...
Страница 27: ...27 R5912860 13 AMM215WTD Cleaning your display 5...
Страница 29: ...29 R5912860 13 AMM215WTD Troubleshooting 6...
Страница 31: ...31 R5912860 13 AMM215WTD Important information 7...
Страница 47: ......