PARTS LIST

This list contains replaceable parts used in your log set. When
ordering parts, follow the instructions listed under Replacement
Parts
 on page 22 of this manual.

BVTR24

KEY

PART

NO.

NUMBER

DESCRIPTION

QTY.

1

098249-01

ODS Nut

2

2

901752-01

Rear Burner

1

3

102843-01

Burner Clip

1

4

901246-02

Log Grate

1

5

098304-01

Screw, 10-16 x .38

4

6

901762-01

Burner Bracket

1

7

901754-01

Front Burner

1

8

901753-01

Burner Pan

1

9

901750-01

Nozzle

1

10

901064-01

Natural Gas Injector

1

11

901066-01

Brass Air Mixer - Natural Gas

1

12

901761-01

1/8 Hex Nipple

1

13

901760-01

Manifold Block

1

14

901751-01

Air Restrictor

1

15

901756-01

Valve Cover

1

16

901056-01

Brass Elbow Flare Fitting

1

17

901058-01

Brass 3/8 FLR x 1/2 FPT Adapter

1

18

101628-01

Gas Line - 10" Flex

1

19

901769-01

Ember Bed

1

20

901580-02

Top Log VR-11/VC

1

21

901587-04

Top Log VCR-9/VS

1

22

901528-04

Top Log CS-16/VS

1

23

901540-04

Top Log CS-18/VS

1

24

901579-02

Top Log VR-10Y/VS

1

25

901588-01

Top Log VS-12

1

26

901532-03

Bottom Log CS-24/VS

1

27

901759-01

Manifold Plug

1

PARTS AVAILABLE — NOT SHOWN

901036-01

RADCO GEN Rating Plate

1

109462-05

Rating Information Plate

1

901242-01

Damper Clamp

1

CDABKA

Decorative Ash Bed Control Cover

1

GA9360A

Ornamental Grate Enhancer

1

PARTS LIST

BVTR24

Содержание BVTR18

Страница 1: ...orassis tanceoradditionalinformationcon sult a qualified installer service agency or the gas supplier WARNING This appliance is for installation only in a solid fuel burning masonry or UL127 fac tory...

Страница 2: ...ctions if you cannot reach your gas supplier call the fire department 3 Never install the log set in a recreational vehicle where curtains furniture clothing or other flammable ob jects are less than...

Страница 3: ...pan The data plates contain important product and warranty information 1 Removelogs hearthkit panmaterials andhardwarefromcarton 2 Remove all protective packaging applied to logs and base for shipment...

Страница 4: ...ugh fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is defined as construction where a...

Страница 5: ...s Example Gas water heater 40 000 Btu Hr Gas fireplace logs 55 000 Btu Hr Total 95 000 Btu Hr AIR FOR COMBUSTION AND VENTILATION Continued WARNING If the area in which the appliance may be operated is...

Страница 6: ...Figure 2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANS Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation for required size of ven...

Страница 7: ...he specificationsshownareapplicablebeforeinstallationisattempted The fireplace must include a working flue and venting system with the minimum openings shown in the Figure 4 MODEL DESCRIPTION BVTR18 1...

Страница 8: ...ply pipe joint sealant lightly to male NPT threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in a clogged burner injector WARNING Use pipe joint sealant...

Страница 9: ...l the rear burner bracket onto the grate with the 2 black Phillips head 10 screws provided Do not tighten at this time see Figure 9 Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipm...

Страница 10: ...supply fitting Carefully shape tube to attach to adapter fitting Close Pipe Nipple Gas Control Valve Manifold Block Figure 11 Installing Gas Control Valve Control Rod INSTALLATION Continued 6 Place t...

Страница 11: ...Burner Inlet Fitting with Injectors NATURAL GAS BURNER INLET FITTING Injector for Natural Gas Figure 15 Kit Assembly Burner Inlet Fitting Front Burner Pipe Nipple Air Restrictor Manifold Block Rear Bu...

Страница 12: ...ith the red stripe 3 Replace and tighten the pilot line to the bracket 4 Continue with step 3 under Natural Gas Installation page 10 TESTING BURNER FOR LEAKS 1 Generously apply noncorrosive leak detec...

Страница 13: ...n to the next step 4 Light a match and lay it on top of the U shaped burner near the edge of the cover on the right side of the pan 5 Slowly turn the gas shutoff valve ON until the burner ig nites If...

Страница 14: ...plier for repairs 6 With control knob pressed in push down and release igni tor button This will light pilot The pilot is attached to the rear of the front burner If needed keep pressing ignitor butto...

Страница 15: ...carbon soot where flames contact the logs This is especially true with propane LP gas Burner is excessively noisy Note Themovementandcombustionofgas will create low unavoidable levels of noise Burner...

Страница 16: ...1 Clean burner orifice 2 Contact local natural or propane LP gas company 3 Replace burner orifice 4 Reconnect leads 1 Adjust pilot flame for approximately 2 blue flame 2 Replace pilot orifice set 1 T...

Страница 17: ...LEM Log set produces a clicking ticking noise just after burner is lit or shut off Log set produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY...

Страница 18: ...109484 18 ILLUSTRATED PARTS BREAKDOWN BVTR18 4 19 21 22 20 23 24 25 2 3 8 7 11 10 1 5 6 15 9 14 12 13 26 16 18 5 17 ILLUSTRATED PARTS BREAKDOWN BVTR18...

Страница 19: ...Natural Gas 1 12 901761 01 1 8 Hex Nipple 1 13 901760 01 Manifold Block 1 14 901751 01 Air Restrictor 1 15 901756 01 Valve Cover 1 16 901056 01 Brass Elbow Flare Fitting 1 17 901058 01 Brass 3 8 FLR x...

Страница 20: ...109484 20 ILLUSTRATED PARTS BREAKDOWN BVTR24 4 19 23 21 22 20 24 25 26 2 3 8 7 11 10 1 5 6 15 9 14 12 13 27 16 18 5 17 ILLUSTRATED PARTS BREAKDOWN BVTR24...

Страница 21: ...12 901761 01 1 8 Hex Nipple 1 13 901760 01 Manifold Block 1 14 901751 01 Air Restrictor 1 15 901756 01 Valve Cover 1 16 901056 01 Brass Elbow Flare Fitting 1 17 901058 01 Brass 3 8 FLR x 1 2 FPT Adapt...

Страница 22: ...analsowritetotheaddresslistedonthebackpage of this manual EQUIPMENT SHUTOFF VALVE GA5010 For all models Equipment shutoff valve with 1 8 NPT tap Fits 1 2 NPT pipe RECEIVER AND HAND HELD REMOTE CON TRO...

Страница 23: ..._______________________________________ __________________________________________________________________ __________________________________________________________________ __________________________...

Страница 24: ...nce with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become...

Отзывы: