background image

WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any
other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the

fire department.

— Installation and service must be performed by a

qualified installer, service agency, or the gas
supplier.

WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For assis-
tance or additional information con-
sult a qualified installer, service
agency, or the gas supplier.

WARNING: This appliance is for
installation only in a solid-fuel
burning masonry or UL127 fac-
tory-built fireplace, constructed of
noncombustible material, and con-
nected to a working flue. (See page
7 for minimum flue opening.)

WARNING: This is a gas-fired appliance. It uses air (oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation air must be provided. Refer to 

Air for

Combustion and Ventilation section on page 4 of this manual.

Models BVTR18

and BVTR24

RGA 2-72

APPROVED

FOR USE WITH

CANYON SPLIT LOG SETS

INCLUDED WITH HEARTH KITS

TESTED AND

LISTED BY

Std RADCO Listing No. 1292

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not
prohibited by state or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

NATURAL GAS LOG
VENTED DECORATIVE APPLIANCE

OWNER’S MANUAL

Save this manual for future reference.

Save this manual for future reference.

Содержание BVTR18

Страница 1: ...orassis tanceoradditionalinformationcon sult a qualified installer service agency or the gas supplier WARNING This appliance is for installation only in a solid fuel burning masonry or UL127 fac tory...

Страница 2: ...ctions if you cannot reach your gas supplier call the fire department 3 Never install the log set in a recreational vehicle where curtains furniture clothing or other flammable ob jects are less than...

Страница 3: ...pan The data plates contain important product and warranty information 1 Removelogs hearthkit panmaterials andhardwarefromcarton 2 Remove all protective packaging applied to logs and base for shipment...

Страница 4: ...ugh fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is defined as construction where a...

Страница 5: ...s Example Gas water heater 40 000 Btu Hr Gas fireplace logs 55 000 Btu Hr Total 95 000 Btu Hr AIR FOR COMBUSTION AND VENTILATION Continued WARNING If the area in which the appliance may be operated is...

Страница 6: ...Figure 2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANS Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation for required size of ven...

Страница 7: ...he specificationsshownareapplicablebeforeinstallationisattempted The fireplace must include a working flue and venting system with the minimum openings shown in the Figure 4 MODEL DESCRIPTION BVTR18 1...

Страница 8: ...ply pipe joint sealant lightly to male NPT threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in a clogged burner injector WARNING Use pipe joint sealant...

Страница 9: ...l the rear burner bracket onto the grate with the 2 black Phillips head 10 screws provided Do not tighten at this time see Figure 9 Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipm...

Страница 10: ...supply fitting Carefully shape tube to attach to adapter fitting Close Pipe Nipple Gas Control Valve Manifold Block Figure 11 Installing Gas Control Valve Control Rod INSTALLATION Continued 6 Place t...

Страница 11: ...Burner Inlet Fitting with Injectors NATURAL GAS BURNER INLET FITTING Injector for Natural Gas Figure 15 Kit Assembly Burner Inlet Fitting Front Burner Pipe Nipple Air Restrictor Manifold Block Rear Bu...

Страница 12: ...ith the red stripe 3 Replace and tighten the pilot line to the bracket 4 Continue with step 3 under Natural Gas Installation page 10 TESTING BURNER FOR LEAKS 1 Generously apply noncorrosive leak detec...

Страница 13: ...n to the next step 4 Light a match and lay it on top of the U shaped burner near the edge of the cover on the right side of the pan 5 Slowly turn the gas shutoff valve ON until the burner ig nites If...

Страница 14: ...plier for repairs 6 With control knob pressed in push down and release igni tor button This will light pilot The pilot is attached to the rear of the front burner If needed keep pressing ignitor butto...

Страница 15: ...carbon soot where flames contact the logs This is especially true with propane LP gas Burner is excessively noisy Note Themovementandcombustionofgas will create low unavoidable levels of noise Burner...

Страница 16: ...1 Clean burner orifice 2 Contact local natural or propane LP gas company 3 Replace burner orifice 4 Reconnect leads 1 Adjust pilot flame for approximately 2 blue flame 2 Replace pilot orifice set 1 T...

Страница 17: ...LEM Log set produces a clicking ticking noise just after burner is lit or shut off Log set produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY...

Страница 18: ...109484 18 ILLUSTRATED PARTS BREAKDOWN BVTR18 4 19 21 22 20 23 24 25 2 3 8 7 11 10 1 5 6 15 9 14 12 13 26 16 18 5 17 ILLUSTRATED PARTS BREAKDOWN BVTR18...

Страница 19: ...Natural Gas 1 12 901761 01 1 8 Hex Nipple 1 13 901760 01 Manifold Block 1 14 901751 01 Air Restrictor 1 15 901756 01 Valve Cover 1 16 901056 01 Brass Elbow Flare Fitting 1 17 901058 01 Brass 3 8 FLR x...

Страница 20: ...109484 20 ILLUSTRATED PARTS BREAKDOWN BVTR24 4 19 23 21 22 20 24 25 26 2 3 8 7 11 10 1 5 6 15 9 14 12 13 27 16 18 5 17 ILLUSTRATED PARTS BREAKDOWN BVTR24...

Страница 21: ...12 901761 01 1 8 Hex Nipple 1 13 901760 01 Manifold Block 1 14 901751 01 Air Restrictor 1 15 901756 01 Valve Cover 1 16 901056 01 Brass Elbow Flare Fitting 1 17 901058 01 Brass 3 8 FLR x 1 2 FPT Adapt...

Страница 22: ...analsowritetotheaddresslistedonthebackpage of this manual EQUIPMENT SHUTOFF VALVE GA5010 For all models Equipment shutoff valve with 1 8 NPT tap Fits 1 2 NPT pipe RECEIVER AND HAND HELD REMOTE CON TRO...

Страница 23: ..._______________________________________ __________________________________________________________________ __________________________________________________________________ __________________________...

Страница 24: ...nce with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become...

Отзывы: