background image

www.desatech.com

901746-01E

15

INSPECTING BURNERS 

Thermocouple

Figure 23 - Correct Pilot Flame Pattern

Pilot

Check  pilot  flame  pattern  and  burner flame 
patterns often.

PILOT ASSEMBLy

The pilot assembly is factory preset for proper 
flame height. Alterations may have occurred 
during  shipping  and  handling.  The  pilot  is 
located on back right hand side of burner.
The thermocouple should be fully enveloped 
in flame. Flame should not be lifting off ther

-

mocouple element.
If  your  pilot  assembly  does  not  meet  these 
requirements:
•  Access  pilot  adjustment  screw  through 

slot in valve cover. Turn adjustment screw 
clockwise to decrease or counterclockwise 
to increase flame to proper size (see Figure 
17, page 11). Do not remove adjustment 
screw.

•  see 

Troubleshooting

, page 16

BURNER FLAME PATTERN

Burner  flames  will  be  steady;  not  lifting  or 
floating.  Flames  should  go  up  through  the 
middle of log set. Flames should not "spill" to 
edges of pan or sides of log set.
Figure  24  shows  a  typical  flame  pattern.  If 
burner  flame  pattern  differs  from  that  de

-

scribed:
•  turn appliance off (see 

To Turn Off Gas to 

Appliance, 

page 14) 

•  see 

Troubleshooting

, page 16

Figure 24 - Typical Flame Pattern

CLEANING AND MAINTENANCE

•  Keep area around log set clean and clear 

of debris.

•  Occasionally,  you  may  use  a  soft  bristle 

brush to clean logs.

•  Periodically  inspect  air  mixer  and  burner 

tube  for  foreign  matter  blocking  air  inlet 
and flame holes.

•  Once  every  year  a  qualified  agency  or 

certified  chimney  sweep  should  examine 
and clean venting system of fireplace.

Содержание BVDR18

Страница 1: ...ctrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depa...

Страница 2: ...you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Improper instal lation adjustment alteration service or maint...

Страница 3: ...Cleaning and Maintenance page 11 safety Continued 8 Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alter bu...

Страница 4: ...A Heating LLC at 1 866 672 6040 for replacement parts before returning to dealer ON OFF Safety Valve Pilot kit and Propane lp conversion An optional valve safety pilot kit with a piezo ignitor is avai...

Страница 5: ...erformed by a qualified in staller serviceagency company orgassupplierexperiencedwith this type of gas appliance Only factory authorized components listed in these instructions may be used in accordan...

Страница 6: ...y natural gas If your gas supply is not natural gas you must install ON OFF Safety Valve Pilot Kit see Accessories page 19 Call dealer where you bought your log set If the fireplace does not have a ga...

Страница 7: ...cation The equipment shutoff valve is for turning on or shutting off gas to appliance Apply pipe joint sealant lightly to male NPT threads This will prevent excess sealant from going into pipe Excess...

Страница 8: ...for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 5 2 Pressurize supply piping system by either using compressed air or opening main gas valve...

Страница 9: ...ing optional GA9050A 1 kit go to Optional GA9050A 1 On Off Safety Valve Pilot Kit Assembly for installation instructions If using optional GA9150A kit follow instructions included with kit for install...

Страница 10: ...gas the burner inlet fitting and pilot orifice must be replaced The propane LP burner inlet fitting is supplied with orifice installed for a 24 log set If you have an 18 or 30 log set you must change...

Страница 11: ...s red for a 30 set it is black If you have a 24 log set orifice is already installed inside fitting 3 For an 18 or 30 set use a 10 mm socket or nut driver to remove orifice from pro pane LP burner inl...

Страница 12: ...e the individual tongues of flame on the burner Note The burner design includes more ports on the outside of the bar Make sure that all ports are clear and produc ing flame evenly across the burner If...

Страница 13: ...he fire department Figure 20 Placement of Top Logs Mossy Maple Logs Shown Installation Continued LIGHTING INSTRUCTIONS 1 STOP Read safety information above 2 Turn the gas shutoff valve clockwise to OF...

Страница 14: ...During the 2 3 hour appliance break in pe riod you may detect an odor from appliance as various paints and compounds used in manufacturing of this log set cure This is a normal and temporary situation...

Страница 15: ...flame to proper size see Figure 17 page 11 Do not remove adjustment screw see Troubleshooting page 16 BURNER FLAME PATTERN Burner flames will be steady not lifting or floating Flames should go up thro...

Страница 16: ...ht bends or kinks in gas supply line 1 Check for proper gas sup ply pressure 2 Free burner orifice and manifold ports of any burrs paint or other blockage 3 Verify proper burner ori fice sizing see Fi...

Страница 17: ...urn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down con trol knob Repeat igniting op eration...

Страница 18: ...lace control valve 1 Locate and correct all leaks see Checking Gas Con nections page 8 OBSERVED PROBLEM Log set produces a clicking ticking noise just after burner is lit or shut off Log set produces...

Страница 19: ...odel and serial numbers of your heater the replacement part number Accessories Purchase these log set accessories from your local dealer If they can not supply these accessories call DESA Heating Prod...

Страница 20: ...www desatech com 901746 01E 20 Parts Burner Models BVSR18 BVSR24 BVDR18 BVDR24 AND BVDR30 3 13 6 4 10 7 5 5 9 9 11 12 1 8 2...

Страница 21: ...Burner Manifold 1 901208 02 Burner Manifold 1 901209 03 Burner Manifold 1 6 901136 01 Burner Pan 1 901136 02 Burner Pan 1 901137 01 Burner Pan 1 901137 02 Burner Pan 1 901137 03 Burner Pan 1 7 901242...

Страница 22: ...ttom Rear Log CS 15 1 901111 02 Bottom Rear Log CS 20 1 901111 03 Bottom Rear Log CS 27 1 2 901711 01 Bottom Front Log VCBQ 13 1 901711 02 Bottom Front Log VCBQ 14 1 3 901710 01 Bottom Front Log VCBQ...

Страница 23: ...ttom Rear Log BPP 24 1 3 901101 01 Top Log CHR 13 1 4 901120 01 Top Log VCR 11 1 5 901121 01 Top Log VCR 12 1 6 901103 01 Top Log CHR 13Y 1 7 901115 01 Top Log VR 11 1 8 901713 01 Bottom Front Log BPP...

Страница 24: ...ack Log BFL 27 1 2 110299 01 Front Right Log 1 110302 01 Front Right Log 1 124204 01 Front Right Log BFL 30R 1 3 110298 01 Front Left Log 1 110301 01 Front Left Log 1 124203 01 Front Left Log BFL 30L...

Страница 25: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 26: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 27: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 28: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: