28
UNIVERSAL-6 60
Instructions for use
9
TECHNICAL DATA
Combustion:
Measured in compliance with
EN 13229 : 2001 and EN 13229 - A2 : 2004
Fuel
Wood
Nominal output
9 kW
Effi ciency
78%
Emissions (dry, at 13% O
2
, 273 K, 1013 hPa):
Carbon monoxide (CO)
0.09%; 1145 mg/m
3
(STP, bij 13% O
2
)
Dust
46 mg/Nm
3
(STP, at 13% O
2
)
Total hydrocarbons (C
x
H
y
)
108 mg/m
3
(STP, at 13% O
2
)
Nitrogen oxides (NO
x
)
119 mg/m
3
(STP, at 13% O
2
)
Flue gas mass fl ow
8.2 g/s
Flue temperature
291°C
Chimney draught
0.12 mbar
Flue gas connection
Ø150 mm (Ø148 mm ext.)
Weight
100 kg
Inside:
Dimensions
- surface area
0.082 m
2
- clear fi re opening (h x b)
310 x 479 mm
Interior side panels
Heat-resistant panels 1400 kg/m
3
, 1300°C
Interior bottom
Steel (heat-resistant and rust-proof)
Inner lining
Steel (heat-resistant and rust-proof)
Bottom retardant plate (brake plate)
Heat-resistant panel 2000 kg/m
3
, 1300°C
Top retardant plate
Stainless steel
Outside:
Construction
Sheet-steel casing.
Doors
Flat door opening to left.
Shutter with fi xed handle.
Operation:
• Handle for opening the door.
• Combustion air supply slider
Single combined slide for controlling the
primary, secondary and
tertiary
air supply
.
Ash collection:
Ashtray with grate.