background image

INSTRUCTIONS FOR USE & MAINTENANCE MANUAL

UNILUX-6  67 

Wood-burning 

appliance

Serial number:

Production date:

Barbas wishes you many cosy evenings with your new appliance

This document is an essential part of your appliance. 

Read it carefully before use of the appliance and keep it in a safe place! 

  

Version number:   05 - 341097

Date:   15-05-2019

Содержание UNILUX-6 67

Страница 1: ...pliance Serial number Production date Barbas wishes you many cosy evenings with your new appliance This document is an essential part of your appliance Read it carefully before use of the appliance an...

Страница 2: ......

Страница 3: ...Danny Baijens CEO Name and function Bladel September 18 2018 place and date of issue Signature The performance of the product identified in point 1 is in conformity with the declared performance in p...

Страница 4: ...4 UNILUX 6 67 Instructions for use...

Страница 5: ...ions for use CONTENTS Page 1 INTRODUCTION 7 2 SAFETY 8 3 OPERATION 10 4 USING THE APPLIANCE FOR THE FIRST TIME 11 5 USE 14 6 FUEL 21 7 MAINTENANCE 23 8 FREQUENTLY ASKED QUESTIONS 25 9 TECHNICAL DATA 2...

Страница 6: ...6 UNILUX 6 67 Instructions for use...

Страница 7: ...smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any xed boiler if located in a designated smoke control area It is also an offence to acquire an...

Страница 8: ...rous It is not allowed to connect the appliance to a ue which is already connected to another appliance Make sure you know what state your chimney is in Cracks in the chimney may not only lead to damp...

Страница 9: ...appliance to burn rubbish Do not use your appliance as a barbecue This can cause ammable fat deposits to be left in the chimney and hastens the chimney becoming clogged Ensure at all times that child...

Страница 10: ...nvection set chimney breast convection air 6 Grate 7 Ashtray 8 Inlet opening 2x grate chimney breast ventilation air chimney breast 9 Combustion air supply slider Combined operation for the primary se...

Страница 11: ...ated with a lacquer layer resistant to high temperature During the rst hours of operation the burning in of the lacquer may result in an unplea sant smell This is harmless however To speed up the proc...

Страница 12: ...eck all available functions before using the appliance for the rst time Check the opening and closing operation of the door Turn the handle all the way down Door is locked Handle forwards The door rel...

Страница 13: ...s Check the operation of the slider for the regulation of the combustion air intake middle below the window Check whether the ashtray is completely empty Report any defects immediately to your dealer...

Страница 14: ...tart the appliance the chimney is still cold and there is little draught Before the re is lit turn the operating handle completely to the right maximum air supply Open any chimney valve and the valve...

Страница 15: ...you can adjust the air supply for further combustion Make sure the appliance burns quietly Note Once you have got the appliance going leave the air supply slider in the centre position for optimal co...

Страница 16: ...there is insuf cient burning material in the rebed to light a new fuel charge excessive smoke emision can occur Refuelling must be carried out onto a suf cient quantity of glowing embers and ash that...

Страница 17: ...ls 5 5 CLEANING THE WINDOW After several burning hours a light deposit may form on the inner side of the window Once the appliance has cooled down this deposit can be removed using glass cleaner or ce...

Страница 18: ...le if the appliance is equipped with a 45 degrees chimney connection If there is too much ow resistance in the chimney causing insuf cent ow of of the ue gasses one can increase the chimney draught To...

Страница 19: ...nce spits out this is a particular problem with softwood from conifers If your oor contains ammable material an extra oor plate is required The appliance must not be operated with the air control or d...

Страница 20: ...ractor When the door is open the chimney draws in much more air than is necessary for combustion This relatively cool air cools down the appliance Excessive chimney draught The combustion air does not...

Страница 21: ...r appliance and the environment Paraf n containing open appliance lighters are not suitable for a closed appliance A closed appliance generates more heat than an open appliance thus the paraf n will m...

Страница 22: ...5 0 The heating value of wood 18 7 MJ kg at 0 humidity is not affected by the sort of wood What does make a difference is the relative humidity of the wood 15 6 MJ kg at 15 humidity Per lling for 45...

Страница 23: ...the appliance again Broken ceramic heat resistant glass may not be thrown away in a glass container but must be included in normal household waste Cleaning the appliance Wait for the appliance to cool...

Страница 24: ...appliance are not permitted House Ensure that as little dust and as few particles of cigarette smoke candles and oil lamps as possible pollute the air in the room in which the appliance is used Heatin...

Страница 25: ...lean wood in the appliance Wood that is too damp immediately gives off lots of ash Make sure the seals are in good working order Any air seeping out around the glass part of the door will cool the air...

Страница 26: ...tent of 10 The wood burns up too quickly What should I do Ensure that air cannot get in underneath the fuel Move the combustion air supply slider towards the position The primary air supply is now clo...

Страница 27: ...s The combustion of wood involves the following steps Drying The rst step is that the fuel wood dries out Even at low temperatures 100 C any moisture still in the wood will evaporate This drying proce...

Страница 28: ...ar Flue gas connection 148 mm 150 mm ext Weight 109 kg Inside Interior side panels Heat resistant panels 1400 kg m3 1300 C Interior bottom Steel heat resistant and rust proof Inner lining Steel heat r...

Страница 29: ...e the re is located or a outside air supply opening of 80 mm in wall oor Options Convection set Clean Air Act exemption The appliance has been factory tted with an air slide designed for use also in S...

Страница 30: ...s based on the applicable legal provisions Article 2 Warranty conditions 2 1 Should you wish to claim under the warranty please contact your Barbas dealer 2 2 Complaints should be reported as quickly...

Страница 31: ...parts such as glass glass cord thermocouple and the interior of the combustion chamber a similar guarantee is given until after the rst burning Article 6 Liability 6 1 A claim granted by Barbas Bell...

Страница 32: ...05 150519 341097 Your Barbas dealer...

Отзывы: