• Put a ceramic wool blanket with a thickness of at least 5 cm on the top of the

appliance and the sides and back of the appliance.

• Keep approximately 10 cm free of insulation material between the front of the

appliance and the front of the fireplace. This space is needed for the build of the
fireplace.

8.10

Build the fireplace

Caution:

• Refer to section 

5

 for clearances to flammable and non-flammable

materials.

• Refer to section 

5.1

 for applicable insulating plates.

• Make sure that brickwork is build with a clearing of at least 3 mm between

the sides and top of the appliance and the brickwork. The appliance can
expand during operation due to heating.

Note:

• Make sure the thickness of any plastering is taken into account when the

brickwork is being build.

• Do not use masking tape on the appliance. Masking tape damages the

paint on the appliance.

• If you use other material than bricks, install the material in accordance with

the instructions of the supplier of the material

• If you use other material than bricks, refer to the instructions of the supplier

of the used material for information on the need to use a mantle iron.

1.

Identify the positions where the fitting boxes of the ventilation air inlet and the
ventilation air outlet must be put. Refer to section 

6.2

 for requirements on the size of

the ventilation air openings.

2.

If the appliance has an Opti-Air system, make sure to put the room temperature
measurement cable and the battery holder in the correct position. Refer to section 

8.11

 and section 

8.12

.

3.

If applicable, identify the positions where the fitting boxes of the convection air inlets
and convection air outlets must be put. Refer to 

6.2

 for requirements on minimum

distances from ceiling and neighboring wall.

4.

Build the brickwork around the appliance up to the upper frame around the glass.
a) Install the fitting boxes of the ventilation air inlets.
b) Put the end of the NTC temperature measurement cable in the fitting box of one

of the ventilation air inlets. Make sure the ventilation air flows around the end of
the NTC temperature cable.

c)

If applicable, install the fitting boxes of the convection air inlets.

5.

If applicable, install a mantle iron to support the brickwork above the appliance. Put
the mantle iron on both sides of the brickwork. Maintain a space of at least 3 mm
between the appliance and the mantle iron.

6.

If applicable, install the flexible aluminum pipes of the convection set. Refer to
section 

8.8

.

7.

Build the fireplace around the appliance.
a) Install the fitting boxes of the ventilation air outlets.
b) If applicable, install the fitting boxes of the convection air outlets

8.

Install the frame around the appliance.

Installation in a new fireplace

Cuatro-7 75-60

39

Содержание Cuatro-7 75-60

Страница 1: ...Installation and maintenance manual Cuatro 7 75 60 Cuatro 7 75 60 Opti Air Serial number Production date...

Страница 2: ...e without the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this document...

Страница 3: ...on modes 15 3 7 Intended use 16 3 8 Installation examples 17 3 8 1 Combustion air supply from the installation room 17 3 8 2 External combustion air supply with convection set 18 4 Safety 19 4 1 Safet...

Страница 4: ...ng with adjustable height frame 33 8 5 Make the electrical connection 33 8 6 Connect the flue gas pipe 33 8 7 Connect the external combustion air supply 34 8 7 1 Connection direct on the appliance 34...

Страница 5: ...system 56 11 3 Connections on ventilator speed controller 58 12 Dimensions 59 12 1 Cuatro 7 75 60 with built in frame 59 12 2 Cuatro 7 75 60 with built in frame and convection casing 60 12 3 Cuatro 7...

Страница 6: ...1 Declaration of performance Declaration of performance 6 Cuatro 7 75 60...

Страница 7: ...w a typical setup The illustrationsare for instructional use only 2 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety section i...

Страница 8: ...appliance and the data for leak tightness as given in section 11 are not valid 3 1 Overview of the front of the appliance D H E L F B J C I G A K A Door handle B Glass C Control lever1 D Grate E Ash...

Страница 9: ...F D A E G A Heat shield steel B Lower baffle with secondary air inlet stainless steel C Upper baffle vermiculite D Air wash inlet E Connector for the combustion air inlet pipe F Convection air inlet...

Страница 10: ...3 3 Overview of combustion air inlet box D A C B D A Combustion air inlet box B Combustion air inlet C Adjustable height frame option D Adjustable feet Description 10 Cuatro 7 75 60...

Страница 11: ...the convection ventilator combustion air inlet box E C B D F A C A Convection ventilator combustion air inlet box B Combustion air inlet C Convection air inlet D Convection ventilator Description Cua...

Страница 12: ...ings are optionally on the front of the appliance and or via outlet openings in the chimney breast 30 flue connector Not available in combination with a convection system Adjustable height frames The...

Страница 13: ...the room temperature If the actual room temperature is higher than the set room temperature a relative long time is necessary to reach the set room temperature With the Barbas Opti Air system it is n...

Страница 14: ...ge temperature unit C or F Notifications Select the type of notifications Note The notification door open is out of order Homescreen Setup Change the name of the appliance Select which parameters are...

Страница 15: ...ugh 5 different combustion modes each with its own pre programmed combustion characteristics During the combustion process one of these combustion modes is active dependent on the temperature in the c...

Страница 16: ...uels The appliance is intended for use with the door closed The appliance may only be used at the location that meets the requirements for the installation of the appliance The appliance is intended f...

Страница 17: ...3 8 1 Combustion air supply from the installation room F B A E D C A Combustion air inlet B Ventilation air inlet C Chimney D Ventilation air outlet E Insulating material F Air supply to the room Desc...

Страница 18: ...ction set G D F I C E A B A Combustion air inlet B Convection air inlet opening C Ventilation air inlet opening D Chimney E Insulating material F Convection air outlet G Ventilation air outlet I Flexi...

Страница 19: ...masking tape on the appliance Masking tape can damage the finish of the appliance Do not use fiberglass rockwool or any other sort of insulation material These materials produce a pungent odor and can...

Страница 20: ...Skamol Skamotec 225 0 06 W m K Skamol Super Isol 0 08 W m K Only use white unbound ceramic insulation wool Do not use glass wool or rock wool these materials can cause a bad smell unwanted smoke and...

Страница 21: ...le insulation plate with a minimum thickness of 3 cm under the appliance To avoid damage to this non flammable plate put ceramic or steel tiles approx 10 x 10 cm under the feet of the appliance 5 4 Cl...

Страница 22: ...ed in the tabel hereunder h H 3 5 1 2 4 A 1 Chimney enclosure 2 Convection air outlet opening 3 Flammable ceiling 4 Insulation plate false ceiling 5 Insulation plates With false ceiling Without false...

Страница 23: ...iance and the rear wall and side wall according the figure hereunder Obey the requirements as mentioned in the table hereunder D A E A B C C B B 2 F 1 1 E F 3 1 Non flammable spacer 2 Non flammable in...

Страница 24: ...tabel hereunder A h H 3 5 4 1 2 B 1 Chimney enclosure 2 Convection air outlet opening 3 Non Flammable ceiling 4 Insulation plate false ceiling 5 Insulation plates Dimensions h Area of the convection a...

Страница 25: ...mum depth is dependent on the installation height of the appliance C Minimum 180 cm clearance from the front of the appliance Put a non flammable floor plate with a minimum thickness of 12 mm in front...

Страница 26: ...The non flammable floor plate must have a width that extends minimum 150 mm from each side of the appliance Clearances 26 Cuatro 7 75 60...

Страница 27: ...concrete or a solid pedestal of nonflammable material Make sure that the floor temperatures under and in front of the appliance are maximum 85 C during use of the appliance Refer to section 5 3 and s...

Страница 28: ...flexible or rigid chimney in any new or existing masonry chimney Make sure to insulate the stainless steel chimney or use double walled insulated stainless steel chimney elements Make sure the flue sy...

Страница 29: ...t with a hose clamp 7 Put a layer of ceramic wool around the flexible flue pipe 8 Remove the interior of the appliance Refer to section 10 5 for instructions 9 Remove the screws that hold the flue pip...

Страница 30: ...on 10 5 for instructions 7 4 Aligning with adjustable feet 1 Adjust the adjustable feet Use a 13 mm fork spanner 2 Align the appliance horizontal Use a spirit level 7 5 Final check on the appliance 1...

Страница 31: ...ation Warning The electrical connections must be made by a certified electrician The optional convection ventilator and optional Opti Air system both need a 230 VAC electrical power supply near the in...

Страница 32: ...inimum 3 Make sure there is minimum 3 mm gap between the bottom of the air box and the floor 4 Remove the carrying tubes 5 Make sure the door opens and closes correctly 6 Refer to section 5 2 for meas...

Страница 33: ...an be connected to steel pipes double walled insulated stainless steel flues and flexible stainless steel flues with an outside diameter of 180 mm Preliminary requirements If the appliance is installe...

Страница 34: ...stion air inlet on the combustion air box the combustion air inlet on the convection ventilator combustion air box If not connected to one of these three possibilities the appliance is not a room seal...

Страница 35: ...the 3 inlet openings on the left right or bottom of the optional combustion air inlet box or the convection ventilator combustion air inlet box 5 Remove the break out plate in the selected inlet open...

Страница 36: ...adaptor 2 and turn the adapter until it locks 5 Connect a flexible aluminum pipe C on the collar adaptor Use a hose clamp B 6 Connect the flexible aluminum pipe to a fitting box in the chimney breast...

Страница 37: ...on top of the appliance Refer to section 8 8 2 To not obey this can cause damage to the appliance Note A convection ventilator causes a strong air flow from the front outlet openings To reduce this fl...

Страница 38: ...llar adaptor and turn the collar adaptor until it locks 4 Connect the flexible aluminum pipes C on the collar adaptors Use a hose clamp B 5 Connect the flexible aluminum pipes to fitting boxes in the...

Страница 39: ...section 6 2 for requirements on the size of the ventilation air openings 2 If the appliance has an Opti Air system make sure to put the room temperature measurement cable and the battery holder in th...

Страница 40: ...2 Make sure the battery holder is accessible through the inlet opening of the ventilation air 8 13 Final check on the appliance Caution Wait 4 weeks after the installation before you use the appliance...

Страница 41: ...e a connection with bluetooth with device Airmaster 5 When asked enter the PIN code 000000 6 The app is now ready for use Note It is possible to install the Barbas Opti Air app on multiple mobile devi...

Страница 42: ...ris 2 Clean the inlet of the pipe of the external combustion air supply 10 3 Convection air system Preliminary requirements Do the procedure in this section only when a convection air system has been...

Страница 43: ...s Refer to section 10 5 5 6 Remove the steel bottom plates Refer to section 10 5 6 7 Remove the cast iron side panels Refer to section 10 5 7 8 Remove the vermiculite panels Refer to section 10 5 8 10...

Страница 44: ...the upper baffle Only do this procdure after finish of the procedure in section 10 5 2 1 Push up the right side of the upper baffle a small distance 1 2 Lower the left side of the upper baffle a smal...

Страница 45: ...ree panels are hooked into each other The fourth panel is the fitting piece The location of this panel is on the left side or the right side 1 Identify the fitting piece The fitting piece is the most...

Страница 46: ...n 10 5 5 1 Move the 2 steel bottom plates a small distance to the center of the fireplace bottom 2 Lift the steel bottom plates up and remove 10 5 7 Remove the cast iron side panels Only do this proce...

Страница 47: ...on 10 6 2 3 Install the steel bottom plates Refer to section 10 6 3 4 Install the cast iron rear panels Refer to section 10 6 4 5 Install the grate Refer to section 10 6 5 6 Install the upper baffle R...

Страница 48: ...tom plates Only do this procedure after finish of the procedure in section 10 6 2 1 Put a steel bottom plate on the bottom of the combustion chamber 2 Move the steel bottom plate to the left as much a...

Страница 49: ...r wall Move the bottom plate to the center to let you install the fitting piece 10 6 5 Install the grate Only do this procedure after finish of the procedure in section 10 6 4 1 Put a grate on the ash...

Страница 50: ...l the upper baffle Only do this procdure after finish of the procedure in section 10 6 5 1 Move the upper baffle under an angle into the combustion chamber 2 Move the left side of the baffle as high a...

Страница 51: ...under an angle into the combustion chamber 1 3 Move the baffle up under an angle and put the right side of the baffle above the cast iron side panels 2 4 Put the rear side of the baffle against the re...

Страница 52: ...correct position and install the lower baffle again 10 6 8 Install the heat shield Only do this procedure after finish of the procedure in section 10 6 7 1 Move the heat shield up and put the rear sid...

Страница 53: ...Opti Air system 1 Remove the ventilation air inlet grate 2 Get the battery holder Put a screwdriver in the small notch of the lid and pull out the battery 3 Replace the 9 V battery and close the batte...

Страница 54: ...direct heating function No Leak rate at 10 Pa 1 6 m3 h at 273 K 1013 hPa Emissions at 13 O2 273 K 1013 hPa carbon monoxide CO 0 12 vol 1500 mg Nm3 particles PM 30 mg Nm3 organic gaseous compounds OGC...

Страница 55: ...able options Convection ventilator combustion air inlet box Convection casing Combustion air inlet box Set of 2 adjustable height frames Opti Air combustion control Battery Opti Air system 9 V block P...

Страница 56: ...11 2 Connections on Opti Air system Technical data 56 Cuatro 7 75 60...

Страница 57: ...e black wire Battery 9V battery back up The 9V battery back up makes sure the air valves go to a safe position when there is an electric power interruption brown wire blue wire 0 10 VDC output Control...

Страница 58: ...or speed controller B C A A 230 VAC input to ventilator speed controller B 0 230 VAC variable output to ventilator C 0 10 VDC variable control signal from Opti Air system to ventilator controller Tech...

Страница 59: ...12 Dimensions 12 1 Cuatro 7 75 60 with built in frame Dimensions Cuatro 7 75 60 59...

Страница 60: ...12 2 Cuatro 7 75 60 with built in frame and convection casing Dimensions 60 Cuatro 7 75 60...

Страница 61: ...12 3 Cuatro 7 75 60 with built in frame and external air connection Combustion air inlet opening 125 mm at the bottom of the appliance Dimensions Cuatro 7 75 60 61...

Страница 62: ...12 4 Cuatro 7 75 60 with built in frame external air connection and convection casing Combustion air inlet opening 125 mm at the bottom of the appliance Dimensions 62 Cuatro 7 75 60...

Страница 63: ...12 5 Cuatro 7 75 60 with built in frame and air box 3 Combustion air inlet openings 125 mm at the left side right side and bottom of the air box Dimensions Cuatro 7 75 60 63...

Страница 64: ...vection casing 3 Combustion air inlet openings 125 mm at the left side right side and bottom of the air box 2 Convection air inlet openings 125 mm at the left side and right side of the convection ven...

Страница 65: ...ir inlet openings 125 mm at the left side right side and bottom of the air box 2 Convection air inlet openings 125 mm at the left side and right side of the convection ventilator combustion air box An...

Страница 66: ...12 8 Cuatro 7 75 60 with classic frame Dimensions 66 Cuatro 7 75 60...

Страница 67: ...12 9 Cuatro 7 75 60 with classic frame and convection casing Dimensions Cuatro 7 75 60 67...

Страница 68: ...12 10 Cuatro 7 75 60 with classic frame and external air connection Combustion air inlet opening 125 mm at the bottom of the appliance Dimensions 68 Cuatro 7 75 60...

Страница 69: ...12 11 Cuatro 7 75 60 with classic frame external air connection and convection casing Combustion air inlet opening 125 mm at the bottom of the appliance Dimensions Cuatro 7 75 60 69...

Страница 70: ...12 12 Cuatro 7 75 60 with classic frame and air box 3 Combustion air inlet openings 125 mm at the left side right side and bottom of the air box Dimensions 70 Cuatro 7 75 60...

Страница 71: ...vection casing 3 Combustion air inlet openings 125 mm at the left side right side and bottom of the air box 2 Convection air inlet openings 125 mm at the left side and right side of the convection ven...

Страница 72: ...ir inlet openings 125 mm at the left side right side and bottom of the air box 2 Convection air inlet openings 125 mm at the left side and right side of the convection ventilator combustion air box An...

Страница 73: ...hts and claims based on the applicable legal provisions Article 2 Warranty conditions 1 Should you wish to claim under the warranty please contact your Barbas dealer 2 Complaints should be reported as...

Страница 74: ...n chamber a similar guarantee is given until after the first burning Article 6 Liability 1 A claim granted by Barbas Bellfires B V under this warranty does not automatically imply that Barbas Bellfire...

Страница 75: ...Warranty Terms Cuatro 7 75 60 75...

Страница 76: ...Your Barbas dealer 001 28 06 2022 352574 271 001...

Отзывы: