11
er straight up and out of the grinder
housing. The ceramic or steel burr
are mounted to the underside of
the burr carrier. Clean the burrs
using a stiff brush.
Do not
wash
the burrs with water.
Replacing the Upper Burr
With your hand, gently thread the
upper burr carrier turning
counter
-clockwise
until finger tight . Us-
ing the Baratza Burr Tool, rotate
the burr carrier counter-clockwise
an additional 1/8 inch or 2 mm. (do
not over tighten).
Replacing the Bean Hopper
To replace the bean hopper line
up the two small tabs on the base
of the hopper with their respec-
tive slots in the top of the grinder
housing and insert the hopper into
the grinder. Once the hopper is
in place rotate it clockwise until it
clicks to a stop (about ¼ inch or 4
cm).
Automatic Cleaning
A thorough, fast, and easy clean-
ing can be accomplished using Full
Circle
™
, biodegradable, grinder
cleaning tablets. Full Circle
™
tab-
lets are designed to dislodge cof-
fee particles and absorb and re-
move odors and coffee oil residue.
Simply place the recommended
amount into the empty grinder
hopper. Adjust the grind setting to
Coarse, place the grounds bin on
the load cell and press WEIGHT,
M (manual) then the START but-
ton. Grind all of the tablets into
the bin, then press STOP. Once
complete we recommend grinding
some coffee (4 tbs.) to remove any
tablet residue. Discard the ground
coffee. For information on Full Cir-
cle
™
cleaning tablets go to www.
urnex.com. or baratza.com.