Baracoda RoadRunners Laser Скачать руководство пользователя страница 14

                 

RoadRunners Linear CMOS Programming guide (Oct. 05) 

© Baracoda 2005  

13/24 

2.5

 

Code 11 Settings 

 

Code 11 - not active (*) 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T J D \ S O H B \ F F \ F F

Di s abl e CODE11

 

 

Code 11 - active 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T J D \ S O H A \ F F \ F F

Enabl e CODE11

 

 
Code 11 - check digits - 1 digit (*) 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T J D \ S O H F \ F F \ F F

 

 

Code 11 - check digits - 2 digits 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T J D \ S O H E \ F F \ F F

 

 

 
 

 

 

 

 

Code 11 - check digits - checked and transmitted (*) 

 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T J D \ S O H G \ F F \ F F

 

 

Code 11 - check digits - checked but not transmitted 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T J D \ S O H H \ F F \ F F

 

 

Code 11 - barcode length - any length  

\ V T \ V T \ F N C 4 ~ \ N U L \ E N Q J D \ S T X C d \ F F \ F F

CODE11any l engt h

 

 

Code 11 – barcode length – Min = 6 (*) 

\ V T \ V T \ F N C 4 ~ \ N U L \ E N Q J E \ S T X A \ A C K \ F F \ F F

CODE11 Mi n l engt h = 6

2.6

 

Code 39 settings 

 

Code 39 - active (*) 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T E D \ S O H A \ F F \ F F

Enabl e CODE39

 

 

Code 39 - not active 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T E D \ S O H B \ F F \ F F

Di s abl e CODE39

 

 

 

Code 39 - format - standard 43 characters (*) 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T E D \ S O H O \ F F \ F F

 

 

 

Code 39 - format - full ASCII 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T E D \ S O H N \ F F \ F F

 

 
 

Code 39 - start/stop - not transmitted (*) 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T E D \ S O H J \ F F \ F F

 

 

 
Code 39 - start/stop - transmitted 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T E D \ S O H I \ F F \ F F

 

 

 

Code 39 - start/stop - accepted characters - * only 

(standard Code 39) (*) 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T E D \ S O H K \ F F \ F F

 

 

Code 39 - start/stop - accepted characters - $ only 

(Trioptic Code 39) 

\ V T \ V T \ F N C 4 ~ \ N U L \ E O T E D \ S O H L \ F F \ F F

 

 

Содержание RoadRunners Laser

Страница 1: ...ever we accept no responsability for errors or omissions including but not limited to the implied warranties of merchantability and tness for a particular purpose We shall not be liable for errors con...

Страница 2: ...X 1 ASCII Table A Z a z 0 9 ponctuation Control characters 20 APPENDIX 2 24 INTRODUCTION Please verify that your Roadrunners has a firmware version equal or superior to 2 5 before using it with this p...

Страница 3: ...Real Time with No Data Loss Mode ON By reading the following barcode you will empty the internal memory of the scanner Empty memory V T V T F N C 4 N U L N U L F F F F er ase st or ed bar codes 1 3 Ba...

Страница 4: ...in and again This acknowledgment is disabled in default settings It is strongly recommended to set this protocol acknowledgment on when using the scanner with the BaracodaManager Enables Baracoda head...

Страница 5: ...els Appendix 1 as on a calculator following the timestamp format shown above For example to set the current time at 16th May 2007 3 25 pm the user will scan Set Timestamp label 0 label 7 label 0 label...

Страница 6: ...on the decoder thus allowing user to aim at the correct barcode while pressing the trigger the second time will activate the decoder thus allowing the RoadRunners to actually decode the barcode In au...

Страница 7: ...and bufferisation Forces the RoadRunners in Real Time mode with data acknowledgement Erases all codes in memory The BRR should have been previously set in the No data loss mode ON V T V T d N U L S O...

Страница 8: ...ou can use this option to enable or disable the buzzer and or the Led You can also invert the led position LED CONFIG default V T V T F N C 4 S O N U L S O H N U L F F F F l eds def aul t LED CONFIG i...

Страница 9: ...U L E N Q H T N U L F N C 4 E T X F F F F sni f f per i od 500m s Sniff period 300ms V T V T NUL E NQ HT NUL F NC4 SOH F NC4 a F F F F Set sni f f per i od 300m s 1 7 2 Power emission settings You can...

Страница 10: ...pr ef i x of f SUFFIX on V T V T F N C 4 h N U L S O H F N C 4 A F F F F suf f i x on SUFFIX off V T V T F N C 4 h N U L S O H F N C 4 F F F F suf f i x of f max length of the Suffix Prefix is 32 cha...

Страница 11: ...RoadRunners Linear CMOS Programming guide Oct 05 Baracoda 2005 10 24 L F L F E N D F F F F END of Conf i g...

Страница 12: ...tted V T V T F N C 4 v N U L S O H N U L F F F F Di sabl e AI M Sym bol of y I dent i f i er Tr ansm i ssi on Symbology identifier AIM transmitted V T V T F N C 4 v N U L S O H S O H F F F F Enabl e A...

Страница 13: ...op not transmitted V T V T F N C 4 N U L E O T F D S O H J F F F F Codabar start stop transmitted V T V T F N C 4 N U L E O T F D S O H I F F F F CODABAR s s t r ansm i t t ed Codabar check digit AIM...

Страница 14: ...T X C d F F F F CODE11any l engt h Code 11 barcode length Min 6 V T V T F N C 4 N U L E N Q J E S T X A A C K F F F F CODE11 M i n l engt h 6 2 6 Code 39 settings Code 39 active V T V T F N C 4 N U L...

Страница 15: ...T V T F N C 4 N U L E N Q E E S T X A A C K F F F F CODE39 M i n l engt h 6 2 7 Code 93 Settings Code 93 not active V T V T F N C 4 N U L E O T B D S O H B F F F F Di sabl e CODE93 Code 93 active V T...

Страница 16: ...not t r ansm i t t ed Interleaved 2 of 5 barcode length minimum length 6 V T V T F N C 4 N U L E N Q G E S T X A A C K F F F F I nt er l eaved 2of 5 M i n l engt h 6 Interleaved 2 of 5 barcode length...

Страница 17: ...cked and transmitted V T V T F N C 4 N U L E N Q H D S T X E G F F F F STD25 check di gi t checked and t r ansm i t t ed Standard 2 of 5 check digit mod 10 checked but not transmitted V T V T F N C 4...

Страница 18: ...sm i ssi on UPC EAN check digit EAN 8 not transmitted V T V T F N C 4 N U L E O T M D S O H H F F F F Di sabl e EAN8 check di gi t t r ansm i ssi on UPC EAN UPC number system UPC A transmitted V T V T...

Страница 19: ...oding UPC A UPC E EAN 8 EAN 8 transmitted as EAN 13 V T V T F N C 4 N U L E O T M D S O H X F F F F Tr ansm i t EAN8 as EAN13 2 13 Set min or Max length option The following is a procedure to follow f...

Страница 20: ...E L F L F Code 39 L F L F F L F L F Codabar L F L F G L F L F Interleaved 2 of 5 L F L F H L F L F Standard 2 of 5 industrial 2 of 5 L F L F J L F L F Code 11 L F L F K L F L F MSI L F L F L L F L F...

Страница 21: ...O L F L F O L F L F C L F L F C L F L F P L F L F P L F L F D L F L F D L F L F Q L F L F Q L F L F E L F L F E L F L F R L F L F R L F L F F L F L F F L F L F S L F L F S L F L F G L F L F G L F L F...

Страница 22: ...L F r L F L F r L F L F f L F L F f L F L F s L F L F s L F L F g L F L F g L F L F t L F L F t L F L F h L F L F h L F L F u L F L F u L F L F i L F L F i L F L F v L F L F v L F L F j L F L F j L F...

Страница 23: ...L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F _ L F L F _ L F L F _ L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F t i l de Decimal numb...

Страница 24: ...Characters Name Programming label CR L F L F C R L F L F CR EOT L F L F E O T L F L F EOT ETX L F L F E T X L F L F ETX LF L F L F L F L F L F LF NUL L F L F N U L L F L F NUL SOH L F L F S O H L F L...

Страница 25: ...racter is determined by summing the option values of each symbology If the sum is greater than 9 use A B C D E F in the place of 10 11 12 13 14 and 15 Code 39 Option Values 0 No check character or Ful...

Отзывы: