background image

 

RoadRunners Evolution – Communication Protocol v1.5 

  - 44 - 

Data Capture 

for Workforce 

in Motion 

Payload 

 

Response 

0x39 00 02 [UUID] 

Remark 

Try to connect to this remote service. 

 

Here are some service UUID: 

SPP 

0x1101 

DUN 

0x1103 

FAX 

0x1102 

You can get more UUIDs by reading the Bluetooth spec. 

 

Command 

Get Encryption Mode 

Header 

0x40 

Length 

00 00 

Payload 

 

Response 

0x40 00 01 [encryption] 

Remark 

 

 

Command 

Set Encryption Mode 

Header 

0x41 ( flash only) 

Length 

00 01 

Payload 

[Encryption (1 byte)] 

Response 

0x41 00 01 01 if done 

0x41 00 01 00 if not 

Remark 

Argument is: 0x01 to enable encryption, 0x00 to disable. 

 

Command 

Get local Bluetooth Address 

Header 

0x43 

Length 

00 00 

Payload 

 

Response 

0x43 00 06 {6 Bytes (BD_address MSB, ..., LSB)} 

Remark 

 

 

 

 

 

 

 

 

 

Содержание RoadRunner BRR-FS

Страница 1: ...Data Capture for Workforce in Motion RoadRunners Evolution Communication Protocol Baracoda TM January 2009...

Страница 2: ...2 3 1 COMMUNICATION MESSAGES 7 2 3 2 SCANNER MESSAGES 10 2 3 3 USER INTERFACE MESSAGES 13 2 3 4 MISCELLANEOUS MESSAGES 16 2 3 5 CAPTURE MESSAGES 20 2 4 DECODER COMMUNICATION PROTOCOL 23 2 4 1 FRAME FO...

Страница 3: ...Date Description 1 0 02 July 08 Initial release 1 2 03 July 08 Presentation updated 1 3 11 July 08 Data string format section updated 2 2 1 1 4 29 Sept 08 Added new commands 0x5A 0x5B Get Set master...

Страница 4: ...is document can be Host to scanner messages the packet is sent only by the host to the scanner Scanner to host messages the packet is sent only by the scanner to the host Bidirectional messages the pa...

Страница 5: ...2 1 1 2 Acknowledgment packets Code ID Description Frame 0x06 ACK 0x06 0x01 0xYY 0x15 NACK 0x15 0x01 0xYY These messages acknowledge the reception of a valid message with the expected sequence number...

Страница 6: ...messages messages messages messages 2 2 1 Encapsulation scheme Code ID Description Payload 0x32 0x33 Barcode data DATA string 2 2 2 Data string format Timestamp Data Prefix Capture Prefix Symbology P...

Страница 7: ...mission Parameters Payload None Response 2 bytes Max number of retransmission 1 to 0xFE 0xFF infinity Delay between transmission 1 to 0xFF in tenth of seconds Code ID 0x44 0x45 Description Set Retrans...

Страница 8: ...yte Bit 0 Success Code ID 0x54 0x55 Description Get Set dock use Payload Get None Set 1 byte 0 Disable communication via RS232 dock 1 Enable Response Get 1 byte 0 Disable communication via RS232 dock...

Страница 9: ...isable OPTIONAL 1 disconnect the scanner if connected Response Get 1 byte 1 enabled 0 disabled Set 1 byte Bit 0 Success Code ID 0x5E 0x5F Description Bluetooth Commands Payload Code ID Parameters Resp...

Страница 10: ...escription Set Operating Mode Payload 1 byte Bit 0 0 real time Bit 0 1 batch If real time mode is set Bit 7 limited Bit 6 ACK beep Bit 5 no ACK beep NOTE the ACK beep enable disable is only effective...

Страница 11: ...ters Payload Get None Set 1 3 or 5 bytes Mode min len recepisse max len recepisse min len statut max len statut Response Get 5 bytes Mode min len recepisse max len recepisse min len statut max len sta...

Страница 12: ...Workforce in Motion Code ID 0x78 0x79 Description Get Switching On Delay Payload None Response 1 byte 1 0 second 2 1 second 3 2 seconds Code ID 0x7A 0x7B Description Set Switching On Delay Payload 1...

Страница 13: ...0 LEDs enabled Code ID 0x84 0x85 Description Set MMI Mode Payload 1 byte Bit 1 Buzzer Enabled Bit 0 LEDs enabled Bit 7 0 Buzzer config select 1 Buzzer config deselect Bit 6 0 leds config select 1 led...

Страница 14: ...2 bytes Signal number 0 3 Number of loops 0 0xFE 0xFF infinity Response 1 byte Bit 0 Success Code ID 0x8C 0x8D Description Stop Signal Payload 1 byte Signal number 0 3 Response 1 byte Bit 0 Success Th...

Страница 15: ...15 Data Capture for Workforce in Motion Bit 7 0 ACK beep config select 1 ACK beep config deselect Bit 6 0 Read beep config select 1 Read beep config deselect Bit 5 0 Beep level config select 1 Beep le...

Страница 16: ...Set DataSuffix Payload Get None Set 1 33 bytes DataSuffix length DataSuffix String Response Get 1 33 bytes DataSuffix length DataSuffix String Set 1 byte Success Code ID 0xC6 0xC7 Description Get Set...

Страница 17: ...scanner 1byte 0 restore defaults keep link keys reboot scanner 1 switch off scanner no restoring defaults 2 reboot scanner no restoring defaults Response 1 byte Bit 0 Success Code ID 0xCE 0xCF Descrip...

Страница 18: ...Bit 0 Success Code ID 0xD2 0xD3 Description Get Set Anti duplicate scans Payload Get None Set 1 byte 0 disabled 1 no consecutive duplicate scans error signal 2 no consecutive duplicate scans no decodi...

Страница 19: ...Evolution Communication Protocol v1 5 19 Data Capture for Workforce in Motion Code ID 0xD8 0xD9 Description Enable remote trigger Payload None use default 5s timeout 1 byte timeout s Response 1 byte B...

Страница 20: ...n 4 aiming trigger scan Code ID 0xE4 0xE5 Description Set Mode Payload 1 byte OR 2 bytes if aiming trigger scan mode 0 trigger 1 smart autoscan 2 disabled 3 autoscan 4 aiming trigger scan aiming trigg...

Страница 21: ...1 byte Bit 0 Success Code ID 0xEE 0xEF Description Get Capture Suffix Payload None Response 1 33 bytes Capture Suffix length Capture Suffix String Code ID 0xF0 0xF1 Description Set Capture Suffix Pay...

Страница 22: ...ount 7 0 Code ID 0xFC 0xFD Description Erase stored barcodes Payload None Response 1 byte Bit 0 Success Code ID 0xFE 0xFF Description Barcode decoder Commands Payload header type size Parameters Respo...

Страница 23: ...r field defines the type of symbology to select it is 1 byte long ACSII code Header Selected Symbology A SELECT ALL B Code 93 C Code 128 EAN 128 D EAN 13 UPC A E Code 39 F Codabar G Interleaved 2 of 5...

Страница 24: ...ter s to use More details will be given in the section Command field All the commands will answer 0 if the frame is wrong Commands with type B C D or E will answer 1 as an acknowledgment of good recep...

Страница 25: ...ommand the default minimal length will be 6 characters for all symbologies 2 This option will not have any effect on symbologies that require a checksum EAN UPC code93 Code128 RSS Concerning the symbo...

Страница 26: ...2 ISSN hyphen transmission 3 ISSN price code transmission 4 UPC A transmitted as EAN 13 5 Add on Digits required not required 6 Enable disable Add on 2 MSB 7 Enable disable Add on 5 CODE 39 Header E...

Страница 27: ...FREE 2 FREE 3 FREE 4 FREE 5 FREE 6 FREE MSB 7 FREE STANDARD 2 OF 5 Header H Bit Option LSB 0 FREE 1 FREE 2 FREE 3 FREE 4 FREE 5 FREE 6 FREE MSB 7 FREE MATRIX 2 OF 5 Header I Bit Option LSB 0 FREE 1 F...

Страница 28: ...FREE 5 FREE 6 FREE MSB 7 FREE UPC E Header L Bit Option LSB 0 Number System transmitted 1 2 3 4 FREE 5 UPC E transmitted as UPC A 6 MSB 7 FREE EAN 8 Header M Bit Option LSB 0 FREE 1 2 3 4 EAN 8 trans...

Страница 29: ...3 2 4 5 3 2 4 5 3 Usual Usual Usual Usual Commands Commands Commands Commands Type Type Type Type D D D D The method described above set config allows a fast and effective setting of a whole set of co...

Страница 30: ...e E O Disable Code 39 full ASCII mode E P Enable number system transmission D L Q Disable number system transmission D L R Disable prefix All S Enable prefix All T Disable suffix All U Enable suffix A...

Страница 31: ...mands Commands Commands Commands Type Type Type Type E E E E Some commands require more than a Boolean digit and require one or more arguments Special commands will be used in this case defined code E...

Страница 32: ...answers the following frame E A 4 01 05 06 20 Header Type Size Command By reading this answer frame we can check that the decoder has well understood the selected symbology header E The command field...

Страница 33: ...the decoder understands The user wants to set a configuration Type B for Codabar Header F the configuration will contain general options and others specific to cadabar Size 2 Then the Command field c...

Страница 34: ...ed 1 4 Max length Enabled set to 32 as default 0 5 0 6 0 7 2 4 6 3 2 4 6 3 2 4 6 3 2 4 6 3 Usual command Usual command Usual command Usual command Example 3 1 Modifying a configuration of all symbolog...

Страница 35: ...40 Header Type Size Command Reading this frame the decoder understands The user wants to send a special command Type E to Code39 symbology Header E The size must be at least 2 and the first byte of th...

Страница 36: ...h only Length xx xx new pin size Payload N digits PIN Defaut 0000 Response 0x01 00 01 01 if done 0x01 00 01 00 if not Remark Max Pin length 16 Command Get Pin Code Header 0x07 Length 00 00 Payload N d...

Страница 37: ...ock If more than one SmartModule needs to connect to the same other device PC Access Point you will need to switch the clock role to allow the slave to be connected to more than one master Note that m...

Страница 38: ...0 04 Inquiry Interval MSB Inquiry Interval LSB Inquiry Window MSB Inquiry Window LSB Remark Inquiry Interval and Inquiry Window are in number of Bluetooth slots 1 slot 0 625 ms Command Set inquiry sca...

Страница 39: ...ot be Connectable Command Get page scan timeout Header 0x25 Length 00 00 Payload Response 0x25 00 04 Page Interval MSB Page Interval LSB Page Window MSB Page Window LSB Remark Page Scan Interval and P...

Страница 40: ...and Get Sniff Header 0x10 Length 00 00 Payload Response 0x10 00 08 MSB of MinSniff interval LSB of MinSniff interval MSB of MaxSniff interval LSB of MaxSnif interval Sniff Attempts MSB Sniff attempts...

Страница 41: ...o 0xFF means a sniff period of 40s You will have very very low data rate Note This setting takes effect immediately For further details on Sniff values see the Bluetooth spec 1 1 chapter 10 8 2 Comman...

Страница 42: ...01 secured PIN CODE default 01 Response 0x21 00 01 01 if done 0x21 00 01 00 if not Remark Size PINCODE size 1 For example 0x21 00 05 00 30 30 30 30 to disable security Command Get Bluetooth class dev...

Страница 43: ...ader 0x37 Length 00 00 Payload Response 0x37 00 01 channel Remark If channel is not zero the Module will directly try to connect if in master mode to the specified rfcomm channel Setting the channel t...

Страница 44: ...reading the Bluetooth spec Command Get Encryption Mode Header 0x40 Length 00 00 Payload Response 0x40 00 01 encryption Remark Command Set Encryption Mode Header 0x41 flash only Length 00 01 Payload E...