No Check Character indicates that the imager reads and transmits bar code data with or without a
check character.
When Check Character is set to Validate and Transmit, the imager will only read Codabar bar codes
printed with a check character, and will transmit this character at the end of the scanned data.
When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar
codes printed with a check character, but will not transmit the check character with the scanned
data.
Validate Modulo 16
and Transmit
3.4.3
Codabar Concatenation
Codabar supports symbol concatenation. When you enable concatenation, the imager looks for a
Codabar symbol having a
“
D
”
start character, adjacent to a symbol having a
“
D
”
stop character. In
this case the two messages are concatenated into one with the
“
D
”
characters omitted. Default =
On.
Character start
Select Require to prevent the imager from decoding a single
“
D
”
Codabar symbol without its
companion. This selection has no effect on Codabar symbols without Stop/Start D characters.
3.4.4
Codabar Message Length
Scan the bar codes below to change the message length. Refer to Message Length Description
(chapt 3.2) for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4,
15
* On
Off
Require