background image

                                                              BC/BL/BLR2604 Programming Guide 

 

4

 

General configuration 

 

Start of Configuration 

 

 

 
 

4.1

 

Scanning mode selection 

 

The scanner becomes inactive as soon as the data is 
transmitted.  It must be triggered to become active 
again. 
 
 
In auto scan mode, the scanner is still active after the 
data is transmitted, but the successive transmission of 
the same bar code is not allowed when the trigger 
switch is pressed again.

 

 

Trigger mode 

 

Auto scan mode 

 
 

4.2

 

Good read beeper tone selection 

You can use this option to set frequency and / or duration of the buzzer after successful reading. 

 
 
 

 

Low 

 

Medium 

 
 

 

High 

 

Disable 

 

4.3

 

Sound duration 

 

 
 

 

long(120 ms) 

 

Medium(50 ms) 

 
 

 

Short(20 ms) 

 

Very short(5 ms) 

 

 

 

 

 

 

 

 

End of Configuration

 

© Baracoda 2004 

 Page 6/22 

Содержание BC2604

Страница 1: ...y of our product information however we accept no responsability for errors or omissions including but not limited to the implied warranties of merchantability and fitness for a particular purpose We shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing performance or use of this material Specifications or version may be subject to ...

Страница 2: ...to change without notice The actual specification and version are based on the product delivered INTRODUCTION Scanning a series of programming bar code labels can configure the scanner The scanner must be properly powered before programming During the programming mode the scanner will acknowledge a good and valid reading with a short beep It will give long beeps for either an invalid or bad readin...

Страница 3: ...Code 9 parameters setting 9 IInterleaved 2 of 5 parameters setting 9 Chinese post code parameters setting 10 Codabar Monarch parameters setting 10 UPC EAN JAN parameters setting 11 UPC EAN JAN parameters settings Cont d 13 Code 128 parameters setting 13 UCC EAN128 parameters setting 13 Industry 25 parameters setting 14 Msi Plessy setting 14 Italian pharmacy parameters setting 15 Barcode length set...

Страница 4: ...e L MSI Barcode Identifier Code P Industry 2 of 5 Identifier Code R IATA Identifier Code T 1 3 Default values of decoding parameters Function Code Default Value Code 39 Enable ITF 2 of 5 Enable Chinese Post Code Disable UPC EAN JAN Enable Codabar Enable MSI PLESSY Disable Code 128 Enable Code 93 Enable ITAT Disable EAN 128 Disable Industry 2 of 5 Disable Italian Pharmacy Disable Reading codes Sele...

Страница 5: ...e Baracoda 2004 Page 4 22 2 Program procedure using barcode menus Read Start of configuration Label SET ALL DEFAULTS SET GENERAL CONFIGURATION SET SYMBOLOGIES SET DATA EDITING FINISH Read End of configuration Label YES NO END START ...

Страница 6: ...ngs The reading of the Default settings label turns all the parameters back to default settings When you intend to turn your scanner back to default parameter please scans the Start of configuration label first then scan Default settings label and finally scan the End of configuration label End of Configuration ...

Страница 7: ...till active after the data is transmitted but the successive transmission of the same bar code is not allowed when the trigger switch is pressed again Trigger mode Auto scan mode 4 2 Good read beeper tone selection You can use this option to set frequency and or duration of the buzzer after successful reading Low Medium High Disable 4 3 Sound duration long 120 ms Medium 50 ms Short 20 ms Very shor...

Страница 8: ...e 39 Disable Codabar Enable Codabar Disable UPC EAN JAN Enable UPC EAN JAN Disable ITF 2 of 5 Enable ITF 2 of 5 Disable Chinese Post Code Enable Chinese Post Code Disable Code 128 Enable Code 128 Disable Code 93 Enable Code 93 Disable EAN 128 Enable EAN 128 Disable MSI Enable MSI Disable Baracoda 2004 Page 7 22 ...

Страница 9: ...BC BL BLR2604 Programming Guide IATA Enable IATA Disable INDUSTRY 25 Enable INDUSTRY 25 Disable Italian Pharmacy Enable Italian Pharmacy Disable End of Configuration Baracoda 2004 Page 8 22 ...

Страница 10: ...GIT Calculate and Transmit Calculate but not Transmit No CONCATENATION Enable Disable IInterleaved 2 of 5 parameters setting Examples Felting length 4 to 8 digits LENTGTH Scan Start of configuration È Min È 0 È 4 È set max È 0 È 8 È set È End of configuration MAX Min Set CHECK DIGIT No Calculate and Transmit Calculate but not Transmit End of Configuration Baracoda 2004 Page 9 22 ...

Страница 11: ...t of configuration È Min È 0 È 4 È set max È 0 È 8 È set È End of configuration CHECK DIGIT NO Calculate and Transmit Calculate but not Transmit Codabar Monarch parameters setting START STOP CHARACTER TRANSMISSION No A B C D DC1 DC4 a t b n c d e CONCATENATION Enable Disable End of Configuration Baracoda 2004 Page 10 22 ...

Страница 12: ...onfiguration UPC EAN JAN parameters setting FORMAT All EAN 8 or EAN 13 UPC A and EAN 13 UPC A and UPC E UPC A UPC E EAN 13 EAN 8 ADDENDUM NO 5 Characters 2 Characters 2 or 5 Characters FORCE UPC E TO UPC A FORMAT Yes No Baracoda 2004 Page 11 22 ...

Страница 13: ... Programming Guide FORCE UPC A TO EAN 13 FORMAT Yes No TRANSMIT UPC A LEADING CHARACTER Yes No TRANSMIT UPC A CHECK DIGIT Yes No TRANSMIT UPC E LEADING CHARACTER Yes No End of Configuration Baracoda 2004 Page 12 22 ...

Страница 14: ... Yes No TRANSMIT EAN 8 CHECK DIGIT Yes No Code 128 parameters setting FNC 2 CONCATENATION Enable Disable CHECK DIGIT No Calculate but not Transmit Calculate and Transmit UCC EAN128 parameters setting The character FNC1 can be transmitted or not using these codes FNC1 Character Transmitted FNC1 not Transmitted End of Configuration Baracoda 2004 Page 13 22 ...

Страница 15: ...in È 0 È 4 È set max È 0 È 8 È set È End of configuration MAX Min Set Msi Plessy setting Scan Start of configuration È Min È 0 È 4 È set max È 0 È 8 È set È End of configuration MAX Min Set Double Check digit Calculate but not Transmitted No Calculate but only first one Transmitted Calculated and both Transmitted End of Configuration Baracoda 2004 Page 14 22 ...

Страница 16: ...alian pharmacy parameters setting TRANSMIT A CHARACTER Yes No Barcode length setting CODE 39 LENGTH SETTING MAX MIN CODE 93 LENGTH SETTING MAX MIN CODE 128 LENGTH SETTING MAX MIN CODABAR LENGTH SETTING MAX MIN SET End of Configuration Baracoda 2004 Page 15 22 ...

Страница 17: ...g Guide Start of Configuration ISBN ISSN conversion The function convents the UPC EAN codes appearing on books and magazine not ISBN ISSN format ACTIVE ISBN ISSN INACTIVE ISBN ISSN End of Configuration Baracoda 2004 Page 16 22 ...

Страница 18: ...nable full ASCII code 39 option before you start 3 Read the Set label to set your choice into memory 6 2 Barcode identifier code selection The scanners can transmit max 2 digit barcode identifier code for different types of barcodes Use the labels to choose transmit or not transmit predefined barcode identifier code ID s are listed on section 1 Enable Disable 6 3 Barcode identifier code setting Ea...

Страница 19: ...BC BL BLR2604 Programming Guide Code 93 MSI INDUSTRY 25 IATA Set End of Configuration Baracoda 2004 Page 18 22 ...

Страница 20: ...ation NUL ENQ Up SOH Ins ACK Down STX Del BEL Left ETX Home BS Backspace EOT End HT TAB LF Enter num DLE 5 num VT Right DC1 F1 FF PgUp DC2 F2 CR Enter DC3 F3 SO PgDn DC4 F4 SI shift L NAK F5 SYN F6 GS ESC ETB F7 RS Ctl L CAN F8 US Alt L EM F9 SP SUB F10 ESC F11 Baracoda 2004 Page 19 22 ...

Страница 21: ...BC BL BLR2604 Programming Guide FS F12 0 1 2 3 4 5 6 7 8 9 A B I C J D K Baracoda 2004 Page 20 22 ...

Страница 22: ...BC BL BLR2604 Programming Guide E L F M G N H O P W Q X R Y S Z T U V e _ f g a h b i c j d k l s m t Baracoda 2004 Page 21 22 ...

Страница 23: ...BC BL BLR2604 Programming Guide n u o v p w q x r y z DEL End of Configuration Baracoda 2004 Page 22 22 ...