8
18007 IM_Banzai_12122012
Attn: Each time the blower is used, a simple test with the
Ground Fault Circuit Interrupter (GFCI) must be conducted.
1. Push the “Reset” button located on the GFCI receptacle, first to assure normal blower and GFCI operation.
2. Press “ I ” to switch on the blower.
3. Push the “Test” button located on the GFCI receptacle. The blower should go “OFF”.
4. Push the “Reset” button again. The blower should go “ON” again.
The indicator on the GFCI receptacle will be red whenever the “Reset” button is pressed.
If the blower remains “ON” when the “Test” button is pushed, the blower or GFCI is not working properly. If blower or
GFCI is not working properly, please call a qualified, certified electrician who can assess the situation.
Maintenance and Storage:
1. To keep the blower clean you can use a dry cloth or a cloth dampened with a neutral, non-inflammable, nontoxic cleaning
and sanitizing solution or pure water to wipe the surface of the blower.
2. You should not clean the blower with a chemical solution as this may damage the coating and plastic parts.
3. Never clean the blower in water.
4. Never store the blower outside. Keep it in a dry indoor place unreachable by children.
5. Regularly check the condition of the blower stakes. Damage to or deterioration of the stakes could result in the blower
becoming unstable which could result in serious injury.
6. Regularly check the condition of the power cord and GFCI. Damage to or deterioration of the cord or GFCI could cause a serious electrocution hazard. If the cord
or GFCI is damaged or deteriorated, immediately discontinue use of the blower and contact the manufacturer.
7. This blower with Auto-Reset Protector, if the motor over heated, the protector will trip to protect your safety. Turn off the blower and let it cool down. Then, you can
use it again. Please follow the instruction carefully to avoid any wrong operation that will cause overheating.
8. To keep the power cord in good condition, hand-supported product when carry the power cord, and do not twisting the cord, keep it dry and store it dry.
RESET
TEST
Indicator
ALL NEW MATERIAL. Surface Clean Only. Electrical ratings: 110-120VAC, 60Hz, 3.3A
NOTE:
The maximum wind speed for operations
of the inflatable shall be 20 mph.