background image

e

STATION

-

!

!

- End curr. (End current) :

 Set the final charging current at 

termination. 
   Auto; The process will be terminated when the charging current 
go to 1/10 of its initial value. Otherwise, the charge current will be 
decreased until the input value has been reached. (Auto, 
60~500mA)

- Tickle curr. (Trickle charge current) :

 Activate or deactivate the 

trickle charge after the termination of process. (Off, 50 ~ 300mA)

E n d  c u r r           :             A u t o
M a x   c a p a                 :                     1 0 0 %
S a f e t y   t i m e r         :               7 2 0 m i n
S a f e t y   t e m p         :                         5 0 C
Tr i c k l e   c u r r           :               1 0 0 m A

P b [   1   ]                       6 S ( 1 2 . 0 V )
  1 2 0 0 0 m A h              

C H A R G E

P b [   1   ]                       6 S ( 1 2 . 0 V )
  1 2 0 0 0 m A h              

C H A R G E

- 18 -

Using both OUTPUT-1 and OUTPUT-2

 To activate opposite output channel during the process is running on an output, just press 

‘CHANNEL’ button. The main menu screen or the program set-up screen will be shown for new 
output. Even the screen switch to new display, the process keeps on running at the other 
output. Connect the battery to new output channel, and select or set up suitable program by 
following the instruction. After finishing the setup, press ‘START/ENTER’ button for more than 
3 seconds to start the process at the output channel. Now, both output channels are running 
their own process.
 Remember both output channels have the circuit which is independent, but identical.

!

!

Discharging Pb battery

D c h g   c u r r                 :                       5 . 0 A
D c h g   v o l t                   :               D e f a u l t
D c h g   m o d e             :               N o r m a l
E n d   c u r r                     :             N o t   u s e
M a x  c a p a          :           1 0 0 %

D c h g   m o d e           :                 N o r m a l
E n d   c u r r                   :                        A u t o
M a x   c a p a                 :                       1 0 0 %
S a f e t y   t i m e r       :               7 2 0 m i n
S a f e t y   t e m p         :                           5 0 C

- Dchg. curr. (Discharge  ent) :

 Set the discharge current. (0.1 ~ 5.0A)

- Dchg. Volt (Discharge volt) :

 Set the final voltage per cell. The final voltage should not be under the 

voltage level that is recommended by the battery manufacturer to avoid deep discharging. (Default, 
1.40~1.80V/cell)

- Dchg. mode (Discharge mode) :

 Set the discharge mode.

  Normal; The charger will keep on discharging with the discharge current continuously until the discharge 
voltage has been reached.
  CV mode;  The discharging current will start to be decreased gradually until the end current which will 
be set up at next has been reached, when the voltage has been dropped to the final discharge voltage.

- End curr. (End current) :

 Set the final discharging current at termination. 

The end current should be 

less than the initial discharge current. 

 

   Auto; The process will be terminated when the discharge current go to 1/10 of its initial value. 
Otherwise, the discharge current will be decreased until the designated value has been reached. (Auto, 
60~500mA)

P b [   1   ]                       6 S ( 1 2 . 0 V )
  1 2 0 0 0 m A h          

DISCHARGE

P b [   1   ]                       6 S ( 1 2 . 0 V )
  1 2 0 0 0 m A h          

DISCHARGE

C h g  c u r r           :             5 . 0 A
C h g   v o l t                     :               D e f a u l t
C h g  m o d e        :         L i n e a r
E n d  c u r r           :             A u t o
M a x  c a p a         :           1 0 0 %

!

Содержание e-STATION BC8DX

Страница 1: ...t to commit modifications Copyright reserved Two identical and independent outputs with integrated balancer Charge current up to 9A discharge current up to 5A 1 to 8 series of LiIo LiPo LiFe 1 to 22 c...

Страница 2: ...acteristics by their chemistry You can select any one of them that you are going to process before the job For their specifications refer Warnings and safety notes section Maximum safety Delta peak se...

Страница 3: ...the main menu horizontally Switch the process data screen between graph informations and individual cell voltages during charging or discharging START ENTER button Commence the program by pressing thi...

Страница 4: ...e cut off level 2 5V cell or higher LiPo voltage level 3 7V cell max charge voltage 4 2V cell allowable fast charge current 1C or less discharge voltage cut off level 3 0V cell or higher LiFe voltage...

Страница 5: ...of the Lithium battery pack It may be composed of parallel and series connection mixed In parallel link the capacity of the battery pack is multiplied by the number of cells but the voltage remains sa...

Страница 6: ...Maximum capacity 50 150 Safety timer 10 9990 min Safety temp 20 80C CYCLE Cycle Mode Waste time 0 60 min No of cycles 1 10 times DISCHARGE Maximum capacity 50 150 Safety timer 10 9990 min Safety temp...

Страница 7: ...N UP UP DOWN DOWN UP UP DOWN DOWN UP UP DOWN DOWN UP UP DOWN DOWN UP UP End current Auto 60 500mA Maximum Capacity 50 150 Safety timer 10 9990 min Safety temp 20 80C DOWN DOWN UP UP DOWN DOWN UP UP DO...

Страница 8: ...button to move the cursor in vertical direction and use INC DEC buttons in horizontal direction By pressing STOP ESC button the screen goes to previous menu at any time 8 The first display e S TAT I...

Страница 9: ...he available letters The password can be any combination of 4 digits within those alphanumeric Locate the black mark to the desired character using INC or DEC buttons and press ENTER to input To move...

Страница 10: ...r 5 0A Chg mode Normal End curr Auto Chk time 10min Max capa 100 LiPo 1 6S 22 2V 3000mAh CHARGE You can choose a sub program to be performed by pressing MODE button there are CHARGE DISCHARGE and STOR...

Страница 11: ...by user But the battery which has been discharged deeply can be perceived the cell count incorrectly The charger will work on the cell count anyway during the check time But if the charger finds the w...

Страница 12: ...imum safety and 0 1 5 0A Dchg volt Discharge volt Set the final voltage per cell The final voltage should not be under the voltage level that is recommended by the battery manufacturer to avoid deep d...

Страница 13: ...battery before long term storage you can use this function also This is a safety feature programmed to protect the battery from over charging or deep discharging condition 50 120 Safety timer When you...

Страница 14: ...charged The cell count and capacity need to be matched with the battery Use UP DOWN buttons to scroll up and down the menu and change the value using INC DEC buttons when the pertinent field is blink...

Страница 15: ...for NiMH only Delicate The charger will detect a very small variation at delta peak voltage Some NiMH batteries which shows small voltage drop at peak need to be use this option Default If you do not...

Страница 16: ...d of discharge The default value is 0 90V cell 0 1 1 2V cell Charge to discharge discharge to charge cycles NiMH NiCd battery Cycle mode CHG DCHG No cycles 2T Waste time 10min NiMH 1 7S 8 4V 3000mAh C...

Страница 17: ...ith the parameters which were set at the screen The feeding current will be zero at every 30 seconds to have 3 seconds of waste time for higher charging efficiency This is programmed for charging Pb l...

Страница 18: ...circuit which is independent but identical Discharging Pb battery Dchg curr 5 0A Dchg volt Default Dchg mode Normal End curr Not use Max capa 100 Dchg mode Normal End curr Auto Max capa 100 Safety ti...

Страница 19: ...led to fit in the screen INC DEC INC DEC In volt The voltage of battery or DC power source which is being used as an input power supply for the charger Ext temp The temperature of battery is being pro...

Страница 20: ...vol 10 54V Ext temp 42C Chg time 52min Dchg time 0min Capacity 898mAh DAT GRP CYE CEL No Capacity Voltage 1 C 00000mAh 0 00V D 00000mAh 0 00V 2 C 00000mAh 0 00V D 00000mAh 0 00V DAT GRP CYE CEL No Vol...

Страница 21: ...nd cables carefully There is a short circuit at output Please check the charging leads or output cable of battery pack The voltage of input power drops below the limit There happens the malfunction at...

Страница 22: ...ry can deliver 60 amps of current for one hour 60Ax1hr 60Ah Nominal voltage V The nominal voltage of the battery pack can be determined as follows NiCd or NiMH multiply the total number of cells in th...

Страница 23: ...1 2 9 0 5 0 2 2 4 9 0 5 0 3 3 6 9 0 5 0 4 4 8 9 0 5 0 5 6 0 9 0 4 2 6 7 2 9 0 3 5 7 8 4 9 0 3 0 8 9 6 9 0 2 6 9 10 8 9 0 2 3 10 12 0 9 0 2 1 11 13 2 9 0 1 9 12 14 4 9 0 1 7 13 15 6 9 0 1 6 14 16 8 9...

Страница 24: ...Delicate 5 20mV adjustable Temperature cut off range 20 80C 68 176F Trickle charge current Off 50 300mA adjustable N A for Lixx Cycle count 1 10 times N A for Lixx Cycle cool off waste time 0 60 minu...