NOTE! PLUMBING:
Water outlet on left side as shown in illustration.
Placement of stopvalve:
because of moving parts
when adjusting the cistern’s height the stop valve
must be placed exactly as is shown on the illustration.
Stopvalves are turned as shown on drawing.
Concerning water;
finish with stop valve with 1/2”
external threads (G15). (Threads pointing up)
Drainpipe in floor:
Ø110 drainpipe without cuff is
finished 40 mm above floor.
NOTE! ELECTRICAL:
Electrical innstallation only for products with electrical
height adjustment.
Electrical outlet on right side as shown in illustration.
Electrical cable/ pipe is pulled 500 mm from wall
and placed 200 mm above finished floor and 100 mm
from the center of the cistern’s drain.
Electritian connects IP44-box aftrer the cistern is
installed. (IP44-box not included).
NOTE! ELECTRICAL:
This ONLY applies to 5970S2-EL with electrical
height-adjustment.
Finished floor
NOTE! CONSTRUCTION:
Loadtested untill 500 kg.
Min.: 48x198 board
Nailingstrips must be placed flush against wall material.
Nailing strips are indicated with shaded area.
1
2
(5/17)