Switches
Device Settings
1
2
3
4
5
6
7
8
Thermocouple, N-Type
ON
OFF
OFF
ON
Thermocouple, P-Type
ON
OFF
ON
OFF
Thermocouple, R-Type
ON
OFF
ON
ON
Thermocouple, S-Type
ON
ON
OFF
OFF
Thermocouple, T-Type
ON
ON
OFF
ON
Thermocouple, U-Type
ON
ON
ON
OFF
* Default configuration.
Address Mode
The SureCross wireless devices may use one of two types of addressing modes: rotary dial addressing or extended addressing. In
rotary dial address mode, the left rotary dial establishes the network ID and the right rotary dial sets the device ID. The wireless network
is restricted to a maximum of 16 devices.
Extended address mode uses a security code to "bind" Nodes to a specific Gateway. Bound Nodes can only send and receive informa-
tion from the Gateway to which they are bound. In extended address mode, wireless networks may contain up to 48 radio devices. For
more information on extended address mode, refer to the SureCross
™
Wireless I/O Network product manual.
The device ships in rotary dial address mode by default, with the DIP switch in the OFF position. To use extended address mode, change
the DIP switch to the ON position.
Thermocouple Type
Use DIP switches 5, 6, 7, and 8 to select the thermocouple type. The default position is the OFF position for all switches, setting the
thermocouple to a J-type thermocouple.
Temperature Units
Use the DIP switch to specify if the temperature is stored in degrees Fahrenheit or Celsius. The default position is OFF, setting the
temperature to Fahrenheit. For Celsius measurements, set this switch to the ON position.
Supported Thermocouple Types
The thermocouple Node is configured, by default, to use J-type thermocouples. The following thermocouples are available by configuring
the Node.
Thermocouple
Range °F
Range °C
Type B
212 to 3,272 °F
100 to 1,800 °C
Type C
32 to 4,208 °F
0 to 2,320 °C
Type E
-58 to 1,832 °F
-50 to 1,000 °C
Type J
-292 to 1,382 °F
-180 to 750 °C
Type K
-292 to 2,282 °F
-180 to 1,250 °C
Type L
-328 to 1,652 °F
-200 to 900 °C
Type N
32 to 2,192 °F
0 to 1,200 °C
Type R
32 to 2,912 °F
0 to 1,600 °C
Type S
32 to 2,642 °F
0 to 1,450 °C
Type T
-238 to 752 °F
-150 to 400 °C
Type U
-148 to 1,112 °F
-100 to 600 °C
Wiring Your SureCross
®
Device
Use the following wiring diagrams to first wire the sensors and then apply power to the SureCross devices.
SureCross Temperature Probe with DX80 Node
4
www.bannerengineering.com - tel: 763-544-3164
P/N 156525 rev. -