Radio
General
2.4 GHz Compliance
FCC ID UE300DX80-2400 - This device complies with FCC
Part 15, Subpart C, 15.247
ETSI/EN: In accordance with EN 300 328: V1.7.1 (2006-05)
IC: 7044A-DX8024
Spread Spectrum Technology
FHSS (Frequency Hopping Spread Spectrum)
Link Timeout
Gateway: Configurable via User Configuration Tool (UCT)
software
Node: Defined by Gateway
Radio range is with the 2 dB antenna that ships with the product. High-
gain antennas are available, but the range depends on the environment
and line of sight. To determine the range of your wireless network, perform
a Site Survey.
Interface
Indicators: Two bi-color LEDs
Buttons: Two
Display: Six character LCD
Wiring Access
Four PG-7, One 1/2-inch NPT, One 5-pin Euro-style male
connector
Inputs
Environmental
Discrete Inputs
Rating: See control drawing
Sample/Report Rates: DIP switch configurable
Discrete Input ON Condition
PNP: Greater than 8V
NPN: Less than 0.7V
Discrete Input OFF Condition (DX99 Models)
PNP: Less than 4.5V
NPN: Greater than 2.2V or open
Analog Input Rating (mA Models)
Rating for 4 to 20 mA models: 24 mA
Impedance: 20 Ohms
Analog Input 1 Sample/Report Rates: DIP switch configura-
ble
Analog Input 2 Sample/Report Rates: 1 second / 16 seconds
Accuracy: 0.1% of full scale +0.01% per °C
Resolution: 12-bit
Analog Input Rating (V Models)
Rating for 0 to 10V models: 10V
Impedance: 20 Ohms
Analog Input 1 Sample/Report Rates: DIP switch configura-
ble
Analog Input 2 Sample/Report Rates: 1 second / 16 seconds
Accuracy: 0.25% of full scale +0.01% per °C
Resolution: 12-bit
Ratings
IEC IP67, NEMA 4x
Operating Conditions
Operating Temperature: −40 to +70 °C
Operating Humidity: 95% max. relative (non-condensing)
Radiated Immunity: 10 V/m, 80-2700 MHz (EN61000-6-2)
Shock and Vibration
IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz
To verify the analog input's impedance, use an Ohm meter to measure the
resistance between the analog input terminal (AIx) and the ground (GND)
terminal.
Refer to the
SureCross DX80 Wireless I/O Network Product Manual
(p/n
132607) for installation and waterproofing instructions. Operating the devi-
ces at the maximum operating conditions for extended periods can short-
en the life of the device.
Certifications
DX99 Polycarbonate Housings
CSA: Class I, Division 1, Groups A, B, C, D (Ex ia IIC / AEx ia IIC T4 ) Certificate: CSA 2008243
LCIE/ATEX: Zone 0 (Category 1G), Temperature Class T4 (II 1 G / Ex ia IIC T4) Certificate: LCIE 08 ATEX 6098 X
Notes: Special Conditions for Safe Use imposed by Intrinsic Safety Certificate LCIE 08 ATEX 6098 X: Ambient temperature range is
-40°C to +70°C. SureCross
®
DX99 FlexPower devices can only be connected to Intrinsically Safe certified equipment or simple appara-
(p/n 141513). The device must only use a lithium battery manufactured by XENO, type XL-205F.
SureCross DX99 FlexPower Node (Polycarbonate Housing)
P/N 142496 Rev. F
www.bannerengineering.com - tel: 763-544-3164