background image

Switch configurable Node with two discrete inputs and two analog inputs (powered by external battery module only)

For additional information, updated
documentation, and accessories, re-
fer to Banner Engineering's website, 

www.bannerengineering.com/sure-
cross

.

The SureCross

®

 wireless system is a radio frequency network with integrated I/O that can oper-

ate in most environments and eliminate the need for wiring runs. DX99 wireless networks are
formed around a Gateway, which acts as the wireless network master device, and one or more
Intrinsically Safe Nodes.

• Wireless industrial I/O device with two selectable discrete inputs and two analog inputs
• FlexPower

®

 power input requires power from the DX81H Battery Supply Module

• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple Access

(TDMA) control architecture ensure reliable data delivery within the unlicensed Industrial, Sci-
entific, and Medical (ISM) band

• Transceivers provide bidirectional communication between the Gateway and Node, including

fully acknowledged data transmission

• Lost RF links are detected and relevant outputs set to user-defined conditions
• DX99 Polycarbonate housings are certified for use in Class I, Division 1, Groups A, B, C, D;

and Zone 0 (Category 1G) when properly installed in accordance with the National Electrical
Code, the Canadian Electrical Code, or applicable local codes/regulations

Model (0 to 20 mA)

Frequency

Boost Voltage Inputs and Outputs

DX99N9X2S2N0M2X0A2

900 MHz ISM Band

18V

Discrete Mode
Inputs: Two selectable discrete
Switch Power: Two, Configurable

Analog Mode
Inputs: Two selectable discrete, two
0 to 20 mA analog
Switch Power: One, Configurable

DX99N2X2S2N0M2X0A2

2.4 GHz ISM Band

DX99N9X2S2N0M2X0A1

900 MHz ISM Band

10V

DX99N2X2S2N0M2X0A1

2.4 GHz ISM Band

Model (0 to 10V)

Frequency

Boost Voltage Inputs and Outputs

DX99N9X2S2N0V2X0A2

900 MHz ISM Band

18V

Discrete Mode
Inputs: Two selectable discrete
Switch Power: Two, Configurable

Analog Mode
Inputs: Two selectable discrete, two
0 to 10V analog
Switch Power: One, Configurable

DX99N2X2S2N0V2X0A2

2.4 GHz ISM Band

DX99N9X2S2N0V2X0A1

900 MHz ISM Band

10V

DX99N2X2S2N0V2X0A1

2.4 GHz ISM Band

Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative.

WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death.
 This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.

SureCross DX99 FlexPower Node (Polycarbonate Housing)

 

 

P/N 142496 Rev. F

7/1/2013

0 142496

6

Содержание SureCross DX99 FlexPower Series

Страница 1: ...nstalled in accordance with the National Electrical Code the Canadian Electrical Code or applicable local codes regulations Model 0 to 20 mA Frequency Boost Voltage Inputs and Outputs DX99N9X2S2N0M2X0...

Страница 2: ...all your wireless sensor network components If installation instructions are not included in this datasheet refer to the product manual for detailed installation instructions For additional informatio...

Страница 3: ...ch settings for this device are all in the OFF position Analog Configuration Switch 2 OFF 10V Boost Models For analog configuration DIP switch 2 is in the OFF position factory default Analog configura...

Страница 4: ...minutes ON OFF ON Sample Report Rate 30 minutes ON ON OFF Modbus or UCT configured overrides DIP switches ON ON ON Analog IN 2 Discrete 1 and Discrete 2 are not powered from switched power terminals...

Страница 5: ...lexPower applications setting the report rate to a slower rate extends the battery life Warm Up Time The warm up time defines how long the device must power up the sensor before a stable sensor readin...

Страница 6: ...LCD remains on for an additional minute after the radio enters storage mode After a device has entered storage mode you must wait one minute before waking it During normal operation the SureCross rad...

Страница 7: ...t Rates 1 second 16 seconds Accuracy 0 25 of full scale 0 01 per C Resolution 12 bit Ratings IEC IP67 NEMA 4x Operating Conditions Operating Temperature 40 to 70 C Operating Humidity 95 max relative n...

Страница 8: ...ineering Corp if the destination country is not on this list Violating Warnings The manufacturer does not take responsibility for the violation of any warning listed in this document Make no modificat...

Отзывы:

Похожие инструкции для SureCross DX99 FlexPower Series