Replacement battery pack model number: BWA-BATT-002. For pricing and availability, contact Banner Engineering.
DX80 Integrated Battery Replacement
To replace the lithium "D" cell battery in any integrated housing model, follow these steps.
1. Remove the four screws mounting the face plate to the housing and remove the
face plate.
2. Remove the discharged battery and replace with a new battery. Only use a 3.6V
lithium battery from Xeno, model number XL-205F.
3. Verify the battery’s positive and negative terminals align to the positive and negative
terminals of the battery holder mounted within the case. The negative end is toward
the spring. Caution: There is a risk of explosion if the battery is replaced incorrectly.
4. After replacing the battery, allow up to 60 seconds for the device to power up.
When removing the battery, press the battery towards the negative terminal to compress
the spring. Pry up on the battery’s positive end to remove from the battery holder. Properly
dispose of your used battery according to local regulations by taking it to a hazardous
waste collection site, an e-waste disposal center, or other facility qualified to accept lithium
batteries.
As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or
expose them to high temperatures. Do not recharge, crush, disassemble, or expose the
contents to water.
Replacement battery model number: BWA-BATT-001. For pricing and availability, contact Banner Engineering.
DX99 Battery Replacement (DX99...B Housings)
To replace the lithium "D" cell battery in the metal housings with integrated batteries, follow these steps.
1. Unscrew the lid on the back side of the metal enclosure.
2. Remove the discharged battery and replace with a new battery. Only use a 3.6V lithium battery from
Xeno, model number XL-205F.
3. Verify the battery’s positive and negative terminals align to the positive and negative terminals of the
battery holder mounted within the case. The negative end is toward the spring. Caution: There is a
risk of explosion if the battery is replaced incorrectly.
4. Screw on the lid and tighten.
5. After replacing the battery, allow up to 60 seconds for the device to power up.
When removing the battery, press the battery towards the negative terminal to compress the spring. Pry up
on the battery’s positive end to remove from the battery holder. Properly dispose of your used battery ac-
cording to local regulations by taking it to a hazardous waste collection site, an e-waste disposal center, or
other facility qualified to accept lithium batteries.
As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or expose them to
high temperatures. Do not recharge, crush, disassemble, or expose the contents to water.
Replacement battery model number: BWA-BATT-001. For pricing and availability, contact Banner Engineering.
DX99 Battery Replacement (DX99...D Housings)
To replace the lithium "D" cell battery in the metal housings with integrated batteries, follow these steps.