Banner Sure Cross DX80N9X1SX-P16E Скачать руководство пользователя страница 8

Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: [email protected]

High-Speed Part Counting Solutions Guide

P/N b_4441878 Rev. B

© Banner Engineering Corp. All rights reserved

Local Register #

Description

Part Counting Node Information

1 + 10 

×

 (N − 1)

Part Count #1

2 + 10 

×

 (N − 1)

Part Count #2

3 + 10 

×

 (N − 1)

Current State of Counter #1

4 + 10 

×

 (N − 1)

Current State of Counter #2

5 + 10 

×

 (N − 1)

Parts per minute #1

6 + 10 

×

 (N − 1)

Parts per minute #2

7 + 10 

×

 (N − 1)

Connection Status

8 + 10 

×

 (N − 1)

Warning #1

9 + 10 

×

 (N − 1)

Warning #2

10 + 10 

×

 (N − 1)

User Configurable Report Rate Constant

ANY Warning Register

195–196

ANY Warning 1 and 2

Node Status

200–215

Node Connection Status

Warning Delta 1

216–247

User Configurable Warning PPM Thresholds

Resets

300–316

Register and Counter Resets

Register Reads from Gateways

317–332

Node 1–16 Current State 1 Reads

333–348

Node 1–16 Current State 2 Reads

349–364

Node 1–16 Count 1 High Word Reads

365–380

Node 1–16 Count 1 Low Word Reads

381–396

Node 1–16 Count 2 High Word Reads

397-412

Node 1–16 Count 2 Low Word Reads

Timers to reset Prior Counts

413–428

Node 1–16 Count 1 Timers

429–444

Node 1–16 Count 2 Timers

Prior Counts 

445–476

Prior report Counts for establishing PPM

Where N represents the DX80-P16 Node ID Number.

Содержание Sure Cross DX80N9X1SX-P16E

Страница 1: ...ltiple part counts with to up 16 wireless Performance Nodes The high speed asynchronous totalizing done by the DX80 P16E Node gives the ability to totalize up to 10 000 parts per second Monitoring the current state of part counting inputs along with parts per minute rates can be used to establish errors or inefficiencies in the system Warnings are generated based on user input and the part rate to...

Страница 2: ...LEDs on the radio flash four times after it binds to the DXM This Node is now bound as Node ID 1 Label the Node for future reference 7 On the DXM Press Back to return to the main menu 8 To bind additional DX80 P16Es select Bind to X and press Enter 9 On the second DX80 P16E Turn the left dial to 0 and the right dial to 2 10 Triple click the binding button to start binding Node 2 to its master radi...

Страница 3: ...is the correct choice and multiple appear attempt to connect to each one until you are successful 7 Upload the High Speed Part Counting script file by going to the Settings Scripting screen Click Upload Script and select the file 8 Select the uploaded file in the window to the right of the Upload Script button Click Add Selected to Startup the DXM will run this script every time it restarts 9 Save...

Страница 4: ... cloud permissions a On the Modify Multiple Registers screen select Change in the drop down list next to Cloud Permissions b In the drop down list to the right select Read for Cloud Permissions c Set the Starting Register to 1 and the Ending Register to the value equal to 10 Number of Nodes in the system for example set the ending register 160 for 16 Nodes d Click Change Registers on the bottom ri...

Страница 5: ...hanged If data is being pushed to the cloud set the Cloud Push Interval to 00 15 00 15 minutes 3 Set up the email and text messages SMS works only if the DXM has a cellular module Expand the Email Recipients and SMS Recipients to enter up to 10 email addresses and 10 phone numbers along with a custom message a Go to the Settings Mail and Messaging screen b All SMTP fields should remain set to thei...

Страница 6: ...the website with the DXM used in the field The DXM pushes data to the website which can be viewed at any time Refer to the Banner Connected Data Solutions Instruction Manual to review all the features available for monitoring comparing data and establishing warnings alarms on the website To access a demo version of the website please contact your local Banner distributor and follow the instruction...

Страница 7: ... Light The register number for the master light outputs is N 16 9 where N is the Node ID of the master light The example shows the setup for the Master Light on Node ID 10 10 16 9 169 Configuring Time Stamped Logging To setup time stamped logging follow these steps 1 Go to the Local Registers Modify Multiple Registers screen 2 Click Reset Form 3 From the SD Card Logging drop down list select Chang...

Страница 8: ... Warning 2 10 10 N 1 User Configurable Report Rate Constant ANY Warning Register 195 196 ANY Warning 1 and 2 Node Status 200 215 Node Connection Status Warning Delta 1 216 247 User Configurable Warning PPM Thresholds Resets 300 316 Register and Counter Resets Register Reads from Gateways 317 332 Node 1 16 Current State 1 Reads 333 348 Node 1 16 Current State 2 Reads 349 364 Node 1 16 Count 1 High ...

Отзывы: