Included with Model

The following items ship with the DX80 radios.

BWA-HW-002: DX80 Access Hardware Kit, containing four PG-7 plastic threaded plugs, four PG-7 nylon gland

fittings, four PG-7 hex nuts, one 1/2-inch NPT plug, and one 1/2-inch nylon gland fitting. (Not included with IP20

DX80...C models)

BWA-HW-001: Mounting Hardware Kit, containing four M5-0.8 x 25mm SS screws, four M5-0.8 x 16mm SS screws,

four M5-0.8mm SS hex nuts, and four #8-32 x 3/4" SS bolts

BWA-HW-003: PTFE tape

BWA-9O2-C (900 MHz) or BWA-2O2-C (2.4 GHz): Antenna, 2 dBd Omni, Rubber Swivel RP-SMA Male. (Not

included with Internal antenna models)

Quick Start Guide (128185 for DX80 Gateways or 152653 for MultiHop models)

MQDC1-506: 5-Euro (single ended) straight cable, 2m (Not included with FlexPower devices)

BWA-HW-011: IP20 Screw Terminal Headers (2 pack) (Included only with the IP20 DX80...C models)

Warnings

Install and properly ground a qualified surge suppressor when installing a remote antenna system. Remote antenna configurations installed without surge

suppressors invalidate the manufacturer's warranty. Keep the ground wire as short as possible and make all ground connections to a single-point ground system to ensure no

ground loops are created. No surge suppressor can absorb all lightning strikes; do not touch the Sure Cross

®

 device or any equipment connected to the Sure Cross device

during a thunderstorm.

Exporting Sure Cross

®

 Radios. It is our intent to fully comply with all national and regional regulations regarding radio frequency emissions. Customers who want to

re-export this product to a country other than that to which it was sold must ensure the device is approved in the destination country. A list of approved

countries appears in the Radio Certifications section of the product manual. The Sure Cross wireless products were certified for use in these countries using the antenna that

ships with the product. When using other antennas, verify you are not exceeding the transmit power levels allowed by local governing agencies. Consult with Banner

Engineering Corp. if the destination country is not on this list.

Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not

intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product

warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any

time. For the most recent version of any documentation, refer to: 

www.bannerengineering.com

©

 Banner Engineering Corp. All rights reserved.

Banner Engineering Corp. Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.

will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty

period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,

ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE

OF DEALING OR TRADE USAGE.

This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE

LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,

CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER

ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product

previously manufactured by Banner Engineering Corp.

 

 

Sure Cross

®

 Performance Node

 

www.bannerengineering.com - Tel: +1-763-544-3164

 

Содержание Sure Cross DX80N2X6S-P2

Страница 1: ...P2 900 MHz ISM Band IP67 NEMA 6 Inputs Four selectable discrete two 0 to 20 mA default or 0 to 10 V user configurable Outputs Four sourcing discrete two 0 to 20 mA DX80N2X6S P2 2 4 GHz ISM Band DX80 C...

Страница 2: ...nstructions are not included in the datasheet refer to the product manual for binding instructions 5 Observe the LED behavior to verify the devices are communicating with each other For two LED models...

Страница 3: ...A input allows you to determine when you have an error condition with the sensor A normal input reading between 4 and 20 mA indicates a functioning sensor whereas a value below 4 mA indicates an error...

Страница 4: ...Refer to the Modbus Register table for the I O number for each analog input Writing a four 4 to the Units parameter defines the units as 0 to 10V Writing a two 2 to the Units parameter defines the un...

Страница 5: ...x DOx Discrete OUT x GND Ground dc common connection PWR 10 to 30 V dc power connection RX Serial communication line for the Gateway No connection for Nodes TX Serial communication line for the Gatew...

Страница 6: ...t damage Do not exceed analog input ratings for analog inputs Only connect sensor outputs to analog inputs Analog Input Wiring 10 30 V dc Power Analog Input Wiring 4 20 mA 2 Wire Externally Powered Se...

Страница 7: ...de 16 Discrete IN 4 0 1 0 1 5 5 5 Node 16 Analog IN 1 mA V 0 0 0 0 20 0 10 0 0 65535 6 6 6 Node 16 Analog IN 2 mA V 0 0 0 0 20 0 10 0 0 65535 7 7 7 Node 16 Reserved 8 8 8 Node 16 Device Message 9 9 9...

Страница 8: ...ications Certifications for DX8x C External Wiring Terminal and DX8x E Models CSA Class I Division 2 Groups ABCD Class I Zone 2 AEx Ex nA II T4 Certificate 1921239 ATEX II 3 G Ex nA IIC T4 Gc Group II...

Страница 9: ...tion country is not on this list Any misuse abuse or improper application or installation of this product or use of the product for personal protection applications when the product is identified as n...

Отзывы: