8.11 Industrial Ethernet Tab
Figure 76: Industrial Ethernet Tab
The
Industrial Ethernet
tab of the Software allows configuration of the Virtual Status Outputs, which offer the same
functionality as
Status Outputs
(added on the
Equipment
tab) over the network (see
Status Output Signal Conventions
p. 50 and
on p. 50 for detailed information). Up to 64 Virtual Status Outputs can be added for any
configuration using Modbus/TCP, EtherNet/IP Input Assemblies, EtherNet/IP Explicit Messages, and PCCC protocols on
FID 1 Base Controllers and up to 256 Virtual Status Outputs can be added on FID 2 or later Base Controllers and SCR P-2
Safety Controllers. FID 2 or later Base Controllers and SCR P-2 Safety Controllers can also use PROFINET.
To access the
Industrial Ethernet
tab:
1. Click
Network Settings
.
2. Select
Enable Network Interface
.
3. Adjust any settings, if necessary. See
Network Settings: Modbus/TCP, Ethernet/IP, PCCC
4. Click
OK
.
Use the
Auto Configure
function, located on the
Industrial Ethernet
tab of the Software, to automatically configure the
Virtual Status Outputs to a set of commonly used functions, based on the current configuration. Click
in the
Function
column next to any of the
VOx
cells to add a Virtual Status Output manually. Functions of all Virtual Status Outputs can be
modified by clicking on the button that contains the name of the function of the Virtual Status Output or by clicking
Edit
under the
Properties
table when VOx is selected.