5.3 Set the Sensitivity
Use Sensitivity Selection to set the signal strength threshold.
1. Access Sensitivity Selection.
Action
Result
Triple-pulse the remote input.
T
T
T
T
T
The green power LED flashes slowly.
2. Select the desired signal threshold.
Action
Result
Pulse
s
TEACH Mode
1
T
Signal Strength Threshold = 1
2
T
T
T
Signal Strength Threshold = 1.13
3
T
T
T
T
T
Signal Strength Threshold = 1.25
4
T
T
T
T
T
T
T
Signal Strength Threshold = 1.5
5
T
T
T
T
T
T
T
T
T
Signal Strength Threshold = 2
6
T
T
T
T
T
T
T
T
T
T
T
Signal Strength Threshold = 5
7
T
T
T
T
T
T
T
T
T
T
T
T
T
Signal Strength Threshold = 6.5
8
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
Signal Strength Threshold = 7.5
The signal strength is set and
the green power LED on the
sensor flashes three times. The
sensor exits remote teach and
returns to run mode.