![Banner QS30LLPQ Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/banner/qs30llpq/qs30llpq_manual_3847944002.webp)
Excess Gain
With Supplied Target BRT-51X51BM
With Supplied Target BRT-TVHG-2X2
With Target BRT-2X2 (Optional)
1
10
100
1.0 m
3.3'
10 m
33'
100 m
330'
0.1 m
0.33'
1000
E
X
C
E
S
S
G
A
I
N
DISTANCE
with BRT-51X51BM
1
10
100
1.0 m
3.3'
10 m
33'
100 m
330'
0.1 m
0.33'
1000
E
X
C
E
S
S
G
A
I
N
DISTANCE
with BRT-TVHG2X2
1
10
100
1.0 m
3.3 ft
10 m
33 ft
100 m
330 ft
0.1 m
0.33 ft
1000
E
X
C
E
S
S
G
A
I
N
DISTANCE
with BRT-2X2
Overview
QS30LLP and QS30LLPC Series sensors are easy-to-use, high-performance laser sensors whose many configuration options make
them suitable for demanding applications. Each sensor features two identically configured outputs, one each NPN and PNP.
The compact housing has a large, easy-to-see bargraph display plus bright LEDs for easy configuration and status monitoring during
operation. The sensor can be side-mounted, using integral mounting holes, or front-mounted, via the 30 mm threaded barrel.
MODEL QS30LLP(Q) is configured using the Maximum Excess Gain SET procedure. It is useful for long-range applications and high
variations in contrast, such as beam-break applications where the target objects are larger than the beam. See
Maximum Excess Gain
SET - Model QS30LLP
on page 3 for more information.
MODEL QS30LLPC(Q) is configured using the Low-Contrast SET procedure. It is useful for small object detection and other applications
with small variations in contrast, such as yarn- or thread-break applications. See
Low-Contrast SET - Model QS30LLPC
on page 5 for
more information.
Yellow Output
Conducting
Indicator
Green Power ON
Indicator
Configuration
Push
Buttons
Switching
Threshold
Bargraph
Display
SETUP Status
Indicators:
Delay
Dark Operate
Light Operate
Figure 1. Model QS30LLP Features
Yellow Output
Conducting
Indicator
Green Power ON
Indicator
Configuration
Push
Buttons
Switching
Threshold
Bar Graph
Display
SETUP Status
Indicators:
Delay
Dark Operate
Light Operate
Figure 2. Model QS30LLPC Features
Sensor Configuration
Sensor configuration is accomplished using the SET and SETUP modes. After SET mode has defined the sensing parameters, SETUP
mode may be used to add an OFF-delay or change the light/dark operate status. Manual Adjust may be used to fine-tune the thresholds.
Two push buttons, “+” and “-”, may be used to access and set sensing parameters. In addition, the remote wire also may be used for
some procedures (see below).
WORLD-BEAM QS30 LLP and LLPC
2
www.bannerengineering.com - tel: 763-544-3164
P/N 112355 Rev. C