Q4X
–
Set Teach Mode
The Q4X has 5 teach modes, Two Point Teach (
2-Pt
), Background Suppression (
BGS
), Foreground Suppression (
FGS
),
Dynamic Teach (
DYn
), and Dual Mode (
duAL
). These can be accessed with the following steps
1. Press MODE for 2 seconds ("out" will show in display, press + to get to “tch”)
2. Click SELECT / TEACH
3. Click + / - until the desired teach mode appears on the display (see above for abbreviated names)
4. Click SELECT/TEACH to select mode
5. Press and Hold SELECT/TEACH for 3 seconds to exit menu and return to run mode.
Q4X-TWO POINT TEACH
(“2
-
pt” MODE on sensor)
Sets a single switch point midway between two targets
TO PROGRAM THE SENSOR FOR THE APPLICATION
1.
Press TEACH for longer than 2 seconds:
2.
The display will flash between SEt and 1St.
3.
Focus laser on target
4.
Press SELECT / TEACH to teach first point
5.
The display will flash between SEt and 2nd.
6.
Place 2nd part under laser.
7.
Press SELECT / TEACH to teach second point
THE DISPLAY WILL FLASH THE SWITCH POINT THEN
THE SENSOR WILL RETURN TO RUN MODE
Q4X-BACKGROUND SUPPRESSION
(“BGS” MODE)
switch point set based on the position of the background
TO PROGRAM THE SENSOR FOR THE APPLICATION
1. Press TEACH for longer than 2 seconds
2. Focus laser on target (part)
3. Press SELECT / TEACH to teach the
part position
THE DISPLAY WILL FLASH THE SWITCH POINT THEN
THE SENSOR WILL RETURN TO RUN MODE
Q4X-WINDOW DETECTION
(“FGS” MODE on sensor)
Sets a window around a target.
TO PROGRAM THE SENSOR FOR THE APPLICATION
1. Press TEACH for longer than 2 seconds
2. Focus laser on target (part)
3. Press SELECT / TEACH to teach the
part position
THE DISPLAY WILL FLASH THE SWITCH POINT THEN
THE SENSOR WILL RETURN TO RUN MODE
Q4X-Co Distance Detection
(“DuAL” MODE on sensor)
Sensor will switch off at less than 75% of
reference intensity and distance (Teach reference target on fixture (on / 100)
TO PROGRAM THE SENSOR FOR THE APPLICATION
1. Press TEACH for longer than 2 seconds (sensor
will flash between SEt and on)
2. Focus laser on surface that is fixed where the
object will pass through
3. Press SELECT / TEACH to teach 100% intensity,
display will flash and read 100P
THE SENSOR WILL RETURN TO RUN MODE