Output Registers Register
Description
Values
Output
7941
Holds the latched statuses of the inputs. This register is designed to be
cleared by the master upon receipt. If the register is not cleared, the
status will be cleared by the timeout (default 1000 ms) defined in register
8812.
0 = None activated
1 = Primary activated
2 = Secondary activated
3 = Both activated
Output Status
7942
Holds the real time status of the inputs.
Secondary Input Operation—Enabling one input as the secondary input allows separate use of the other input. For example,
use the primary input in a standard pick-to-light application and the secondary input as a call for parts. The secondary input
has a different logic table.
Logic table for secondary input
Job Input Logic
Touch or Sensor Not Activated
Touch or Sensor Activated
Not Active (0)
Wait State
Secondary Acknowledge State
Active (Non 0)
Job State
The indicator in the device is fully customizable. A variety of colors, animations, and intensities are available to customize
the device for any application or system.
Registers
Description
Values
6200 (in Basic Mode) or
6304, 6305, 6315, 6316,
6326, 6327, 6337, 6338,
6348, and 6349 (in State
Mode)
Customize the intensity of the
indicator
0 = High
1 = Medium
2 = Low
3 = Off
6202
Customize the sensitivity of the touch
button
0—A more deliberate touch is needed to active the touch output. Useful to
avoid accidental triggers, such as in areas where water is present.
1—Balanced sensitivity (default setting)
2—A less deliberate touch is need to active the touch output. Useful for faster
operation or when operators are wearing gloves.
2.3 7-Segment Display Operation
The display in the device is fully customizable, including both the digits and decimal points.
Registers
Description
Values
8703 through 8799
Customizable 3-digit, 7-segment display
•
In Primary operation, the values are right justified and null terminated. See Appendix for available characters. Note that
upper case and lower case are differentiated and some representations are limited by the nature of the 7-segment
display. (ASCII encoded)
•
In Secondary operation, decimals stored in register 8703 and show on the display. (decimal encoded)
PTL110S Pick-To-Light Devices