Banner MINI-BEAM Expert Series Скачать руководство пользователя страница 2

Glass Fiber Optic Models

Model1

Sensing Mode

Range or Focus

Supply Voltage

Output Type

SME312F

Glass Fiber Optic, 880 nm infrared

Range varies by sensing mode and
fiber optics used

10 V dc to 30 V dc

Bipolar NPN/PNP

SME312FV

Glass Fiber Optic, Visible red, 650 nm

SME312FVG

Glass Fiber Optic, Visible green, 525 nm

SME312FVB

Glass Fiber Optic, Visible blue, 475 nm

SME312FVW

Glass Fiber Optic, Visible white, 450–650 nm

Plastic Fiber Optic Models

Model1

Sensing Mode

Range or Focus

Supply Voltage

Output Type

SME312FP

Plastic Fiber Optic, Visible red, 650 nm

Range varies by sensing mode and
fiber optics used

10 V dc to 30 V dc

Bipolar NPN/PNP

SME312FPG

Plastic Fiber Optic, Visible green, 525 nm

SME312FPB

Plastic Fiber Optic, Visible blue, 475 nm

SME312FPW

Plastic Fiber Optic, Visible white, 450–650 nm

Overview

Amber output
indicator LED

Bi-color green/red
indicator LED

MINI-BEAM

®

 Expert

 is a complete family of sensors, all housed in the

popular, robust and compact rectangular housing. Their large push button

and easy-to-see indicators provide easy configuration, alignment, and

monitoring during use.

Status Indicators

Normal sensor operation is called RUN mode. Sensor configuration (setting the sensitivity threshold and selecting output

ON and OFF conditions) is performed in TEACH mode. The two LED indicators (bi-color green/red and amber) have distinct

roles in the two operation modes. If contrast is marginal, the bi-color indicator will flash green to indicate instability. If this

occurs, reconfigure or realign the sensor, or clean the sensor or fiber lenses.

The Signal Strength indicator is Banner’s exclusive AID

 (Alignment Indicating Device). Its pulse rate increases as the

received light signal strength increases (during programming). This feature simplifies accurate alignment during TEACH

mode, and gives a relative indication of sensing contrast between the light and dark conditions.

LED

RUN Mode

TEACH Mode

Solid green

Power is on

Flashing green

Sensed light level is approaching sensing

threshold3

Solid red

Sensor “sees” its own modulated light source; pulse rate is proportional to the

received light signal strength4

Amber on

Outputs conducting

Ready to TEACH output ON condition

Amber off

Outputs not conducting

Ready to TEACH output OFF condition

3 This is the Stability indicator, which signals when maintenance, realignment, or reconfiguration is needed during RUN mode.

4 The faster the pulse rate, the stronger the light signal.

 

 

MINI-BEAM Expert Series

2

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 68812 Rev. C

Содержание MINI-BEAM Expert Series

Страница 1: ...ible red 650 nm clear object 1 m 3 3 ft with supplied reflector Diffuse Models Model1 Sensing Mode Range or Focus Supply Voltage Output Type SME312D Diffuse Infrared 880 nm 380 mm 15 in 10 V dc to 30 V dc Bipolar NPN PNP SME312DV Diffuse Visible red 650 nm 1100 mm 43 in SME312W Divergent Diffuse Infrared 880 nm 130 mm 5 in Convergent Models Model1 Sensing Mode Range or Focus Spot Size at Focus Sup...

Страница 2: ...or configuration setting the sensitivity threshold and selecting output ON and OFF conditions is performed in TEACH mode The two LED indicators bi color green red and amber have distinct roles in the two operation modes If contrast is marginal the bi color indicator will flash green to indicate instability If this occurs reconfigure or realign the sensor or clean the sensor or fiber lenses The Sig...

Страница 3: ...ied with the fiber on each fiber end as shown in the drawing 2 While pressing the fiber ends firmly into the ports on the sensor front slide the U shaped retaining clip supplied with the sensor into the slot in the sensor s barrel until it snaps into place Plastic Fiber Installation Trimmed fiber control ends Plastic fiber emitter port Plastic fiber receiver port Gripper Unlock Lock Adapters for 0...

Страница 4: ...ondition and is ready for the output OFF condition Via remote line Present the first sensing condition and single pulse the remote line 3 Teach the second sensing condition and return to RUN mode Method Action Result Via push button Present the second sensing condition and click the push button If the teach is accepted the green LED is on or flashes if the signal is close to the switching threshol...

Страница 5: ... flashes red green this indicates a microprocessor memory error To clear the error re teach the sensor or cycle the power ON and OFF and re teach the sensor If this does not solve the problem or if it occurs frequently replace the sensor Banner Engineering Corp Limited Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following ...

Отзывы: