Banner MA3-4 Скачать руководство пользователя страница 6

Modulated  remote  sensors  require  specially 

designed cable for efficient sensor performance.  

Extension  cable  is  available  in  100  foot  (30m) 

lengths.

Extension Cable

used with the compression fittings, at 

right, to achieve maximum protection 

to sensor cables.  

I.D. = 5/16"; O.D. = 7/16".  

Accessories for High Performance Modulated Remote Sensors

PVC-6   

6 feet (1,8m)

PVC-30

 30 feet (9m)

Hookup of LR300 and PT300

Hookup of SP300D, SP300L, LP400WB, SP1000V

Hookup of SP320D

Sensor Hookup Diagrams for MA3-4 MICRO-AMP Modules 

(continued)

Remote sensor cables may be run up to 30 feet (9m) away from the MA3-4 

amplifier.  All sensor models are available from the factory with 30 feet of 

cable, installed as an option.
When  splicing  additional  cable  to  the  standard  6-1/2  foot  length,  it  is 

important to use a separate shielded cable for emitter and receiver wires.  

Combining emitter and receiver wires together in the same cable (even if 

the cable is shielded) will result in direct coupling of the emitter signal to 

the receiver leads.
This is called "cable crosstalk" and will not allow full amplifier sensitivity 

setting without an amplifier "lock on" situation, which appears as a con

-

tinuous LIGHT condition.  Banner offers 100 foot (30m) lengths of sensor 

extension cable (see below) which, if used for cable splicing, will minimize 

the chances for cable crosstalk.

IMPORTANT : Cable Splicing Information

WARNING

  MICRO-AMP

® 

Systems do NOT 

include the self-checking redundant circuitry neces

-

sary to allow their use in personnel safety applica

-

tions.  A sensor or amplifier failure or malfunction 

can result in either an energized or a de-energized 

output condition.

Never use this product as a sensing device for personnel protection.  Its 

use as a safety device may create an unsafe condition which could lead 

to serious injury or death.

Only MACHINE-GUARD and PERIMETER-GUARD Systems, and 

other systems so designated, are designed to meet OSHA and ANSI 

machine safety standards for point-of-operation guarding devices.  No 

other Banner sensors or controls are designed to meet these standards, and 

they must NOT be used as sensing devices for personnel protection.

Heavy  duty  PVC  tubing  used  to 

protect  sensor  cable  in  applications 

involving  moisture  and/or  corrosive 

materials.  I.D. = 1/4"; O.D. = 3/8".

Extension Cable

Model

ESC-100

RSC-100

SSC-100

EC300E-100

EC300R-100

EC320-100

Used on Sensor Models

# of
Wires

Wire Colors

White, Green, Shield

Red, Black, Shield

White, Green, Red, Black, 

Shield

White, Shield

Red, Shield

White, Shield, Red, Shield

PT200, PT250, PT400, 

SP300RL

LR200, LR250, LR400, 
SP300EL

SP300D, SP300L, LP400WB, 

SP1000V

 

LR300

 

PT300

 

SP320D

3

3

5

2

2

4

Banner Engineering Corp.     9714 10th Avenue No., Minneapolis, MN 55441     Telephone: (763) 544-3164     FAX (applications): (763) 544-3573

Cable Protection

AC-6   

6 feet (1,8m)

AC-30  

30 feet (9m)

This  is  mild-steel  flexible  tubing 

Содержание MA3-4

Страница 1: ...c at 10 milliamps Off state leakage current less than 1 microamp Model MA3 4P has the same specifications and performance as the MA3 4 amplifier except that the MA3 4P has complementary PNP outputs in place of the MA3 4 s NPN configuration P N 03341F3G Printed in USA ADJUSTMENT GAINadjustment single turnpotentiometer adjust with small flat blade screwdriver INDICATOR exclusiveBannerAlignmentIndica...

Страница 2: ...ate a very small and well defined effective beam for resolv ing small profiles increasing sensing repeatability or easing response time requirements Aperture model AP400 010 AP400 015 AP400 040 AP400 030R LR200 PT200 LR250 PT250 LR300 PT300 LR400 PT400 Temp range 40 to 100 C Housing material black Delrin Temp range 40 to 100 C Housing material black Delrin Temp range 40 to 80 C Housing material bl...

Страница 3: ...ed Cables are 6 1 2 feet 2m long 30 foot 9m cables available by special order Sensors for use with MA3 4 and MA3 4P Modulated Amplifiers Model SP300L is a remote retroreflective sensor with the same rugged design as the SP300EL RL described above Its useable range is from 6 inches to 15 feet 0 2 to 4 5m using the model BRT 3 retroreflector If the object that is to break the beam has a shiny surfac...

Страница 4: ...hes 96mm from its glass lenses As the excess gain curve illustrates the SP1000V has a very sharp drop off of gain beyond the focus point This feature makes it an excellent choice for detecting a small part which is only a fraction of an inch in front of another surface such as parts on a conveyor viewed from above It is also ideal for fill level detection and for precise positioning control in lie...

Страница 5: ... shield wire of a remote sensor is wired The shield wire is the uninsulated wire in each sensor cable Failure to connect the shield as shown may result in false operation of the amplifier When wiring emitters it is good practice to connect the positive wire first LEDs are sensitive to application of the wrong voltage and can easily be destroyed NOTE only one sensor may be connected to each MA3 4 a...

Страница 6: ...ze the chances for cable crosstalk IMPORTANT Cable Splicing Information WARNINGMICRO AMP SystemsdoNOT includetheself checkingredundantcircuitryneces sary to allow their use in personnel safety applica tions A sensor or amplifier failure or malfunction can result in either an energized or a de energized output condition Never use this product as a sensing device for personnel protection Its use as ...

Отзывы: